Seismic Isolation: An Effective Technique for the Seismic Retrofitting of a Reinforced Concrete Building

被引:3
|
作者
Giarlelis, Christos [1 ]
Koufalis, Dimitrios [1 ]
Repapis, Constantinos [2 ]
机构
[1] Equidas Consulting Engineers, Athens, Greece
[2] Univ West Attica, Dept Civil Engn, Egaleo, Greece
关键词
seismic isolation; structural assessment; seismic retrofitting; non-linear dynamic analysis; friction-pendulum system; RANDOM VIBRATION; SYSTEM;
D O I
10.1080/10168664.2019.1678449
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation, usually applied for new structures, is used for the seismic upgrade of a five-storey reinforced concrete building. The building is a frame structure, representative of the residential buildings designed in the 1960s and 1970s in Greece and southern Europe, and thus following an older generation of codes. Response spectrum analysis, performed for the seismic assessment of the structure, using EC8 code provisions, showed poor structural performance and inadequate capacity of many structural members. A seismic upgrade of the structure is thus needed and the use of friction-pendulum system bearings, placed above the foundation level, is examined. A series of linear and non-linear analyses is performed and the results show a major improvement in the overall seismic performance of the building, while interventions are required only at the ground floor and foundation levels. The effectiveness and limitations in the applicability of this retrofitting procedure are discussed. It is concluded that the seismic retrofitting of existing buildings through the use of seismic isolation is an effective approach. It results in an enhanced performance level compared to conventional approaches; therefore, it should always be considered as an alternative to conventional retrofitting techniques.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [1] Seismic evaluation and retrofitting of reinforced concrete buildings with base isolation systems
    Vasiliadis, Lazaros K.
    EARTHQUAKES AND STRUCTURES, 2016, 10 (02) : 293 - 311
  • [2] Seismic retrofitting of a building with reinforced concrete structure with the use of dissipative braces
    Opere di miglioramento sismico con l'impiego di controventi dissipativi, di un edificio con struttura in cemento armato
    Giovannardi, E., 2012, Patron Editore S.r.l. (29):
  • [3] Seismic retrofitting of reinforced concrete buildings in Romania
    Crainic, L
    VRANCEA EARTHQUAKES: TECTONICS, HAZARD AND RISK MITIGATION, 1999, : 197 - 205
  • [4] Design of seismic retrofitting of reinforced concrete structures
    Dritsos, S
    Earthquake Resistant Engineering Structures V, 2005, 81 : 557 - 566
  • [5] Seismic Assessment and Retrofitting of Reinforced Concrete Structures
    Bosco, Melina
    Rossi, Pier Paolo
    APPLIED SCIENCES-BASEL, 2022, 12 (14):
  • [6] Seismic retrofitting of reinforced concrete frame-shear wall buildings using seismic isolation for resilient performance
    Wang, Xinyu
    Xie, Linlin
    Zeng, Demin
    Yang, Cantian
    Liu, Qianmin
    STRUCTURES, 2021, 34 : 4745 - 4757
  • [7] Seismic resistance of a reinforced concrete building before and after retrofitting -: Part 1:: The existing building
    Marletta, M
    Caliò, I
    STRUCTURES UNDER SHOCK AND IMPACT VIII, 2004, 15 : 293 - 306
  • [8] Seismic resistance of a reinforced concrete building before and after retrofitting -: Part II:: The retrofitted building
    Marletta, M
    Vaccaro, S
    Caliò, I
    STRUCTURES UNDER SHOCK AND IMPACT VIII, 2004, 15 : 307 - 322
  • [9] Seismic upgrade of a reinforced concrete building
    Bayrak, O
    Binici, B
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES III, 2001, 9 : 465 - 474
  • [10] Ambient and forced vibration testing of a reinforced concrete building before and after its seismic retrofitting
    Soyoz, Serdar
    Taciroglu, Ertugrul
    Orakcal, Kutay
    Nigbor, Robert
    Skolnik, Derek
    Lus, Hilmi
    Safak, Erdal
    Journal of Structural Engineering (United States), 2013, 139 (10): : 1741 - 1752