External field calibration method for low temperature section of infrared radiation measuring equipment

被引:0
|
作者
Lu Xiaofei [1 ]
Zhang li [1 ]
Li Yi [1 ]
Zhao Hui [1 ]
机构
[1] Jiuquan Satellite Lanch Ctr, Jiuquan 732750, Peoples R China
关键词
calibration; infrared image; low temperature;
D O I
10.1117/12.2572860
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the process of using infrared radiation measuring equipment, it is generally required to calibrate the linear response of the linear response range of the infrared focal plane detector. The calibration process generally calculates the grayscale output value of the device by measuring the standard blackbody radiation source with different known temperatures, and calculates the linear response of the device by the fitting method. In the actual calibration process of the external field, since the calibration temperature of the blackbody radiation source cannot be set lower than the ambient temperature, the equipment cannot perform measurement calibration on the black body below the ambient temperature, resulting in the lower limit of the linear response interval of the device cannot be confirmed, lower than the environment. The extrapolation calibration of the temperature may have a large error and the error cannot be evaluated. In this paper, a calibration method for low temperature section of external field equipment is proposed. The experiment proves that the method has high calibration accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Measuring Systems for Thermometer Calibration in Low-Temperature Range
    Szmyrka-Grzebyk, A.
    Lipinski, L.
    Manuszkiewicz, H.
    Kowal, A.
    Grykalowska, A.
    Jancewicz, D.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2466 - 2476
  • [32] Methods for in-field user calibration of an inertial measurement unit without external equipment
    Fong, W. T.
    Ong, S. K.
    Nee, A. Y. C.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (08)
  • [33] Field Calibration Method of Camera for Measuring the Dimensions of Large Forging
    Liu, Wei
    Du, Jian
    Wang, Bangguo
    Jia, Xinghua
    Liu, Shuangjun
    Jia, Zhenyuan
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT II, 2010, 6425 : 285 - 295
  • [34] Average Infrared Brightness Temperature of Lunar Rough Surface in Field of View of High-Resolution Infrared Radiation Sounder and Application to Calibration
    Liu, Niutao
    Jin, Ya-Qiu
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [35] SPECTROSCOPIC METHOD FOR MEASURING SURFACE-TEMPERATURE THAT IS INDEPENDENT OF MATERIAL EMISSIVITY, SURROUNDING RADIATION SOURCES, AND INSTRUMENT CALIBRATION
    MARKHAM, JR
    BEST, PE
    SOLOMON, PR
    APPLIED SPECTROSCOPY, 1994, 48 (02) : 265 - 270
  • [36] Calculation of background radiation and temperature field of infrared target
    Wei, XZ
    Li, X
    Zhang, ZW
    Fu, YW
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 19 (02) : 139 - 141
  • [37] Infrared Thermography for Measuring Elevated Body Temperature: Clinical Accuracy, Calibration, and Evaluation
    Wang, Quanzeng
    Zhou, Yangling
    Ghassemi, Pejman
    McBride, David
    Casamento, Jon P.
    Pfefer, T. Joshua
    SENSORS, 2022, 22 (01)
  • [39] Measuring the temperature field of steady gas flow with infrared thermovision
    Lu, Jiaxiang
    Li, Guoxiang
    Liu, Yungang
    Gu, Hongzhong
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 1996, 17 (05): : 519 - 524
  • [40] Combined Radiation Calibration Method for Ground-Based Infrared Radiation Measurement System
    Yin Limei
    Qiao Bing
    Liu Junchi
    Huang Zhiguo
    Zhang Zhenduo
    Li Hongzhuang
    ACTA OPTICA SINICA, 2018, 38 (04)