Comparison of Accuracy Verification Method for X-Ray CT

被引:0
|
作者
Matsuzaki, K. [1 ]
Sato, O. [1 ]
Fujimoto, H. [1 ]
Abe, M. [1 ]
Takatsuji, T. [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Cent 3,Umezono 1-1-1, Tsukuba, Ibaraki 3058563, Japan
关键词
X-ray CT; Dimensional measurement; Performance evaluation; Standardization;
D O I
10.1007/978-3-319-64943-6_43
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray computed tomography (X-ray CT) has been occupying indispensable position in geometrical and dimensional measurements in industry, which is capable of measuring both external and internal dimensions of industrial products. Since there have been no international standard for evaluating measuring performance of industrial X-ray CT, it is hard to compare the measurement accuracy of X-ray CT supplied by different manufacturers. Although evaluation procedures for conventional coordinate measuring machines (CMMs) have been proposed and standardized, they cannot be applied for X-ray CT as they are. A hole plate and a step cylinder are examined to see which is a more suitable material standard for evaluating the measurement performance of X-ray CT. Experimental result shows that the step cylinder reveals the effect of penetration length more apparently.
引用
收藏
页码:601 / 610
页数:10
相关论文
共 50 条
  • [1] Determination and verification of the x-ray spectrum of a CT scanner
    Hassan, Ahmad Ibrahim
    Skalej, Martin
    Schlattl, Helmut
    Hoeschen, Christoph
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [2] STEREOTAXIC TARGET POINT VERIFICATION OF AN X-RAY AND CT LOCALIZER
    SERAGO, CF
    LEWIN, AA
    HOUDEK, PV
    GONZALEZARIAS, S
    HARTMANN, GH
    ABITBOL, AA
    SCHWADE, JG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03): : 517 - 523
  • [3] Experimental Comparison of Proton CT and Dual Energy X-Ray CT in Terms of Relative Stopping Power Accuracy
    Dedes, G.
    Dickmann, J.
    Wesp, P.
    Johnson, R.
    Pankuch, M.
    Bashkirov, V.
    Schulte, R.
    Landry, G.
    Parodi, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E127
  • [4] Optimization method for x-ray CT exposure
    Tsujioka, K
    Ida, Y
    Chikamatsu, H
    Goka, S
    Mori, Y
    Katada, K
    RADIOLOGY, 1996, 201 : 824 - 824
  • [5] Experimental Verification of Geometric Measurement Accuracy for Stereo X-Ray Imaging
    Miroshnychenko, S., I
    Volkov, E. V.
    2017 IEEE 37TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2017, : 349 - 352
  • [6] A comparison of x-ray detectors for mouse CT imaging
    Goertzen, AL
    Nagarkar, V
    Street, RA
    Paulus, MJ
    Boone, JM
    Cherry, SR
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5251 - 5265
  • [7] Prototype combines the classical X-RAY CT and dark-field X-Ray Method
    不详
    RADIOLOGIE, 2022, 62 (03): : 198 - 198
  • [8] Accuracy evaluation of ExacTrac X-ray Snap Verification for the oesophageal cancer radiotherapy
    Duan, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1457 - S1457
  • [9] Summary of dosimeter tests performed with different X-ray units and X-ray films -: the accuracy of the method
    Holmström, JE
    INSIGHT, 1999, 41 (01) : 31 - 33
  • [10] The method of high-accuracy 3D reconstruction for oblique X-ray CT images
    Yoshizawa, Satoshi
    Tanaka, Toshiyuki
    Kikuchi, Kazoo
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 146 - +