Fourier-Based Fast 3-D Ultrasound Imaging Using Row-Column-Addressed 2-D Arrays

被引:0
|
作者
Lin, Shang-Ching [1 ]
Li, Pai-Chi [1 ,2 ]
机构
[1] Natl Taiwan Univ, Grad Inst Biomed Elect & Bioinformat, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Dept Elect Engn, Taipei 10617, Taiwan
关键词
Angular compounding; Fourier-based imaging; row-column-addressed (RCA) array; ultrasound 3-D imaging; TRANSDUCER; DESIGN; MATRIX;
D O I
10.1109/TUFFC.2023.3340507
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A Fourier-based fast 3-D ultrasound imaging method using row-column-addressed (RCA) 2-D arrays is presented. The row elements in an RCA array are activated sequentially, and all the column elements are used to receive. The obtained dataset is adapted to approximate to that obtained using a fully sampled array after a plane wave at a given incident angle is transmitted. In this way, the fast algorithm in plane-wave Fourier imaging (PWFI) can be applied to the adapted dataset. In addition, synthesizing multiple datasets based on multiple incident angles enables angular compounding, which improves the image quality. The proposed method was validated using computer simulations and physical-phantom experiments. The results show that the spatial resolution and contrast of the proposed method are comparable with those of its PWFI counterpart without requiring a fully sampled (FS) array. Compared with the delay-and sum (DAS) method using the RCA array, the proposed method provides comparable spatial resolution but lower contrast; however, the computational complexity is significantly reduced from O((NNz)-N-4) to O(WN(2)N(z)log(2)((NNz)-N-2)), where N is the number of elements on each side of the RCA array, N-z is the number of voxels in the axial direction in the output image, and W is the number of compounding angles. For example, in the simulated results when the maximum compounding angle M is 5(degrees), at a given point the lateral - 6-dB width provided by the proposed method is 0.241 mm (0.267 mm for DAS), the contrast ratio of a hyperechoic cyst is 8.87 dB (9.10 dB for DAS), the number of real number operations is reduced by a factor of 20.62, and the number of memory accesses is reduced by a factor of 47.21, both compared with DAS. This novel fast algorithm could facilitate the development of compact real-time 3-D imaging systems, especially when the channel count is high and a large field of view (FOV) is required.
引用
收藏
页码:85 / 101
页数:17
相关论文
共 50 条
  • [1] 3-D Imaging using Row-Column-Addressed 2-D Arrays with a Diverging Lens
    Bouzari, Hamed
    Engholm, Mathias
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [2] Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [3] 3-D Imaging using Row-Column-Addressed 2-D Arrays with a Diverging Lens: Phantom Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (06) : 978 - 988
  • [5] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Phantom Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) : 1182 - 1192
  • [6] 3-D Vector Flow Estimation With Row-Column-Addressed Arrays
    Holbek, Simon
    Christiansen, Thomas Lehrmann
    Stuart, Matthias Bo
    Beers, Christopher
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (11) : 1799 - 1814
  • [7] Probe development of CMUT and PZT row-column-addressed 2-D arrays
    Engholm, Mathias
    Bouzari, Hamed
    Christiansen, Thomas Lehrmann
    Beers, Christopher
    Bagge, Jan Peter
    Moesner, Lars Nordahl
    Diederichsen, Soren Elmin
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2018, 273 : 121 - 133
  • [8] Capacitive Substrate Coupling of Row-Column-Addressed 2-D CMUT Arrays
    Engholm, Mathias
    Bouzari, Hamed
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [9] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [10] 3-D Imaging Using Row-Column-Addressed Arrays With Integrated Apodization-Part II: Transducer Fabrication and Experimental Results
    Christiansen, Thomas Lehrmann
    Rasmussen, Morten Fischer
    Bagge, Jan Peter
    Moesner, Lars Nordahl
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) : 959 - 971