Seismic Isolation: An Effective Technique for the Seismic Retrofitting of a Reinforced Concrete Building

被引:3
|
作者
Giarlelis, Christos [1 ]
Koufalis, Dimitrios [1 ]
Repapis, Constantinos [2 ]
机构
[1] Equidas Consulting Engineers, Athens, Greece
[2] Univ West Attica, Dept Civil Engn, Egaleo, Greece
关键词
seismic isolation; structural assessment; seismic retrofitting; non-linear dynamic analysis; friction-pendulum system; RANDOM VIBRATION; SYSTEM;
D O I
10.1080/10168664.2019.1678449
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation, usually applied for new structures, is used for the seismic upgrade of a five-storey reinforced concrete building. The building is a frame structure, representative of the residential buildings designed in the 1960s and 1970s in Greece and southern Europe, and thus following an older generation of codes. Response spectrum analysis, performed for the seismic assessment of the structure, using EC8 code provisions, showed poor structural performance and inadequate capacity of many structural members. A seismic upgrade of the structure is thus needed and the use of friction-pendulum system bearings, placed above the foundation level, is examined. A series of linear and non-linear analyses is performed and the results show a major improvement in the overall seismic performance of the building, while interventions are required only at the ground floor and foundation levels. The effectiveness and limitations in the applicability of this retrofitting procedure are discussed. It is concluded that the seismic retrofitting of existing buildings through the use of seismic isolation is an effective approach. It results in an enhanced performance level compared to conventional approaches; therefore, it should always be considered as an alternative to conventional retrofitting techniques.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [41] Seismic evaluation and retrofit of a typical reinforced concrete hospital building in Indonesia with DCFP isolation system
    Imran, Iswandi
    Siringoringo, Dionysius M.
    Rainayana, Salma S.
    STRUCTURES, 2024, 64
  • [42] Seismic Isolation Layout Optimized of Mid-Rise Reinforced Concrete Building Frame Structure
    Liu, Shengkun
    Chen, Zhidong
    Liu, Yongdou
    BUILDINGS, 2024, 14 (07)
  • [43] Optimum seismic retrofitting technique for buildings
    Azmoodeh, B. M.
    Moghadam, A. S.
    CIVIL ENGINEERING AND ENVIRONMENTAL SYSTEMS, 2011, 28 (01) : 61 - 74
  • [44] Seismic evaluation of existing reinforced cement concrete building and steel–concrete composite building
    Patil S.K.
    Pujari A.B.
    Undre A.R.
    Jadhav V.V.
    Asian Journal of Civil Engineering, 2024, 25 (5) : 4133 - 4140
  • [45] Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment
    Ferraioli, Massimiliano
    Mandara, Alberto
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [46] Seismic retrofitting of a historic building by using an isolation system with a weak restoring force
    Zhang, Ruifu
    Wu, Minjun
    Lu, Wensheng
    Li, Xuan
    Lu, Xilin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 148 (148)
  • [47] Concrete or FRP jacketing of concrete columns for seismic retrofitting
    Bousias, Stathis N.
    Fardis, Michael N.
    Spathis, Alex-Loukas
    Biskinis, Dionysis
    ADVANCES IN EARTHQUAKE ENGINEERING FOR URBAN RISK REDUCTION, 2006, 66 : 33 - +
  • [48] Seismic Retrofitting of Masonry with Fabric Reinforced Mortar
    De Santis, S.
    De Canio, G.
    de Felice, G.
    Roselli, I
    PROCEEDINGS OF ITALIAN CONCRETE DAYS 2018, 2020, 42 : 337 - 346
  • [49] Effectiveness of seismic isolation in a reinforced concrete structure with soft story
    Ozturk, Hakan
    Cavdar, Esengul
    Ozdemir, Gokhan
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 87 (05) : 405 - 418
  • [50] Wave dynamic analysis of the seismic response of a reinforced concrete building
    Astroza, Rochigo
    Saragoni, G. Rodolfo
    2008 SEISMIC ENGINEERING CONFERENCE COMMEMORATING THE 1908 MESSINA AND REGGIO CALABRIA EARTHQUAKE, PTS 1 AND 2, 2008, 1020 : 1795 - +