3D Volumetric Tensor Velocity Imaging with Low Computational Complexity Using a Row-Column Addressed Array

被引:0
|
作者
Chetverikova, Kseniya [1 ]
Jensen, Jorgen Arendt [1 ]
Traberg, Marie Sand [1 ]
Stuart, Matthias Bo [1 ]
机构
[1] Denmark Tech Univ, Ctr Fast Ultrasound Imaging, Dept Hlth Technol, DK-2800 Lyngby, Denmark
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 12期
关键词
vector flow imaging; row-columns addressed array; volumetric tensor velocity imaging; ULTRASOUND; SIMULATIONS; DESIGN;
D O I
10.3390/app11125757
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A method for volumetric Tensor Velocity Imaging employing row-column (RC) addressed array with low computational complexity is investigated in simulations. An interleaved and non-interleaved sliding aperture sequence with 11 rows and 11 columns emissions by a 62 + 62 RC addressed array was used. The 3D velocities were estimated by a transverse oscillation (TO) cross-correlation estimator. Parabolic profiles at six different orientations corresponding to combinations of 0, 45 degrees azimuth angles and 90, 75, 60 beam-to-flow angles were investigated with 5 kHz pulse repetition frequencies. The Field II simulations were performed at a depth of 30 mm with peak velocity of 0.3 m/s. Across all vessel orientations, the relative mean bias varied from 2.3% to -14.26%, and the relative standard deviation varied from 0.43% to 5.5%. The best and worst performance was found at beam to flow angles of 90 degrees with 0 degrees rotation angle and 60 degrees beam-to-flow angle with 45 degrees rotation angle respectively. Due to the low channel count of the RC array and the low computational complexity, real-time implementation is feasible on conventional ultrasound systems.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Modeling of 3D gamma interaction position in a monolithic scintillator block with a row-column summing readout
    Bonifacio, Daniel A. B.
    Moralles, Mauricio
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2606 - 2613
  • [42] Three-dimensional ultrafast ultrasound imaging of blood flow using row-column addressing array: A simulation study
    Fu, Ya-Peng
    Sun, Qian-Dong
    Li, Bo-Yi
    Ta, De-An
    Xu, Kai-Liang
    ACTA PHYSICA SINICA, 2023, 72 (07)
  • [43] Encryption and volumetric 3D object reconstruction using multispectral computational integral imaging
    Muniraj, Inbarasan
    Kim, Byoungho
    Lee, Byung-Guen
    APPLIED OPTICS, 2014, 53 (27) : G25 - G32
  • [44] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (06) : 978 - 988
  • [45] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Phantom Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) : 1182 - 1192
  • [46] Fourier-Based Fast 3-D Ultrasound Imaging Using Row-Column-Addressed 2-D Arrays
    Lin, Shang-Ching
    Li, Pai-Chi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 85 - 101
  • [47] Monitoring microvascular changes over time with a repositionable 3D ultrasonic capacitive micromachined row-column sensor
    Blanquart, Cyprien
    Davenet, Lea
    Claisse, Julien
    Giroud, Mallorie
    Boulme, Audren
    Jeanne, Edgard
    Tanter, Mickael
    Correia, Mafalda
    Deffieux, Thomas
    SCIENCE ADVANCES, 2025, 11 (13):
  • [48] An image encryption algorithm based on a 3D chaotic Hopfield neural network and random row-column permutation
    Yao, Wei
    Gao, Kai
    Zhang, Zhihao
    Cui, Li
    Zhang, Jin
    FRONTIERS IN PHYSICS, 2023, 11
  • [49] Low Complexity 3D Ultrasound Imaging Using Synthetic Aperture Sequential Beamforming
    Zhou, Jian
    Wei, Siyuan
    Sampson, Richard
    Yang, Ming
    Jintamethasawat, Rungroj
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    2016 IEEE INTERNATIONAL WORKSHOP ON SIGNAL PROCESSING SYSTEMS (SIPS), 2016, : 33 - 38
  • [50] Row-Column-Based Coherence Imaging Using a 2-D Array Transducer: A Row-Based Implementation
    Fatemi, Ali
    Masoy, Svein-Erik
    Rodriguez-Molares, Alfonso
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) : 2303 - 2311