Evaluation of the eazyplex MRSA assay for the rapid detection of Staphylococcus aureus in pleural and synovial fluid

被引:10
|
作者
Henares, D. [1 ]
Brotons, P. [1 ,2 ]
Buyse, X. [1 ]
Latorre, I. [1 ,3 ,4 ]
de Paz, H. D. [1 ]
Munoz-Almagro, C. [1 ,2 ,5 ]
机构
[1] Hosp St Joan de Deu, Dept Microbiol Mol, Inst Recerca Pediat, Barcelona, Spain
[2] CIBER Epidemiol & Salud Publ CIBERESP, Barcelona, Spain
[3] Inst Invest Germans Trias & Pujol, Badalona, Spain
[4] CIBER Enfermedades Resp CIBERES, Barcelona, Spain
[5] Univ Int Catalunya, Sch Med, Barcelona, Spain
关键词
MSSA; MRSA; Pleural and synovial fluid; eazyplex MRSA; Performance evaluation; MEDIATED ISOTHERMAL AMPLIFICATION; METHICILLIN-RESISTANT; GENE;
D O I
10.1016/j.ijid.2017.04.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: Loop-mediated isothermal amplification (LAMP) is a simple and sensitive technique for rapid microbiological diagnosis. The aim of this study was to evaluate the analytical and diagnostic performance of the LAMP eazyplex MRSA test for the direct detection and differentiation of methicillin-susceptible (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA) in synovial/pleural fluid. Methods: Analytical validation included the determination of the limit of detection (LoD) and analytical specificity of the eazyplex MRSA test. A diagnostic evaluation of the eazyplex test against bacterial culture was performed on routine pleural/synovial samples collected prospectively from patients aged less than 18 years with complicated pneumonia with empyema or arthritis admitted to the Children's Hospital Sant Joan de Deu in Barcelona, Spain, between April 2015 and May 2016. Results: The new system appropriately detected a quality control panel of clinical samples with DNA of MSSA, MRSA, and other pathogens. The LoD was established at 6.4 x 10(3) CFU/ml for S. aureus and 1.0 x 10(4) CFU/ml for MRSA. Diagnostic validation of the eazyplex MRSA assay was performed on 51 prospective clinical invasive samples, resulting in sensitivity and specificity values of 83.3% and 97.8%, respectively, for S. aureus detection. The mean turnaround time was 70 min. Conclusions: The eazyplex MRSA assay was found to be a useful test for the rapid detection of S. aureus in invasive samples such as pleural/synovial fluid. (C) 2017 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [11] Comparative evaluation of loop mediated isothermal amplification assay for rapid detection of Staphylococcus aureus
    Thakur, Rashmi
    Singh, Randhir
    Kaur, Simranpreet
    Gill, J. P. S.
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2018, 88 (09): : 1003 - 1009
  • [12] EVALUATION OF A NEW COMMERCIAL PCR ASSAY, GENOMERA™ MRSA CONFIRM, FOR RAPID DETECTION OF METHICILIN-RESISTANT STAPHYLOCOCCUS AUREUS FROM OVERNIGHT CULTURE
    Hirvonen, J. J.
    Tissari, P.
    Kaukoranta, S-S.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S605 - S605
  • [13] Rapid and reliable detection of multiresistant Staphylococcus aureus (MRSA) using a multiplex PCR
    Domann, E
    Hossain, H
    Füssle, R
    Chakraborty, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 125 (20) : 613 - 618
  • [14] Rapid Aggregation of Staphylococcus aureus in Synovial Fluid Is Influenced by Synovial Fluid Concentration, Viscosity, and Fluid Dynamics, with Evidence of Polymer Bridging
    Staats, Amelia
    Burback, Peter W.
    Schwieters, Andrew
    Li, Daniel
    Sullivan, Anne
    Horswill, Alexander R.
    Stoodley, Paul
    MBIO, 2022, 13 (02):
  • [15] Multicenter Evaluation of the Xpert MRSA NxG Assay for Detection of Methicillin-Resistant Staphylococcus aureus in Nasal Swabs
    Yarbrough, Melanie L.
    Warren, David K.
    Allen, Karen
    Burkholder, Dennis
    Daum, Robert
    Donskey, Curtis
    Knaack, Dennis
    LaMarca, Anthony
    May, Larissa
    Miller, Loren G.
    Parenti, David M.
    Peterson, Lance
    Thean Yen Tan
    Widen, Raymond
    Hernandez, Diana R.
    Wolk, Donna M.
    Burnham, Carey-Ann D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (01)
  • [16] Evaluation of the Xpert methicillin-resistant Staphylococcus aureus (MRSA) assay using the GeneXpert real-time PCR platform for rapid detection of MRSA from screening specimens
    Rossney, Angela S.
    Herra, Celine M.
    Brennan, Grainne I.
    Morgan, Pamela M.
    O'Connell, Brian
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (10) : 3285 - 3290
  • [17] Evaluation of the IDI-MRSA assay for detection of methicillin-resistant Staphylococcus aureus from clinical specimens
    Lucke, K.
    Hombach, M.
    Pfyffer, G. E.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S235 - S235
  • [18] Evaluation of a Real-Time PCR Assay for Simultaneous Detection of Kingella kingae and Staphylococcus aureus from Synovial Fluid in Suspected Septic Arthritis
    Haldar, Malay
    Butler, Meghan
    Quinn, Criziel D.
    Stratton, Charles W.
    Tang, Yi-Wei
    Burnham, Carey-Ann D.
    ANNALS OF LABORATORY MEDICINE, 2014, 34 (04) : 313 - 316
  • [19] Multicenter Evaluation of the Cepheid Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Test as a Rapid Screening Method for Detection of MRSA in Nares
    Wolk, D. M.
    Picton, E.
    Johnson, D.
    Davis, T.
    Pancholi, P.
    Ginocchio, C. C.
    Finegold, S.
    Welch, D. F.
    de Boer, M.
    Fuller, D.
    Solomon, M. C.
    Rogers, B.
    Mehta, M. S.
    Peterson, L. R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (03) : 758 - 764
  • [20] Rapid detection of Methicillin-Resistant Staphylococcus aureus (MRSA) in nose, groin, and axilla swabs by the BD GeneOhm MRSA achromopeptidase assay and comparison with culture
    Al Zobydi, Abdu
    Jayapal, Venugopal
    Alkhanjaf, Addulrab A.
    Al-Dashel, Yahia A. Yahia
    Divakaran, Mathai P.
    SAUDI MEDICAL JOURNAL, 2013, 34 (06) : 597 - 603