Comparison of Accuracy Verification Method for X-Ray CT

被引:0
|
作者
Matsuzaki, K. [1 ]
Sato, O. [1 ]
Fujimoto, H. [1 ]
Abe, M. [1 ]
Takatsuji, T. [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Cent 3,Umezono 1-1-1, Tsukuba, Ibaraki 3058563, Japan
关键词
X-ray CT; Dimensional measurement; Performance evaluation; Standardization;
D O I
10.1007/978-3-319-64943-6_43
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray computed tomography (X-ray CT) has been occupying indispensable position in geometrical and dimensional measurements in industry, which is capable of measuring both external and internal dimensions of industrial products. Since there have been no international standard for evaluating measuring performance of industrial X-ray CT, it is hard to compare the measurement accuracy of X-ray CT supplied by different manufacturers. Although evaluation procedures for conventional coordinate measuring machines (CMMs) have been proposed and standardized, they cannot be applied for X-ray CT as they are. A hole plate and a step cylinder are examined to see which is a more suitable material standard for evaluating the measurement performance of X-ray CT. Experimental result shows that the step cylinder reveals the effect of penetration length more apparently.
引用
收藏
页码:601 / 610
页数:10
相关论文
共 50 条
  • [41] A straightforward and analytical method for precise X-ray CT magnification correction
    Talebinezhad, Hossein
    Fischer, Ralf
    Shmatok, Andrii
    Prorok, Barton C.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2023, 82 : 338 - 349
  • [42] A fast method for simultaneous reconstruction and segmentation in X-ray CT application
    Dong, Yiqiu
    Wu, Chunlin
    Yan, Shi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2021, 29 (13) : 3342 - 3359
  • [43] An Analytical Method for Reducing Metal Artifacts in X-Ray CT Images
    Chen, Ming
    Xia, Dimeng
    Wang, Dan
    Han, Jingqi
    Liu, Zhu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2019, 2019
  • [44] A simple method for automated lung segmentation in X-ray CT images
    Zheng, B
    Leader, JK
    Maitz, GS
    Chapman, BE
    Fuhrman, CR
    Rogers, RM
    Sciurba, FC
    Perez, A
    Thompson, P
    Good, WF
    Gur, D
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1455 - 1463
  • [45] Scatter Correction Method by Temporal Primary Modulation in X-Ray CT
    Schoerner, Karsten
    Goldammer, Matthias
    Stierstorfer, Karl
    Stephan, Juergen
    Boeni, Peter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) : 3278 - 3285
  • [46] Individual modeling method of a bone based on the X-ray CT data
    Tokyo Institute of Technology, Dept. of Mech. and Environ. Info., Ookayama, Meguro-ku, Tokyo 152-8552, Japan
    不详
    不详
    JSME Int J Ser C, 2 (445-450):
  • [47] Individual modeling method of a bone based on the X-ray CT data
    Inou, N
    Koseki, M
    Suetsugu, T
    Maki, K
    Ujihashi, S
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 1999, 42 (02): : 445 - 450
  • [48] A single-image method for x-ray refractive index CT
    Mittone, A.
    Gasilov, S.
    Brun, E.
    Bravin, A.
    Coan, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09): : 3433 - 3440
  • [49] A new interpolation free method for X-ray CT image reconstruction
    Mitra, A
    Banerjee, S
    17TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2004, : 54 - 59
  • [50] STREAK REMOVAL METHOD FOR CT BASED DIGITAL X-RAY IMAGES
    MARGOSIAN, PM
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1982, 19 (01): : 76 - 80