Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip

被引:248
|
作者
Baumgaertner, MR
Solberg, BD
机构
[1] Yale University, New Haven
[2] Deparment of Orthopaedics and Rehab., Yale Physicians Building, Yale University School of Medicine, New Haven, CT 06510
来源
关键词
D O I
10.1302/0301-620X.79B6.7949
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and lateral views, This decreased from a mean of 25 mm in the control group to 20 mm in the study group (p = 0.0001). The number of mechanical failures by cut-out of the screw from the head decreased from 16 (8%) in the control group at a mean of 13 months to none in the study group at a mean of eight months (p=0.0015). There were significantly fewer poor reductions in the study group. Our study confirms the importance of good surgical technique in the treatment of trochanteric fractures and supports the concept of the TAD as a clinically useful way of describing the position of the screw.
引用
收藏
页码:969 / 971
页数:3
相关论文
共 50 条
  • [41] Accuracy of the surgeon's eye: Use of the tip-apex distance in clinical practice
    Wright, Jonathan
    Kahane, Steven
    Moeed, Abdul
    MacDowell, Andrew
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (07): : 1346 - 1348
  • [42] Measuring tip-apex distance using a picture archiving and communication system (PACS)
    Johnson, Luke J.
    Cope, Marcus R.
    Shahrokhi, Shahram
    Tarnblyn, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (07): : 786 - 790
  • [43] Trochanteric hip fractures - Fixation failure commoner with femoral medialization, a comparison of 101 cases
    Parker, MJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (04): : 329 - 332
  • [44] Tip-apex distance as a risk factor for cut-out in cephalic double-screw nailing of intertrochanteric femur fractures
    Coviello, M.
    Abate, A.
    Maccagnano, G.
    Ippolito, F.
    Nappi, V.
    Abbaticchio, A. M.
    Caiaffa, E.
    Caiaffa, V.
    BONE & JOINT OPEN, 2024, 5 (06): : 457 - 463
  • [45] Risk Factors Associated with Failure of Cephalomedullary Nail Fixation in the Treatment of Trochanteric Hip Fractures
    Yoo, Jehyun
    Chang, Jundong
    Park, Changwon
    Hwang, Jihyo
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (01) : 29 - 36
  • [46] Outcomes of trochanteric external fixation for geriatric inter-trochanteric hip fractures
    Yousry, Ahmed H.
    Chotai, Pranit N.
    El Ghazaly, Sherif A.
    Fayyad, Tamer A.
    Abdelgawad, Amr A.
    JOURNAL OF ORTHOPAEDICS, 2015, 12 (04) : 174 - 178
  • [47] Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation
    Yang, Yun-fa
    Huang, Jian-wen
    Gao, Xiao-sheng
    Xu, Zhong-he
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [48] Does Tip Apex Distance Predict Implant Failure in Stable Intertrochanteric Fractures of Femur?
    Noor, Fraz
    Nasir, Hafiz Muhammad
    Ahmad, Shahbaz
    Kumar, Jugdesh
    Mahar, Sijad Ahmed
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (03): : 576 - 578
  • [49] What Is the Relevance of the Tip-Apex Distance as a Predictor of Lag Screw Cut-Out?
    Goffin, Jerome M.
    Jenkins, Paul J.
    Ramaesh, Rishikesan
    Pankaj, Pankaj
    Simpson, A. Hamish
    PLOS ONE, 2013, 8 (08):
  • [50] Treatment of intertrochanteric hip fractures with the AO trochanteric fixation nail
    Gardner, MJ
    Bhandari, M
    Lawrence, BD
    Helfet, DL
    Lorich, DG
    ORTHOPEDICS, 2005, 28 (02) : 117 - 122