Comparison of Accuracy Verification Method for X-Ray CT

被引:0
|
作者
Matsuzaki, K. [1 ]
Sato, O. [1 ]
Fujimoto, H. [1 ]
Abe, M. [1 ]
Takatsuji, T. [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Cent 3,Umezono 1-1-1, Tsukuba, Ibaraki 3058563, Japan
关键词
X-ray CT; Dimensional measurement; Performance evaluation; Standardization;
D O I
10.1007/978-3-319-64943-6_43
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray computed tomography (X-ray CT) has been occupying indispensable position in geometrical and dimensional measurements in industry, which is capable of measuring both external and internal dimensions of industrial products. Since there have been no international standard for evaluating measuring performance of industrial X-ray CT, it is hard to compare the measurement accuracy of X-ray CT supplied by different manufacturers. Although evaluation procedures for conventional coordinate measuring machines (CMMs) have been proposed and standardized, they cannot be applied for X-ray CT as they are. A hole plate and a step cylinder are examined to see which is a more suitable material standard for evaluating the measurement performance of X-ray CT. Experimental result shows that the step cylinder reveals the effect of penetration length more apparently.
引用
收藏
页码:601 / 610
页数:10
相关论文
共 50 条
  • [31] COMPARISON OF SINUS X-RAY AND CT SCAN IN CHILDREN WITH CHRONIC SINUSITIS
    MASSEY, EN
    GARCIA, DP
    CORBETT, ML
    SHEARER, LT
    EBERLY, SM
    LE, HT
    KARIBO, JM
    PENCE, HL
    NGUYEN, K
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (01) : 303 - 303
  • [32] A METHOD OF X-RAY REPRODUCTION OF THE NEGATIVE X-RAY FILM
    REST, A
    STROUD, L
    AMERICAN REVIEW OF TUBERCULOSIS, 1947, 55 (02): : 184 - 186
  • [33] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088
  • [34] Comparison of the diagnostic accuracy of X-ray and computed tomography in patients with wrist injury
    Etli, Ibrahim
    Kozaci, Nalan
    Avci, Mustafa
    Karakoyun, Omer Faruk
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (03): : 651 - 655
  • [35] A METHOD FOR IMPROVING DIGITAL IMAGE COMPARISON IN X-RAY TOPOGRAPHS
    TJAHJADI, T
    BOWEN, DK
    MATERIALS LETTERS, 1987, 5 (5-6) : 227 - 231
  • [36] Comparison of accuracy of scintimammography and X-ray mammography in the diagnosis of primary breast cancer
    Buscombe, J
    Cwikla, JB
    Kelleher, SM
    Parbhoo, SP
    Thakrar, DS
    Hinton, J
    Deery, AR
    Crow, J
    Hilson, AJW
    CLINICAL RADIOLOGY, 1998, 53 (11) : 860 - 860
  • [37] SIMULATION AND EXPERIMENTAL VERIFICATION OF X-RAY SPECTRA
    Deresch, A.
    Jaenisch, G. -R.
    Bellon, C.
    Warrikhoff, A.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B, 2010, 1211 : 535 - +
  • [38] SIMULTANEOUS EMISSION CT AND X-RAY TRANSMISSION CT USING COMPOSITE X-RAY AND GAMMA-RAY DETECTORS
    CLINTHORNE, NH
    ANTONUK, LE
    HUANG, W
    YORKSTON, J
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P100 - P101
  • [39] COMPARISON BETWEEN X-RAY AND ELECTRON EXCITATION IN X-RAY SPECTROMETRY
    GOMISCEK, S
    KOMAC, M
    ZEMEK, O
    MINING AND METALLURGY QUARTERLY, 1971, (2-3): : 177 - 182
  • [40] Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam
    Koch, George K.
    Hamilton, Adam
    Wang, Kelly
    Herschdorfer, Laura
    Lee, Kyu Ha
    Gallucci, German O.
    Friedland, Bernard
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (04)