Analysis on Measuring Performance of Three Flicker Detecting Methods

被引:0
|
作者
Chen, Qing [1 ]
Jia, Xiufang [1 ]
Zhao, Chengyong [1 ]
机构
[1] N China Elect Power Univ, Key Lab Power Syst Protect & Dynam Secur Monitori, Minist Educ, Baoding 071003, Hebei Province, Peoples R China
关键词
Hilbert transform; short-term flicker severity P-st; square demodulation; Teager energy operator; voltage fluctuation and flicker; TRANSFORM;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Voltage fluctuation and flicker is an important aspect of power quality. The core of flicker analysis is to track the envelope of voltage signals and then calculate the short-term flicker severity P.,, which is the premise of flicker source location. This paper firstly derives the formulas of extracting flicker envelope of signals containing harmonics using Teager energy operator and Hilbert transform. Then the measuring performance of Teager energy operator, Hilbert transform and square demodulation of flicker with one frequency, multi-frequencies and with harmonics are analyzed. After extracting the flicker envelope, the flicker frequency and amplitude error, and short-term flicker severity P. error are calculated. Besides the relationships between amplitude error and frequency, P,, error and frequency with respect to these three methods are illustrated respectively. At last it is proved that Hilbert transform has the highest accuracy and stability than TEO and square demodulation with the increase of frequency.
引用
收藏
页码:1332 / 1338
页数:7
相关论文
共 50 条
  • [21] METHODS FOR MEASURING STAFF NURSING PERFORMANCE
    GORHAM, WA
    NURSING RESEARCH, 1963, 12 (01) : 4 - 11
  • [22] 75 Hz flicker reduction procedures and the performance analysis
    Wang, Gang
    Ye, Wu
    Luo, Huiming
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 1998, 26 (07): : 16 - 20
  • [23] Comparison of three methods for measuring HF emissions
    Abbe, André
    Pisano, John
    Franz, Matthias
    Erzmetall: Journal for Exploration, Mining and Metallurgy, 1999, 52 (09): : 465 - 471
  • [24] Methods for measuring performance of LCoS microdisplays
    Wilson, Michael D.
    Journal of the Society for Information Display, 2001, 9 (03) : 229 - 232
  • [25] Measuring flicker with discrete Fourier transform
    Espel, P.
    Poletaeff, A.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 222 - 223
  • [26] A simulation study of three methods for detecting disease clusters
    Aamodt G.
    Samuelsen S.O.
    Skrondal A.
    International Journal of Health Geographics, 5 (1)
  • [27] Study on Indoor Detecting Methods and Performance of Shotcrete
    Shi Yan
    Li Jiazheng
    Yan Jianjun
    Peng Shangshi
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1217 - 1220
  • [28] Three simple methods of detecting malnutrition on medical wards
    Nightingale, JMD
    Walsh, N
    Bullock, ME
    Wicks, AC
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1996, 89 (03) : 144 - 148
  • [29] Comparison of heterochromatic flicker photometry and fundus autofluorescence as methods of measuring levels of macular pigment in vivo
    Hammond, CJ
    Liew, SM
    Spector, TD
    Mellerio, J
    Fitzke, FW
    Marshall, J
    van Kuijk, FJ
    Gilbert, CE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [30] Methods of Analysis of Information-Measuring System Performance under Fault Conditions
    Barabanova, E. A.
    Vishnevsky, V. M.
    Vytovtov, K. A.
    Semenova, O. V.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2023, 68 (SUPPL 3) : S368 - S376