Background: The commonly preferred right internal jugular vein was investigated in terms of its dimensions, the relationship between its dimensions and anthropometric measures, and the outcomes of its cannulation in infants. Data regarding its position with respect to the carotid artery indicated anatomical variation. Aim: The aim of this study was to share our observations pertaining to the anatomy and position of the right internal jugular vein with respect to carotid artery using ultrasound and our experience with ultrasound-guided right internal jugular vein access in neonates and small infants. Materials and methods: A total of 25 neonates and small infants (<4000 g) undergoing ultrasound-guided central venous cannulation via right internal jugular vein within a 6-month period were included. Ultrasound-guided anatomical evaluation of the vein was used to obtain the transverse and anteroposterior diameters, the depth from skin and the position with respect to the carotid artery. Real-time ultrasound-guided central cannulation success rates and complication rates were also obtained. The patients were divided into two groups with respect to their weight in order to compare both the position and the dimensions of right internal jugular vein and cannulation performance in infants weighing Results: The position was lateral to the carotid artery in 84% of all infants and similar in both groups. The first-attempt success rates of cannulation were similar (70% vs 73.3%) in both groups, with an overall success rate of 88%. Conclusion: Right internal jugular vein revealed a varying position with respect to carotid artery with a higher rate of lateral position. The presence of such anatomical variation requires ultrasonographic evaluation prior to interventions and real-time guidance during interventions involving right internal jugular vein.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [1] Ultrasound-Guided Internal Jugular Vein Cannulation
    Ortega, Rafael
    Song, Michael
    Hansen, Christopher J.
    Barash, Paul
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (16):
  • [2] Ultrasound-Guided Internal Jugular Vein Cannulation
    Maslove, David
    Mihm, Frederick
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (08): : 796 - 796
  • [3] Absence of the Right Internal Jugular Vein During Ultrasound-Guided Cannulation
    Alagoz, Ali
    Tunc, Mehtap
    Sazak, Hilal
    Pehlivanoglu, Polat
    Gokcek, Atila
    Ulus, Fatma
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 212 - 214
  • [4] Ultrasound-guided internal jugular vein cannulation: Can an artery be missed?
    Singh, Gyaninder Pal
    Chauhan, Vikas
    Kapoor, Indu
    Kumar, Abhyuday
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2018, 34 (01) : 130 - 131
  • [5] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    WANG Yao
    WANG Gang
    GAO Chang-qing
    中华医学杂志(英文版), 2013, 126 (13) : 2414 - 2417
  • [6] Neonatologist-Performed Ultrasound-Guided Internal Jugular Vein Cannulation
    Thakur, Anup
    Modi, Manoj
    Kler, Neelam
    Garg, Pankaj
    INDIAN PEDIATRICS, 2023, 60 (01) : 72 - 74
  • [7] Seeing Is Believing: Ultrasound-Guided Internal Jugular Vein Cannulation Response
    Lamperti, Massimo
    Subert, Matteo
    Cortellazzi, Paolo
    Vailati, Davide
    Caldiroli, Dario
    ANESTHESIA AND ANALGESIA, 2012, 115 (06): : 1471 - 1471
  • [8] Improvement of internal jugular vein cannulation using an ultrasound-guided technique
    Slama, M
    Novara, A
    Safavian, A
    Ossart, M
    Safar, M
    Fagon, JY
    INTENSIVE CARE MEDICINE, 1997, 23 (08) : 916 - 919
  • [9] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    Wang Yao
    Wang Gang
    Gao Chang-qing
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2414 - 2417
  • [10] Improvement of internal jugular vein cannulation using an ultrasound-guided technique
    M. Slama
    A. Novara
    A. Safavian
    M. Ossart
    M. Safar
    J.-Y. Fagon
    Intensive Care Medicine, 1997, 23 : 916 - 919