Ultrasound-guided anatomical evaluation and percutaneous cannulation of the right internal jugular vein in infants <4000 g

被引:11
|
作者
Uzumcugil, Filiz [1 ]
Yilbas, Aysun Ankay [1 ]
Akca, Basak [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Anesthesiol & Reanimat, TR-06230 Ankara, Turkey
来源
JOURNAL OF VASCULAR ACCESS | 2020年 / 21卷 / 01期
关键词
Central venous catheter; neonates; ultrasound; CROSS-SECTIONAL AREA; TRENDELENBURG POSITION; CATHETERIZATION; PRESSURE; ACCESS; BURNS;
D O I
10.1177/1129729819845620
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The commonly preferred right internal jugular vein was investigated in terms of its dimensions, the relationship between its dimensions and anthropometric measures, and the outcomes of its cannulation in infants. Data regarding its position with respect to the carotid artery indicated anatomical variation. Aim: The aim of this study was to share our observations pertaining to the anatomy and position of the right internal jugular vein with respect to carotid artery using ultrasound and our experience with ultrasound-guided right internal jugular vein access in neonates and small infants. Materials and methods: A total of 25 neonates and small infants (<4000 g) undergoing ultrasound-guided central venous cannulation via right internal jugular vein within a 6-month period were included. Ultrasound-guided anatomical evaluation of the vein was used to obtain the transverse and anteroposterior diameters, the depth from skin and the position with respect to the carotid artery. Real-time ultrasound-guided central cannulation success rates and complication rates were also obtained. The patients were divided into two groups with respect to their weight in order to compare both the position and the dimensions of right internal jugular vein and cannulation performance in infants weighing Results: The position was lateral to the carotid artery in 84% of all infants and similar in both groups. The first-attempt success rates of cannulation were similar (70% vs 73.3%) in both groups, with an overall success rate of 88%. Conclusion: Right internal jugular vein revealed a varying position with respect to carotid artery with a higher rate of lateral position. The presence of such anatomical variation requires ultrasonographic evaluation prior to interventions and real-time guidance during interventions involving right internal jugular vein.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [31] Novel maneuvers to increase the internal jugular vein diameter during ultrasound-guided cannulation
    Praveen Maheshwari
    Bradley Kelsheimer
    Parul Maheshwari
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 898 - 900
  • [32] In reply: Ultrasound-guided internal jugular vein cannulation: techniques to confirm guidewire location
    Aoyama, Kazuyoshi
    Takenaka, Ichiro
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (12): : 1345 - 1345
  • [33] In reply: Ultrasound-guided internal jugular vein cannulation: techniques to confirm guidewire location
    Kazuyoshi Aoyama
    Ichiro Takenaka
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2015, 62 : 1345 - 1345
  • [34] A simple maneuver for confirmation of the guidewire during ultrasound-guided internal jugular vein cannulation
    Aoyama, Kazuyoshi
    Takenaka, Ichiro
    Iwagaki, Tamao
    Sano, Haruhiko
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (07): : 839 - 840
  • [35] Ultrasound-guided cannulation of the internal jugular vein for dialysis vascular access in uremic patients
    Lin, BS
    Huang, TP
    Tang, GJ
    Tarng, DC
    Kong, CW
    NEPHRON, 1998, 78 (04): : 423 - 428
  • [36] Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation
    Hasan Dolu
    Sıtkı Goksu
    Levent Sahin
    Onder Ozen
    Levent Eken
    Journal of Clinical Monitoring and Computing, 2015, 29 : 177 - 182
  • [37] Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation
    Dolu, Hasan
    Goksu, Sitki
    Sahin, Levent
    Ozen, Onder
    Eken, Levent
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 177 - 182
  • [38] PERCUTANEOUS INTERNAL JUGULAR VEIN CANNULATION
    DAILY, PO
    GRIEPP, RB
    SHUMWAY, NE
    ARCHIVES OF SURGERY, 1970, 101 (04) : 534 - &
  • [39] In reply: Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Kazuyoshi Aoyama
    Ichiro Takenaka
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 364 - 364
  • [40] PERCUTANEOUS INTERNAL JUGULAR VEIN CANNULATION
    FREUND, H
    AYALON, A
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1974, 10 (06): : 674 - 675