Electrochemical DNA biosensor using a disposable electrochemical printed (DEP) chip for the detection of SNPs from unpurified PCR amplicons

被引:57
|
作者
Ahmed, Minhaz Uddin
Idegami, Koutarou
Chikae, Miyuki
Kerman, Kagan
Chaumpluk, Piyasak
Yamamura, Shohei
Tamiya, Eiichi
机构
[1] Japan Adv Inst Sci & Technol AIST, Sch Mat Sci, Nomi, Ishikawa 9231292, Japan
[2] Ishikawa Sunrise Ind Creat Org, Kanazawa, Ishikawa 9208203, Japan
[3] Chulalongkorn Univ, Sch Sci, Bangkok 10330, Thailand
关键词
D O I
10.1039/b615242b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we are reporting for the first time the elucidation of single nucleotide polymorphisms (SNPs) of clinically important alleles from consenting human subjects using a disposable electrochemical printed (DEP) chip in connection with differential pulse voltammetry (DPV) and a redox active molecule Hoechst 33258 [H33258, 2'-(4-hydroxyphenyl)-5-(4-methyl-1-piperazinyl)- 2,5'-bi(1H-benzimidazole)]. Post-PCR products were analyzed directly without any purification process. The aggregation of the DNA - H33258 complex causes a significant drop in the peak current intensity of H33258 oxidation. The phenomenon of DNA aggregation induced by H33258 in addition to changes in anodic current peak are used to detect SNPs. Since laborious probe immobilization was not required, our biosensor offers several benefits due to its simplicity and rapid response as a promising device for genetic analysis.
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [31] Disposable electrochemical biosensor with multiwalled carbon nanotubes - Chitosan composite layer for the detection of deep DNA damage
    Galandova, Julia
    Ziyatdinova, Guzel
    Labuda, Jan
    ANALYTICAL SCIENCES, 2008, 24 (06) : 711 - 716
  • [32] Detection of short oligonucleotide sequences using an electrochemical DNA hybridization biosensor
    Girousi, S.
    Kinigopoulou, V.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2010, 8 (04): : 732 - 736
  • [33] Detection of Short Oligonucleotide Sequences Using an Electrochemical DNA Hybridization Biosensor
    Girousi, Stella
    Kinigopoulou, Vasiliki
    2009 2ND INTERNATIONAL SYMPOSIUM ON APPLIED SCIENCES IN BIOMEDICAL AND COMMUNICATION TECHNOLOGIES (ISABEL 2009), 2009, : 167 - 170
  • [34] Developing a sensitive DNA biosensor for the detection of flutamide using electrochemical method
    Ali A. Ensafi
    Nahid Khademi Farfani
    Maryam Amini
    B. Rezaei
    Journal of the Iranian Chemical Society, 2017, 14 : 1325 - 1334
  • [35] Developing a sensitive DNA biosensor for the detection of flutamide using electrochemical method
    Ensafi, Ali A.
    Farfani, Nahid Khademi
    Amini, Maryam
    Rezaei, B.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1325 - 1334
  • [36] Electrochemical Detection of Interaction between Verbascum sp and DNA by using Disposable Biosensors
    Subak, H.
    Dalar, Abdullah
    Ozkan-Ariksoysal, D.
    BIOSENSORS 2016, 2017, 27 : 143 - 143
  • [37] Detection of Human Papillomavirus in Male and Female Urine by Electrochemical DNA Chip and PCR Sequencing
    Nilyanimit, Pornjarim
    Wanlapakorn, Nasamon
    Niruthisard, Somchai
    Pohthipornthawat, Natkrita
    Karalak, Anant
    Laowahutanont, Piyawat
    Phanuphak, Nittaya
    Gemma, Nobuhiro
    Poovorawan, Yong
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2013, 14 (09) : 5519 - 5525
  • [38] A Broad-Range Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes for Detection of Human Noroviruses
    Wang, Nan
    Pan, Guiying
    Guan, Shimin
    Rong, Shaofeng
    Wang, Dapeng
    Gao, Zhiyong
    Tian, Peng
    Li, Qianqian
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [39] Detection of the effective DNA protection by quinazolines using a DNA-Based electrochemical biosensor
    Ovádeková, R
    Jantová, S
    Labuda, J
    ANALYTICAL LETTERS, 2005, 38 (15) : 2625 - 2638
  • [40] Disposable Electrochemical Biosensor with Multiwalled Carbon Nanotubes-Chitosan Composite Layer for the Detection of Deep DNA Damage
    Julia Galandova
    Guzel Ziyatdinova
    Jan Labuda
    Analytical Sciences, 2008, 24 : 711 - 716