Treatment of Fracture of the Calcaneus via Bone Axial X-Ray Image-Based Minimally Invasive Approach

被引:0
|
作者
Xiao, Jie [1 ]
Xin, Zengfeng [2 ]
Fu, Xiaojun [1 ]
Huang, Jiaqi [1 ]
Zhang, Bi [1 ]
Yu, Haiping [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Dept Orthoped, Jiande Branch,Sch Med, Hangzhou 311600, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Orthoped, Affiliated Hosp 2, Sch Med, Hangzhou 311000, Zhejiang, Peoples R China
关键词
21;
D O I
10.1155/2022/3012589
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To discuss the values of two bone axial X-ray image-based minimally invasive approach surgeries in the diagnosis and treatment of fracture of the calcaneus, 80 patients diagnosed with fracture of the calcaneus by bone axial X-ray examination were selected and divided equally into the minimally invasive longitudinal approach (MILA) group (40 cases) and the sinus tarsal approach (STA) group (40 cases). Besides, the duration of operation, the incidence of complications, the time-to-start weight training, and the American Orthopaedic Foot and Ankle Society (AOFAS) foot function scoring system between the patients in the two groups were compared. The results showed that the duration of operation and incidence of complications among the patients in the MILA group (42.87 +/- 5.12 minutes, 20%) were both superior to those among the patients in the STA group (60.43 +/- 7.31 minutes, 32.5%). The time-to-start weight training in the MILA group was 5.2 weeks, which was obviously shorter than that in the STA group (5.7 weeks). The difference in AOFAS scores between the two groups was not significant. The walking pavement score in the MILA group (4.2 +/- 0.37 points) was slightly higher than that in the STA group (3.3 +/- 0.45 points), and the differences demonstrated statistical meaning (P < 0.05). To sum up, the bone axial X-ray image is an essential examination method of diagnosing fracture of the calcaneus. The two minimally invasive methods both showed good clinical therapeutic effects. The operation of MILA was relatively shorter with fewer complications and is worthy of being promoted as an effective treatment method of fracture of the calcaneus.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Image-Based Estimation and Nonparametric Modeling: Towards Enhanced Geometric Calibration of an X-ray System
    Gaasbeek, Rolf
    van der Maas, Rick
    den Hartog, Mark
    de Jager, Bram
    2015 IEEE CONFERENCE ON CONTROL AND APPLICATIONS (CCA 2015), 2015, : 1063 - 1068
  • [32] Control concepts for image-based structure tracking with ultrafast electron beam X-ray tomography
    Windisch, Dominic
    Bieberle, Martina
    Bieberle, Andre
    Hampel, Uwe
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (04) : 691 - 703
  • [33] Evaluation of Orthodontic Treatment Based on the Registration of X-ray Image Features
    Ge, Yuyan
    Du, Shaoyi
    Cui, Wenting
    Yao, Runzhao
    Zhao, Jiamin
    Han, Mengqi
    Guo, Yucheng
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 4383 - 4387
  • [34] X-Ray Bone Fracture Classification Using Deep Learning: A Baseline for Designing a Reliable Approach
    Tanzi, Leonardo
    Vezzetti, Enrico
    Moreno, Rodrigo
    Moos, Sandro
    APPLIED SCIENCES-BASEL, 2020, 10 (04):
  • [35] Treatment of the distal fracture in radioulna based on the volar wrist dual channel approach and postoperative X-ray diagnosis
    Zheng Li
    Zhenwei Zhang
    Shaoxiao Yu
    Yinwei Bai
    Huixin Lin
    Jinhao Zeng
    Xuelang Ye
    Dachuan Xu
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 695 - 707
  • [36] Treatment of the distal fracture in radioulna based on the volar wrist dual channel approach and postoperative X-ray diagnosis
    Li, Zheng
    Zhang, Zhenwei
    Yu, Shaoxiao
    Bai, Yinwei
    Lin, Huixin
    Zeng, Jinhao
    Ye, Xuelang
    Xu, Dachuan
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 695 - 707
  • [37] Enteryx solution, a minimally invasive injectable treatment for GERD: Analysis of x-ray findings over 12 months
    Johnson, D
    Aisenberg, J
    Cohen, L
    Deviere, J
    Foley, R
    Ganz, R
    Haber, G
    Lehman, G
    Peters, J
    GASTROINTESTINAL ENDOSCOPY, 2003, 57 (05) : AB128 - AB128
  • [38] Automatic Annotation Approach for Prohibited Item in X-ray Image based on PANet
    Ma, Bowen
    Jia, Tong
    Wu, Songsheng
    2020 10TH INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (IEEE-CYBER 2020), 2020, : 130 - 133
  • [39] MR Image Based Approach for Metal Artifact Reduction in X-Ray CT
    Anderla, Andras
    Culibrk, Dubravko
    Delso, Gaspar
    Mirkovic, Milan
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [40] Deformation Behavior Estimation of Aluminum Foam by X-ray CT Image-based Finite Element Analysis
    Hangai, Yoshihiko
    Yamaguchi, Ryo
    Takahashi, Shunya
    Utsunomiya, Takao
    Kuwazuru, Osamu
    Yoshikawa, Nobuhiro
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2013, 44A (04): : 1880 - 1886