Bearing capacity of reinforced foundation subjected to pull-out loading in 2D and 3D conditions

被引:7
|
作者
Nakai, Teruo [1 ]
Shahin, Hossain M. [1 ]
Zhang, Feng [1 ]
Hinokio, Masaya [2 ]
Kikumoto, Mamoru [1 ]
Yonaha, Shoko [1 ]
Nishio, A. [1 ]
机构
[1] Nagoya Inst Technol, Dept Civil Engn, Showa Ku, Nagoya, Aichi 4668555, Japan
[2] Gifu Univ, Dept Civil Engn, Gifu 5011193, Japan
关键词
Finite element analysis; Pile foundation; Reinforcement;
D O I
10.1016/j.geotexmem.2009.09.013
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Steel-framed structures like electricity transmission towers are subjected to great pull-out forces under strong wind conditions. This paper analyses how caisson foundations with reinforcement bars can increase the uplift bearing capacity of those structures. Model tests and numerical analyses in 2D and 3D are used to investigate how the bars' position and direction affect the behavior of the foundation under different load conditions. The test results show that reinforcements stemming diagonally downward from the bottom of the foundation are the most effective against uplift loading because they increase the structure's bearing capacity. However, this gain is less significant when inclined uplift forces are applied to the foundation. The higher the force inclination angle, the less efficient the design becomes. In that case, reinforcements that stem from the foundation's bottom are more effective than those stemming from the foundation's side. The numerical results accurately describe the experimental findings, since the simulations accounted appropriately for both the mechanical behaviors of the soil and the reinforcement as well as the frictional behavior between them. Furthermore, the results from the model tests and analyses carried out in 3D and 2D conditions are compatible. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:268 / 280
页数:13
相关论文
共 50 条
  • [31] 2D and 3D simulations of dynamic delamination in curved unidirectional CFRP laminates subjected to moment/axial combined loading
    Ata, Tamer Tahir
    Coker, Demirkan
    COMPOSITE STRUCTURES, 2021, 268
  • [32] Elastic Properties of Woven Reinforced Composites in 2D, 3D Simulations
    Tesinova-Vozkova, P.
    RECENT ADVANCES IN TEXTILE COMPOSITES, 2010, : 505 - 513
  • [33] 2D and 3D numerical simulations of reinforced embankments on soft ground
    Bergado, Dennes T.
    Teerawattanasuk, Chairat
    GEOTEXTILES AND GEOMEMBRANES, 2008, 26 (01) : 39 - 55
  • [34] Out of lab calibration of a rotating 2D Scanner for 3D mapping
    Koch, Rainer
    Boettcher, Lena
    Jahrsdoerfer, Maximilian
    Maier, Johannes
    Trommer, Malte
    May, Stefan
    Nuechter, Andreas
    VIDEOMETRICS, RANGE IMAGING, AND APPLICATIONS XIV, 2017, 10332
  • [35] Meso-level 3d numerical study on single fiber pull-out test for interface heterogeniety
    Zhang, Y. F.
    Zeng, X. R.
    MECHANICS AND ARCHITECTURAL DESIGN, 2017, : 162 - 168
  • [36] Effect of 3D, 4D, and 5D hooked-end type and loading rate on the pull-out performance of shape memory alloy fibres embedded in cementitious composites
    Dehghani, Ayoub
    Aslani, Farhad
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 273
  • [37] 2D and 3D on demand
    Philippi, Anne
    F & M; Feinwerktechnik, Mikrotechnik, Messtechnik, 1998, 106 (06): : 412 - 414
  • [38] 21/2D or 3D?
    Roth, S
    Küster, B
    Sura, H
    KUNSTSTOFFE-PLAST EUROPE, 2004, 94 (07): : 65 - 67
  • [39] From 2D to 3D
    Steven De Feyter
    Nature Chemistry, 2011, 3 (1) : 14 - 15
  • [40] Effects of shaft and wing diameters of a wing pile on bearing capacity and pull-out resistance under alternately cyclic vertical loading
    Urabe, Kokei
    Tokimatsu, Kohji
    Suzuki, Hiroko
    Asaka, Yoshiharu
    Journal of Structural and Construction Engineering, 2015, 80 (713): : 1113 - 1122