Treatment of Fracture of the Calcaneus via Bone Axial X-Ray Image-Based Minimally Invasive Approach

被引:0
|
作者
Xiao, Jie [1 ]
Xin, Zengfeng [2 ]
Fu, Xiaojun [1 ]
Huang, Jiaqi [1 ]
Zhang, Bi [1 ]
Yu, Haiping [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Dept Orthoped, Jiande Branch,Sch Med, Hangzhou 311600, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Orthoped, Affiliated Hosp 2, Sch Med, Hangzhou 311000, Zhejiang, Peoples R China
关键词
21;
D O I
10.1155/2022/3012589
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To discuss the values of two bone axial X-ray image-based minimally invasive approach surgeries in the diagnosis and treatment of fracture of the calcaneus, 80 patients diagnosed with fracture of the calcaneus by bone axial X-ray examination were selected and divided equally into the minimally invasive longitudinal approach (MILA) group (40 cases) and the sinus tarsal approach (STA) group (40 cases). Besides, the duration of operation, the incidence of complications, the time-to-start weight training, and the American Orthopaedic Foot and Ankle Society (AOFAS) foot function scoring system between the patients in the two groups were compared. The results showed that the duration of operation and incidence of complications among the patients in the MILA group (42.87 +/- 5.12 minutes, 20%) were both superior to those among the patients in the STA group (60.43 +/- 7.31 minutes, 32.5%). The time-to-start weight training in the MILA group was 5.2 weeks, which was obviously shorter than that in the STA group (5.7 weeks). The difference in AOFAS scores between the two groups was not significant. The walking pavement score in the MILA group (4.2 +/- 0.37 points) was slightly higher than that in the STA group (3.3 +/- 0.45 points), and the differences demonstrated statistical meaning (P < 0.05). To sum up, the bone axial X-ray image is an essential examination method of diagnosing fracture of the calcaneus. The two minimally invasive methods both showed good clinical therapeutic effects. The operation of MILA was relatively shorter with fewer complications and is worthy of being promoted as an effective treatment method of fracture of the calcaneus.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [42] Segmentation uncertainty of vegetated porous media propagates during X-ray CT image-based analysis
    Jiang, Zhenliang
    Leung, Anthony Kwan
    Liu, Jianbin
    PLANT AND SOIL, 2024,
  • [43] Deformation Behavior Estimation of Aluminum Foam by X-ray CT Image-based Finite Element Analysis
    Yoshihiko Hangai
    Ryo Yamaguchi
    Shunya Takahashi
    Takao Utsunomiya
    Osamu Kuwazuru
    Nobuhiro Yoshikawa
    Metallurgical and Materials Transactions A, 2013, 44 : 1880 - 1886
  • [44] X-ray tomography image-based reconstruction of microstructural finite element mesh models for heterogeneous materials
    Huang, Ming
    Li, Yue-ming
    COMPUTATIONAL MATERIALS SCIENCE, 2013, 67 : 63 - 72
  • [45] A Monoscopic X-ray Image-Based Position Monitoring System for Liver Stereotactic Body Radiation Therapy
    Arumugam, S.
    Lee, M. T.
    Sidhom, M.
    Xing, A.
    Holloway, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E637 - E637
  • [46] DEMONSTRATING THE RISK OF IMBALANCED DATASETS IN CHEST X-RAY IMAGE-BASED DIAGNOSTICS BY PROTOTYPICAL RELEVANCE PROPAGATION
    Gautam, Srishti
    Hoehne, Marina M-C
    Hansen, Stine
    Jenssen, Robert
    Kampffmeyer, Michael
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [47] False dyssynchrony: Problem with image-based cardiac functional analysis using x-ray computed tomography
    Kidoh, Masafumi
    Shen, Zeyang
    Suzuki, Yuki
    Ciuffo, Luisa
    Ashikaga, Hiroshi
    Fung, George S. K.
    Otake, Yoshito
    Zimmerman, Stefan L.
    Lima, Joao A. C.
    Higuchi, Takahiro
    Lee, Okkyun
    Sato, Yoshinobu
    Becker, Lewis C.
    Fishman, Elliot K.
    Taguchi, Katsuyuki
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [48] Quantification of root water uptake in soil using X-ray computed tomography and image-based modelling
    Daly, Keith R.
    Tracy, Saoirse R.
    Crout, Neil M. J.
    Mairhofer, Stefan
    Pridmore, Tony P.
    Mooney, Sacha J.
    Roose, Tiina
    PLANT CELL AND ENVIRONMENT, 2018, 41 (01): : 121 - 133
  • [49] A statistical model of catheter motion from interventional x-ray images: application to image-based gating
    Panayiotou, M.
    King, A. P.
    Ma, Y.
    Housden, R. J.
    Rinaldi, C. A.
    Gill, J.
    Cooklin, M.
    O'Neill, M.
    Rhode, K. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7543 - 7562
  • [50] Long-Bone Fracture Detection in Digital X-ray Images Based on Concavity Index
    Bandyopadhyay, Oishila
    Biswas, Arindam
    Bhattacharya, Bhargab B.
    COMBINATORIAL IMAGE ANALYSIS, IWCIA 2014, 2014, 8466 : 212 - 223