Analysis on Measuring Performance of Three Flicker Detecting Methods

被引:0
|
作者
Chen, Qing [1 ]
Jia, Xiufang [1 ]
Zhao, Chengyong [1 ]
机构
[1] N China Elect Power Univ, Key Lab Power Syst Protect & Dynam Secur Monitori, Minist Educ, Baoding 071003, Hebei Province, Peoples R China
关键词
Hilbert transform; short-term flicker severity P-st; square demodulation; Teager energy operator; voltage fluctuation and flicker; TRANSFORM;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Voltage fluctuation and flicker is an important aspect of power quality. The core of flicker analysis is to track the envelope of voltage signals and then calculate the short-term flicker severity P.,, which is the premise of flicker source location. This paper firstly derives the formulas of extracting flicker envelope of signals containing harmonics using Teager energy operator and Hilbert transform. Then the measuring performance of Teager energy operator, Hilbert transform and square demodulation of flicker with one frequency, multi-frequencies and with harmonics are analyzed. After extracting the flicker envelope, the flicker frequency and amplitude error, and short-term flicker severity P. error are calculated. Besides the relationships between amplitude error and frequency, P,, error and frequency with respect to these three methods are illustrated respectively. At last it is proved that Hilbert transform has the highest accuracy and stability than TEO and square demodulation with the increase of frequency.
引用
收藏
页码:1332 / 1338
页数:7
相关论文
共 50 条
  • [41] FOURIER METHODS IN FLICKER THEORY
    KELLY, DH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (11) : 1523 - &
  • [42] A COMPARISON OF THREE METHODS OF MEASURING PUPIL STATUS IN THE CLASSROOM
    Justman, Joseph
    Wrightstone, J. Wayne
    EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1951, 11 (03) : 362 - 367
  • [43] Convergent Validity of Three Methods for Measuring Postoperative Complications
    Fritz, Bradley A.
    Escallier, Krisztina E.
    Ben Abdallah, Arbi
    Oberhaus, Jordan
    Becker, Jennifer
    Geczi, Kristin
    McKinnon, Sherry
    Helsten, Dan L.
    Sharma, Anshuman
    Wildes, Troy S.
    Avidan, Michael S.
    ANESTHESIOLOGY, 2016, 124 (06) : 1265 - 1276
  • [44] Comparison of three methods of measuring surface area of soils
    de Jong, E
    CANADIAN JOURNAL OF SOIL SCIENCE, 1999, 79 (02) : 345 - 351
  • [45] Validity of Three Discount Methods for Measuring Perceived Usability
    Robertson, Ian
    Kortum, Philip
    JOURNAL OF USABILITY STUDIES, 2020, 16 (01) : 13 - 28
  • [46] A comparison of three methods for measuring patella malalignment in children
    Shin, AY
    Loncarich, DP
    Hennrikus, WL
    Case, SR
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 1998, 7 (04): : 303 - 306
  • [47] A comparison of three methods of measuring exercise in a field study
    Moore, SM
    Ruland, CM
    CIRCULATION, 1997, 96 (08) : 1060 - 1060
  • [48] A comparison of three methods of measuring plasma glycosylated hemoglobin
    Thevarajah, T. Malathi
    Hasrsah, Thuhairah
    Ismail, Aletza bt. Mohd
    Yean, Chew Yee
    ASIAN BIOMEDICINE, 2008, 2 (01) : 43 - 49
  • [49] Measuring postmortem glycated hemoglobin - A comparison of three methods
    Keltanen, Terhi
    Sajantila, Antti
    Valonen, Tiina
    Vanhala, Teija
    Lindroos, Katarina
    LEGAL MEDICINE, 2013, 15 (02) : 72 - 78
  • [50] A comparison of three methods of measuring the atmospheric coherence length
    Slavin, AC
    Wells, AL
    Fugate, RQ
    Fried, DL
    Drexler, JJ
    PROPAGATION AND IMAGING THROUGH THE ATMOSPHERE, 1997, 3125 : 241 - 249