Seismic Isolation: An Effective Technique for the Seismic Retrofitting of a Reinforced Concrete Building

被引:3
|
作者
Giarlelis, Christos [1 ]
Koufalis, Dimitrios [1 ]
Repapis, Constantinos [2 ]
机构
[1] Equidas Consulting Engineers, Athens, Greece
[2] Univ West Attica, Dept Civil Engn, Egaleo, Greece
关键词
seismic isolation; structural assessment; seismic retrofitting; non-linear dynamic analysis; friction-pendulum system; RANDOM VIBRATION; SYSTEM;
D O I
10.1080/10168664.2019.1678449
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation, usually applied for new structures, is used for the seismic upgrade of a five-storey reinforced concrete building. The building is a frame structure, representative of the residential buildings designed in the 1960s and 1970s in Greece and southern Europe, and thus following an older generation of codes. Response spectrum analysis, performed for the seismic assessment of the structure, using EC8 code provisions, showed poor structural performance and inadequate capacity of many structural members. A seismic upgrade of the structure is thus needed and the use of friction-pendulum system bearings, placed above the foundation level, is examined. A series of linear and non-linear analyses is performed and the results show a major improvement in the overall seismic performance of the building, while interventions are required only at the ground floor and foundation levels. The effectiveness and limitations in the applicability of this retrofitting procedure are discussed. It is concluded that the seismic retrofitting of existing buildings through the use of seismic isolation is an effective approach. It results in an enhanced performance level compared to conventional approaches; therefore, it should always be considered as an alternative to conventional retrofitting techniques.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [21] Influence of seismic isolation on the seismic design of buildings with reinforced concrete wall structure
    Nino-Castano, Jorge A.
    Chalarca, Bryan
    Bedoya-Ruiz, Daniel
    INGENIERIA Y COMPETITIVIDAD, 2024, 26 (01):
  • [22] SEISMIC ISOLATION RETROFITTING OF THE SALT-LAKE-CITY AND COUNTY BUILDING
    BAILEY, J
    ALLEN, E
    NUCLEAR ENGINEERING AND DESIGN, 1991, 127 (03) : 367 - 374
  • [23] Seismic Retrofitting: Reinforced concrete shear wall versus CFRP reinforced concrete using pushover analysis
    Riyad, Y.
    Kissi, B.
    Mrani, I.
    Parron, M. A.
    Dolores, R. C. M.
    JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES, 2016, 3 (04): : 181 - 195
  • [24] Efficiency of Seismic Isolation for Seismic Retrofitting of Heavy Substructured Bridges
    Dicleli, Murat
    Mansour, Mohamad Y.
    Constantinou, Michael C.
    JOURNAL OF BRIDGE ENGINEERING, 2005, 10 (04) : 429 - 441
  • [25] Seismic Performance of Reinforced Concrete Building with Flat Slab
    Kayastha, Nipan Bhandar
    Debbarma, Rama
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS AND STRUCTURES FOR CIVIL INFRASTRUCTURES (SMSCI2019), 2019, 2158
  • [26] Seismic fragility curves for old reinforced concrete building
    Patil, V.S.
    Tande, S.N.
    Journal of Structural Engineering (India), 2018, 45 (03): : 264 - 274
  • [27] Seismic performance of a reinforced concrete frame building in China
    Duan, Haijuan
    Hueste, Mary Beth D.
    ENGINEERING STRUCTURES, 2012, 41 : 77 - 89
  • [28] Life-Cycle Assessment of Contemporary and Classical Seismic Retrofitting Approaches Applied to a Reinforced Concrete Building in Israel
    Pushkar, Svetlana
    Halperin, Ido
    Ribakov, Yuri
    BUILDINGS, 2022, 12 (11)
  • [29] Seismic retrofitting of a deteriorated RC building
    Selim, Mohamed
    Ibrahim, Yasser E.
    Emara, Mohamed
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 18
  • [30] Base Isolation for Seismic Retrofitting of Structures
    Matsagar, Vasant A.
    Jangid, R. S.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2008, 13 (04) : 175 - 185