Electrochemical DNA biosensor using a disposable electrochemical printed (DEP) chip for the detection of SNPs from unpurified PCR amplicons

被引:57
|
作者
Ahmed, Minhaz Uddin
Idegami, Koutarou
Chikae, Miyuki
Kerman, Kagan
Chaumpluk, Piyasak
Yamamura, Shohei
Tamiya, Eiichi
机构
[1] Japan Adv Inst Sci & Technol AIST, Sch Mat Sci, Nomi, Ishikawa 9231292, Japan
[2] Ishikawa Sunrise Ind Creat Org, Kanazawa, Ishikawa 9208203, Japan
[3] Chulalongkorn Univ, Sch Sci, Bangkok 10330, Thailand
关键词
D O I
10.1039/b615242b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we are reporting for the first time the elucidation of single nucleotide polymorphisms (SNPs) of clinically important alleles from consenting human subjects using a disposable electrochemical printed (DEP) chip in connection with differential pulse voltammetry (DPV) and a redox active molecule Hoechst 33258 [H33258, 2'-(4-hydroxyphenyl)-5-(4-methyl-1-piperazinyl)- 2,5'-bi(1H-benzimidazole)]. Post-PCR products were analyzed directly without any purification process. The aggregation of the DNA - H33258 complex causes a significant drop in the peak current intensity of H33258 oxidation. The phenomenon of DNA aggregation induced by H33258 in addition to changes in anodic current peak are used to detect SNPs. Since laborious probe immobilization was not required, our biosensor offers several benefits due to its simplicity and rapid response as a promising device for genetic analysis.
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [21] Electrochemical detection of PCR amplicons using electroconductive polymer modified electrode and multiple nanoparticle labels
    Li, LL
    Cai, H
    Lee, TMH
    Barford, J
    Hsing, IM
    ELECTROANALYSIS, 2004, 16 (1-2) : 81 - 87
  • [22] A Sensitive Electrochemical Approach for Melamine Detection Using a Disposable Screen Printed Carbon Electrode
    Liao, Chen-Wei
    Chen, Yue-Ru
    Chang, Jen-Lin
    Zen, Jyh-Myng
    ELECTROANALYSIS, 2011, 23 (03) : 573 - 576
  • [23] Electrochemical gene detection using microelectrode array on a DNA chip
    Kobayashi, M
    Mizukami, T
    Morita, Y
    Murakami, Y
    Yokoyama, K
    Tamiya, E
    ELECTROCHEMISTRY, 2001, 69 (12) : 1013 - 1016
  • [24] Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor
    Abreu, FC
    Goulart, MOF
    Brett, AMO
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 913 - 919
  • [25] Detection of DNA Damage Induced by Hydroquinone and Catechol Using an Electrochemical DNA Biosensor
    Wang, Chuanhu
    Zhao, Jun
    Zhang, Dapeng
    Yang, Zhousheng
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2009, 62 (09) : 1181 - 1184
  • [26] Ultrasensitive detection of HIV DNA using an electrochemical biosensor with branched DNA amplification
    Ma, Mingyi
    He, Li
    Shi, Xiaoxue
    Wang, Yanchao
    Hai, Hong
    Wei, Xiaoping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (10):
  • [28] Electrochemical gene detection using multielectrode array DNA chip
    Choi, YS
    Park, DH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 44 (06) : 1556 - 1559
  • [29] Electrochemical DNA biosensor for the detection of TT and Hepatitis B virus from PCR amplified real samples by using methylene blue
    Meric, B
    Kerman, K
    Ozkan, D
    Kara, P
    Erensoy, S
    Akarca, US
    Mascini, M
    Ozsoz, M
    TALANTA, 2002, 56 (05) : 837 - 846
  • [30] Electrochemical detection of blood alcohol concentration using a disposable biosensor based on screen-printed electrode modified with Nafion and gold nanoparticles
    Luo, Peng
    Xie, Guoming
    Liu, Yi
    Xu, Huajian
    Deng, Shixiong
    Song, Fangzhou
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (11) : 1641 - 1647