Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery

被引:2
|
作者
Wang Yao [1 ]
Wang Gang [1 ]
Gao Chang-qing [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiovasc Surg, Beijing 100853, Peoples R China
关键词
ultrasonography; interventional; central venous; minimally invasive surgical procedures; robotic cardiac surgery; cardiopulmonary bypass; CENTRAL VENOUS ACCESS; SELDINGER TECHNIQUE; PUNCTURE;
D O I
10.3760/cma.j.issn.0366-6999.20123005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Robotic assisted minimally invasive cardiac sugery is a new technique that uses small port sites and peripheral vessel cannulation for cardiopulmonary bypass (CPB) has been used. The right internal jugular vein (IJV) is commonly used for intraoperative venous access to the central circulation and identified with an external landmark. Previous studies have demonstrated the superiority of ultrasound guidance over external landmark technique in anaesthetic and intensive care settings. The aim of the present study was to delineate the utility of ultrasound-guided cannulation of the IJV during establishment of peripheral CPB in robotic cardiac surgery. Methods We prospectively studied 296 adult patients undergoing ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery at our institute from January 2007 to October 2012 (ultrasound group). The success rate, the first attempt success rate, access time and the complication rate of ultrasound-guided method were compared with the landmark-guided method used for 302 historical control patients (landmark group). Results In the ultrasound group, 296 consecutive adult patients underwent ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery. In the landmark group, 302 patients underwent right IJV cannulation using the landmark-guided technique. The success rate and the first attempt success rate in the ultrasound group were significantly higher than that in the landmark group (100% vs. 88.1%, P<0.000 and 98.6% vs. 38.4%, P<0.000). Average access time in the ultrasound group was shorter than that in the landmark group ((6.3 +/- 13.6) seconds; interquartile range (4-62) seconds vs. (44.5 +/- 129.5) seconds; interquartile range (5-986) seconds). The complication rate in the ultrasound group was significantly lower than that in the landmark group (0.3% vs. 8.3%, P<0.000). Conclusion Compared with the landmark-guided approach, ultrasound-guided cannulation of the right IJV significantly improves success rate, decreases access time and reduces complication rate during establishment of peripheral CPB in robotic cardiac surgery.
引用
收藏
页码:2414 / 2417
页数:4
相关论文
共 50 条
  • [1] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    WANG Yao
    WANG Gang
    GAO Chang-qing
    [J]. 中华医学杂志(英文版), 2013, 126 (13) : 2414 - 2417
  • [2] Ultrasound-Guided Internal Jugular Vein Cannulation
    Ortega, Rafael
    Song, Michael
    Hansen, Christopher J.
    Barash, Paul
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (16):
  • [3] Ultrasound-Guided Internal Jugular Vein Cannulation
    Movahed, Mohammad Reza
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (08): : 796 - 796
  • [4] Ultrasound-guided internal jugular vein cannulation: Can an artery be missed?
    Singh, Gyaninder Pal
    Chauhan, Vikas
    Kapoor, Indu
    Kumar, Abhyuday
    [J]. JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2018, 34 (01) : 130 - 131
  • [5] Seeing Is Believing: Ultrasound-Guided Internal Jugular Vein Cannulation Response
    Lamperti, Massimo
    Subert, Matteo
    Cortellazzi, Paolo
    Vailati, Davide
    Caldiroli, Dario
    [J]. ANESTHESIA AND ANALGESIA, 2012, 115 (06): : 1471 - 1471
  • [6] Neonatologist-Performed Ultrasound-Guided Internal Jugular Vein Cannulation
    Thakur, Anup
    Modi, Manoj
    Kler, Neelam
    Garg, Pankaj
    [J]. INDIAN PEDIATRICS, 2023, 60 (01) : 72 - 74
  • [7] Improvement of internal jugular vein cannulation using an ultrasound-guided technique
    Slama, M
    Novara, A
    Safavian, A
    Ossart, M
    Safar, M
    Fagon, JY
    [J]. INTENSIVE CARE MEDICINE, 1997, 23 (08) : 916 - 919
  • [8] Improvement of internal jugular vein cannulation using an ultrasound-guided technique
    M. Slama
    A. Novara
    A. Safavian
    M. Ossart
    M. Safar
    J.-Y. Fagon
    [J]. Intensive Care Medicine, 1997, 23 : 916 - 919
  • [9] Absence of the Right Internal Jugular Vein During Ultrasound-Guided Cannulation
    Alagoz, Ali
    Tunc, Mehtap
    Sazak, Hilal
    Pehlivanoglu, Polat
    Gokcek, Atila
    Ulus, Fatma
    [J]. TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 212 - 214
  • [10] Needle and guidewire visualization in ultrasound-guided internal jugular vein cannulation
    Moak, James H.
    Lyons, Michael S.
    Wright, Stewart W.
    Lindsell, Christopher J.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (04): : 432 - 436