Comparison of DC Ramp and DC Step tests results on Hydro Generator Stators

被引:3
|
作者
Lamarre, Laurent [1 ]
David, Eric [2 ]
Nair, Abdelkader [2 ]
机构
[1] Hydroquebec IREQ, 1800 Boul Lionel Boulet, Varennes, PQ J3X 1S1, Canada
[2] ETS, Dept Mech Engn, Montreal, PQ H3C 1K3, Canada
关键词
DIELECTRIC RESPONSE;
D O I
10.1109/EIC.2009.5166392
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work aims at comparing results obtained from the DC Ramp test with the DC step test on the stator insulation of large hydro generators. Four cases of field measurements done on hydro generators are presented. Results are analyzed according to analytical solutions presented by the authors in recent publications for both methods. Quantities such as IR, PI, absorption current parameters and leakage currents are tabulated for each case and various aspects regarding respective advantages and complementarities pertaining to each method are discussed.
引用
收藏
页码:468 / +
页数:2
相关论文
共 50 条
  • [21] Comprehensive Comparison of Isolated High Step-up DC-DC Converters for Low Power Application
    Pourjafar, Saeed
    Afshari, Hossein
    Mohseni, Parham
    Husev, Oleksandr
    Matiushkin, Oleksandr
    Shabbir, Noman
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1149 - 1161
  • [22] Super Twisting based step-by-step observer for a DC series motor: experimental results
    Amet, Leonardo
    Ghanes, Malek
    Barbot, Jean-Pierre
    2013 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2013, : 814 - 819
  • [23] Simulation Model of the Step-up DC-DC Converter with Auto-Transformer and the Results of the Analysis of Operation Modes
    Korobkov, Dmitry V.
    Mikhaylov, Roman V.
    Volkov, Alexander G.
    2017 18TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM), 2017, : 594 - 597
  • [24] An Enhanced Operational Definition of Dielectric Breakdown for DC Voltage Step-up Tests
    Andersen, Allen
    Dennison, J. R.
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 433 - 436
  • [25] Experiment Results of Laboratory Tests of Electrical Starting System Powered by a DC Source
    Zharkov, Maksim A.
    Bachurin, Petr A.
    Kharitonov, Sergey A.
    Korobkov, Dmitry V.
    Sarakhanova, Regina Yu
    Simin, Vasiliy S.
    2016 17TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM), 2016, : 623 - 627
  • [26] Review and Comparison of Integrated Inductive-Based Hybrid Step-Up DC-DC Converter under CCM
    Zeng, Wen-Liang
    U, Chi-Wa
    Lam, Chi-Seng
    2019 IEEE 62ND INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2019, : 730 - 733
  • [27] Comparison CCEM-K8 of DC voltage ratio: Results
    Marullo-Reedtz, G
    Cerri, R
    Blanc, I
    Gunnarsson, O
    Williams, J
    Raso, F
    Kim, KT
    Frenkel, RB
    Zhang, XZ
    Katkov, AS
    Dziuba, R
    Parker, M
    Wood, BM
    Christian, LA
    Tarnow, E
    Mahajan, SK
    Singh, A
    Sakamoto, Y
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 419 - 423
  • [28] Comparison of Non-Insulated, High-Gain, High-Power, Step-Up DC-DC Converters
    Garcia, F. S.
    Pomilio, J. A.
    Spiazzi, G.
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 1343 - 1347
  • [29] Review and Comparison of Integrated Inductive-Based Hybrid Step-Down DC-DC Converter Under CCM Operation
    Chi-Wa, U.
    Zeng, Wen-Liang
    Lam, Chi-Seng
    2019 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2019), 2019, : 49 - 52
  • [30] Comparison of DAB and LLC DC-DC Converters in High-Step-Down Fixed-Conversion-Ratio (DCX) Applications
    Mukherjee, Satyaki
    Kumar, Ashish
    Chakraborty, Sombuddha
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (04) : 4383 - 4398