External field calibration method for low temperature section of infrared radiation measuring equipment

被引:0
|
作者
Lu Xiaofei [1 ]
Zhang li [1 ]
Li Yi [1 ]
Zhao Hui [1 ]
机构
[1] Jiuquan Satellite Lanch Ctr, Jiuquan 732750, Peoples R China
关键词
calibration; infrared image; low temperature;
D O I
10.1117/12.2572860
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the process of using infrared radiation measuring equipment, it is generally required to calibrate the linear response of the linear response range of the infrared focal plane detector. The calibration process generally calculates the grayscale output value of the device by measuring the standard blackbody radiation source with different known temperatures, and calculates the linear response of the device by the fitting method. In the actual calibration process of the external field, since the calibration temperature of the blackbody radiation source cannot be set lower than the ambient temperature, the equipment cannot perform measurement calibration on the black body below the ambient temperature, resulting in the lower limit of the linear response interval of the device cannot be confirmed, lower than the environment. The extrapolation calibration of the temperature may have a large error and the error cannot be evaluated. In this paper, a calibration method for low temperature section of external field equipment is proposed. The experiment proves that the method has high calibration accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Research on Calibration Method of Infrared Test Equipment (Calibration Method of Infrared Radiometer and Infrared Thermal Imager)
    Guan, Wei
    Guo, Ling
    Fu, Li
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 1863 - 1868
  • [2] Calibration and application of radiometer for low-temperature infrared radiation source
    Shi, Qingfeng
    Gao, Yanze
    Li, Zhuo
    Shi, Rui
    AOPC 2021: INFRARED DEVICE AND INFRARED TECHNOLOGY, 2021, 12061
  • [3] TEMPERATURE CALIBRATION OF AN INFRARED RADIATION SOURCE
    SCHOLL, MS
    APPLIED OPTICS, 1980, 19 (21): : 3622 - 3625
  • [4] AN INDEPENDENT REFERENCE METHOD FOR THE CALIBRATION OF CO MEASURING EQUIPMENT
    GUGGENBERGER, J
    BRANDL, A
    LINDENMULLER, W
    STAUB REINHALTUNG DER LUFT, 1982, 42 (01): : 22 - 26
  • [5] AN INFRARED RADIOMETER FOR MEASURING SURFACE-TEMPERATURE IN THE FIELD .2. CALIBRATION AND PERFORMANCE
    HUBAND, NDS
    AGRICULTURAL AND FOREST METEOROLOGY, 1985, 34 (2-3) : 227 - 233
  • [6] Research on Calibration Method of Infrared Temperature Measurement System Near Room Temperature Field
    Cui, Shuanglong
    Xing, Jian
    FRONTIERS IN PHYSICS, 2022, 9
  • [7] Equipment for measuring thermal expansion in low temperature
    Iwanaga, Hiroshi
    Okuyama, Sadatoshi
    Yoshida, Nobuyuki
    Sumitomo Metals, 1998, 50 (03): : 83 - 84
  • [8] TEMPERATURE CALIBRATION OF LOW-TEMPERATURE INFRARED CELLS
    FORD, TA
    SETO, PF
    FALK, M
    SPECTROCHIMICA ACTA PART A-MOLECULAR SPECTROSCOPY, 1969, A 25 (09): : 1650 - &
  • [10] Infrared radiation method for measuring ice segregation temperature of artificially frozen soils
    Guoqing, Zhou
    Qi, Zhang
    Zhiwei, Xu
    Yang, Zhou
    INTERNATIONAL JOURNAL OF MINING SCIENCE AND TECHNOLOGY, 2012, 22 (01) : 35 - 40