External field calibration method for low temperature section of infrared radiation measuring equipment

被引:0
|
作者
Lu Xiaofei [1 ]
Zhang li [1 ]
Li Yi [1 ]
Zhao Hui [1 ]
机构
[1] Jiuquan Satellite Lanch Ctr, Jiuquan 732750, Peoples R China
关键词
calibration; infrared image; low temperature;
D O I
10.1117/12.2572860
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the process of using infrared radiation measuring equipment, it is generally required to calibrate the linear response of the linear response range of the infrared focal plane detector. The calibration process generally calculates the grayscale output value of the device by measuring the standard blackbody radiation source with different known temperatures, and calculates the linear response of the device by the fitting method. In the actual calibration process of the external field, since the calibration temperature of the blackbody radiation source cannot be set lower than the ambient temperature, the equipment cannot perform measurement calibration on the black body below the ambient temperature, resulting in the lower limit of the linear response interval of the device cannot be confirmed, lower than the environment. The extrapolation calibration of the temperature may have a large error and the error cannot be evaluated. In this paper, a calibration method for low temperature section of external field equipment is proposed. The experiment proves that the method has high calibration accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Background radiation compensation calibration method for film cooling infrared temperature measurement based on BP neural network
    Li, Yifan
    Liu, Cunliang
    Meng, Xianlong
    Fu, Song
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [42] Research on scene temperature calibration method for medical infrared temperature measurement components
    Wang, Xinsai
    Feng, Xiaoer
    Li, Mingming
    Fan, Weikai
    MIPPR 2019: PARALLEL PROCESSING OF IMAGES AND OPTIMIZATION TECHNIQUES; AND MEDICAL IMAGING, 2020, 11431
  • [43] Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below 0 degrees C
    Yoo, Yong Shim
    Kim, Bong-Hak
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2018, 29 (02) : 70 - 76
  • [44] Low-temperature infrared radiation thermometry at NMIJ
    Ishii, J
    Ono, A
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 657 - 662
  • [45] Low-temperature radiator for verification and calibration of radiation thermometers
    Zuev, A. V.
    Rozhkov, V. A.
    MEASUREMENT TECHNIQUES, 2013, 56 (07) : 805 - 808
  • [46] Method of Control and Linearization of Calibration Function for Reference Infrared Radiation Thermometer
    Hots, Nataliya
    2016 13TH INTERNATIONAL CONFERENCE ON MODERN PROBLEMS OF RADIO ENGINEERING, TELECOMMUNICATIONS AND COMPUTER SCIENCE (TCSET), 2016, : 308 - 311
  • [47] Low-temperature radiator for verification and calibration of radiation thermometers
    A. V. Zuev
    V. A. Rozhkov
    Measurement Techniques, 2013, 56 : 805 - 808
  • [48] A near-field bistatic radar cross section calibration method
    Marie, A. C.
    Pasquet, D.
    Maze-Merceur, G.
    Morvan, S.
    Bourdel, E.
    2007 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-12, 2007, : 4182 - +
  • [49] Study on the radiation-temperature measurement with infrared fiber at low temperature
    Yang, Wenku
    Yang, Tao
    Deng, Wenrong
    Hongwai Yu Haomibo Xuebao/Journal of Infrared and Millimeter Waves, 1996, 15 (05): : 379 - 385
  • [50] Preliminary Research on Calibration Equipment for Measuring Inhomogeneity of Magnetic Field of Medical Nuclear Magnetic Resonance
    Han, Bing
    Li, Chen
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2654 - +