Evaluation of the eazyplex MRSA assay for the rapid detection of Staphylococcus aureus in pleural and synovial fluid

被引:10
|
作者
Henares, D. [1 ]
Brotons, P. [1 ,2 ]
Buyse, X. [1 ]
Latorre, I. [1 ,3 ,4 ]
de Paz, H. D. [1 ]
Munoz-Almagro, C. [1 ,2 ,5 ]
机构
[1] Hosp St Joan de Deu, Dept Microbiol Mol, Inst Recerca Pediat, Barcelona, Spain
[2] CIBER Epidemiol & Salud Publ CIBERESP, Barcelona, Spain
[3] Inst Invest Germans Trias & Pujol, Badalona, Spain
[4] CIBER Enfermedades Resp CIBERES, Barcelona, Spain
[5] Univ Int Catalunya, Sch Med, Barcelona, Spain
关键词
MSSA; MRSA; Pleural and synovial fluid; eazyplex MRSA; Performance evaluation; MEDIATED ISOTHERMAL AMPLIFICATION; METHICILLIN-RESISTANT; GENE;
D O I
10.1016/j.ijid.2017.04.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: Loop-mediated isothermal amplification (LAMP) is a simple and sensitive technique for rapid microbiological diagnosis. The aim of this study was to evaluate the analytical and diagnostic performance of the LAMP eazyplex MRSA test for the direct detection and differentiation of methicillin-susceptible (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA) in synovial/pleural fluid. Methods: Analytical validation included the determination of the limit of detection (LoD) and analytical specificity of the eazyplex MRSA test. A diagnostic evaluation of the eazyplex test against bacterial culture was performed on routine pleural/synovial samples collected prospectively from patients aged less than 18 years with complicated pneumonia with empyema or arthritis admitted to the Children's Hospital Sant Joan de Deu in Barcelona, Spain, between April 2015 and May 2016. Results: The new system appropriately detected a quality control panel of clinical samples with DNA of MSSA, MRSA, and other pathogens. The LoD was established at 6.4 x 10(3) CFU/ml for S. aureus and 1.0 x 10(4) CFU/ml for MRSA. Diagnostic validation of the eazyplex MRSA assay was performed on 51 prospective clinical invasive samples, resulting in sensitivity and specificity values of 83.3% and 97.8%, respectively, for S. aureus detection. The mean turnaround time was 70 min. Conclusions: The eazyplex MRSA assay was found to be a useful test for the rapid detection of S. aureus in invasive samples such as pleural/synovial fluid. (C) 2017 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [31] Evaluation of a novel optical assay for rapid detection of methicillin-resistant Staphylococcus aureus in liquid culture
    Knaack, Dennis
    Idelevich, Evgeny A.
    Koerber-Ingang, Barbara
    Kresken, Michael
    Becker, Karsten
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 146 : 68 - 70
  • [32] Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus
    OH, Ae-Chin
    Lee, Jin Kyung
    Lee, Ha Na
    Hong, Young Jun
    Chang, Yoon Hwan
    Hong, Seok-Il
    Kim, Dong Ho
    MOLECULAR MEDICINE REPORTS, 2013, 7 (01) : 11 - 15
  • [33] Controlled evaluation of the IDI-MRSA assay for detection of colonization by methicillin-resistant Staphylococcus aureus in diverse mucocutaneous specimens
    de San, Nour
    Denis, Olivier
    Gasasira, Marie-Fabrice
    De Mendonca, Ricardo
    Nonhoff, Claire
    Struelens, Marc J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (04) : 1098 - 1101
  • [34] RAPID DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS BY CRYSTAL MRSA ID SYSTEM
    QADRI, SMH
    UENO, Y
    IMAMBACCUS, H
    ALMODOVAR, E
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (07) : 1830 - 1832
  • [35] Rapid detection of methicillin resistance in Staphylococcus aureus with the Servitex Staphylocoque MRSA® latex test.
    Scanvic-Hameg, A
    May-Michelangeli, L
    Le Turdu, F
    MEDECINE ET MALADIES INFECTIEUSES, 2002, 32 (02): : 107 - 114
  • [36] Development of fluorescence-linked immunosorbent assay for rapid detection of Staphylococcus aureus
    Kim, Joo-Kyung
    Yun, Hyun-Young
    Kim, Jae-Seok
    Kim, Wooseong
    Lee, Chang-Soo
    Kim, Byung-Gee
    Jeong, Hee-Jin
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2024, 108 (01) : 1 - 10
  • [37] Loop-Mediated Isothermal Amplification Assay for the Rapid Detection of Staphylococcus aureus
    Lim, King Ting
    Teh, Cindy Shuan Ju
    Thong, Kwai Lin
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [38] Comparative Evaluation of Eight Methods for the Detection of Methicillin-Resistant Staphylococcus aureus (MRSA)
    Al-Talib, H.
    Chan, Y. Y.
    Al-Khateeb, A.
    Habsah, H.
    Al-Jashamy, K.
    Ravichandran, M.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2008, 12 : E469 - E469
  • [39] Evaluation of the LightCycler Methicillin-Resistant Staphylococcus aureus (MRSA) Advanced Test for Detection of MRSA Nasal Colonization
    Yam, W. C.
    Siu, Gilman K. H.
    Ho, P. L.
    Ng, T. K.
    Que, T. L.
    Yip, K. T.
    Fok, Cathie P. K.
    Chen, Jonathan H. K.
    Cheng, Vincent C. C.
    Yuen, K. Y.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (09) : 2869 - 2874
  • [40] Development of fluorescence-linked immunosorbent assay for rapid detection of Staphylococcus aureus
    Joo-Kyung Kim
    Hyun-Young Yun
    Jae-Seok Kim
    Wooseong Kim
    Chang-Soo Lee
    Byung-Gee Kim
    Hee-Jin Jeong
    Applied Microbiology and Biotechnology, 2024, 108