How Precise Is Computer-navigated Gap Assessment in TKA?

被引:14
|
作者
Stiehl, James B. [1 ]
Heck, David A. [2 ]
机构
[1] St Marys Hosp, Dept Surg, Centralia, IL 62801 USA
[2] Methodist Dallas Med Ctr, Dept Orthopaed Surg, Dallas, TX USA
关键词
TOTAL KNEE ARTHROPLASTY; SOFT-TISSUE BALANCE; REGISTRATION PROCESS; JOINT; ANTERIOR; ERRORS;
D O I
10.1007/s11999-014-3785-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Methods to improve gap balancing in total knee arthroplasty (TKA) include the development of calibrated distractors and various devices to determine the distances of the gaps. However, few studies have validated the accuracy or precision of computer navigation to determine these measurements, especially gaps created after bone cuts have been made; doing so would be important, because optimal surgical technique relies on appropriate gap spacing. We investigated the ability of a new image-free computer navigation surface registration protocol to measure gap distances in TKA. Eight embalmed cadaveric specimens of the lower extremity were used. A surface registration software protocol defined the most distal and posterior surface points of the femoral condyles and the navigation system measured the distance of the most distal femoral condyle point to the surface of the tibia after tibial resection. The tibial resection was perpendicular to the mechanical axis and was cut with a 7A degrees posterior slope. The navigation system measured gaps spaced by modular spacing blocks at 5A degrees intervals from full extension to 120A degrees of flexion. Repeatability assessed repeated measures by one surgeon. Reproducibility was assessed by performing the same measurements after complete reregistration of the computer protocol to the cadaver bones. The gaps measured by the computer were statistically the same as those assessed with the use of blocks with a maximum measurement error of 1 mm. Reregistration did introduce error into the measurement. The gaps changed with position of knee flexion, and there was gradual and significant stretching of the gaps with repeated measurements. Preliminary testing shows that computer navigation can reproduce static measurements reliably and with equal accuracy as spacer blocks. We have not demonstrated that this could be applied in a dynamic setting. This computer navigation system has sufficient precision to warrant investigation in the clinical setting for measuring gaps created during the surgical procedure.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 50 条
  • [21] Comparison of conventional versus computer-navigated acetabular component insertion
    Haaker, Rolf G. A.
    Tiedjen, Kai
    Ottersbach, Andreas
    Rubenthaler, Frank
    Stockheim, Marthin
    Stiehl, James B.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (02): : 151 - 159
  • [22] False malalignment after computer-navigated total knee arthroplasty
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    KNEE, 2021, 30 : 100 - 105
  • [23] Clinical results of computer-navigated anterior cruciate ligament reconstructions
    Valentin, P
    Hofbauer, M
    Aldrian, S
    ORTHOPEDICS, 2005, 28 (10) : S1289 - S1291
  • [24] Tibial stress fracture after computer-navigated total knee arthroplasty
    Massai F.
    Conteduca F.
    Vadalà A.
    Iorio R.
    Basiglini L.
    Ferretti A.
    Journal of Orthopaedics and Traumatology, 2010, 11 (2) : 123 - 127
  • [25] The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty
    R. E. da Assunção
    N. J. Hancock
    W. J. M. Bruce
    P. Walker
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2528 - 2534
  • [26] Gap difference in navigated TKA: a measure of the imbalanced flexion-extension gap
    Chia, Zi-Yang
    Pang, Hee-Nee
    Tan, Mann-Hong
    Yeo, Seng-Jin
    SICOT-J, 2018, 4
  • [27] The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty
    da Assuncao, R. E.
    Hancock, N. J.
    Bruce, W. J. M.
    Walker, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (12) : 2528 - 2534
  • [28] Proven accuracy for a new dynamic gap measurement in navigated TKA
    Volkmar Mehliß
    Marco Strauch Leira
    Agustín Serrano Olaizola
    Wolfgang Scior
    Heiko Graichen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1189 - 1195
  • [29] Proven accuracy for a new dynamic gap measurement in navigated TKA
    Mehliss, Volkmar
    Strauch Leira, Marco
    Serrano Olaizola, Agustin
    Scior, Wolfgang
    Graichen, Heiko
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1189 - 1195
  • [30] Safety and Efficacy of Intraoperative Computer-Navigated Versus Non-Navigated Shoulder Arthroplasty at a Tertiary Referral
    Barrett, Ian
    Ramakrishnan, Anna
    Cheung, Emilie
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2019, 50 (01) : 95 - +