How Precise Is Computer-navigated Gap Assessment in TKA?

被引:14
|
作者
Stiehl, James B. [1 ]
Heck, David A. [2 ]
机构
[1] St Marys Hosp, Dept Surg, Centralia, IL 62801 USA
[2] Methodist Dallas Med Ctr, Dept Orthopaed Surg, Dallas, TX USA
关键词
TOTAL KNEE ARTHROPLASTY; SOFT-TISSUE BALANCE; REGISTRATION PROCESS; JOINT; ANTERIOR; ERRORS;
D O I
10.1007/s11999-014-3785-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Methods to improve gap balancing in total knee arthroplasty (TKA) include the development of calibrated distractors and various devices to determine the distances of the gaps. However, few studies have validated the accuracy or precision of computer navigation to determine these measurements, especially gaps created after bone cuts have been made; doing so would be important, because optimal surgical technique relies on appropriate gap spacing. We investigated the ability of a new image-free computer navigation surface registration protocol to measure gap distances in TKA. Eight embalmed cadaveric specimens of the lower extremity were used. A surface registration software protocol defined the most distal and posterior surface points of the femoral condyles and the navigation system measured the distance of the most distal femoral condyle point to the surface of the tibia after tibial resection. The tibial resection was perpendicular to the mechanical axis and was cut with a 7A degrees posterior slope. The navigation system measured gaps spaced by modular spacing blocks at 5A degrees intervals from full extension to 120A degrees of flexion. Repeatability assessed repeated measures by one surgeon. Reproducibility was assessed by performing the same measurements after complete reregistration of the computer protocol to the cadaver bones. The gaps measured by the computer were statistically the same as those assessed with the use of blocks with a maximum measurement error of 1 mm. Reregistration did introduce error into the measurement. The gaps changed with position of knee flexion, and there was gradual and significant stretching of the gaps with repeated measurements. Preliminary testing shows that computer navigation can reproduce static measurements reliably and with equal accuracy as spacer blocks. We have not demonstrated that this could be applied in a dynamic setting. This computer navigation system has sufficient precision to warrant investigation in the clinical setting for measuring gaps created during the surgical procedure.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 50 条
  • [11] Computer-navigated total knee arthroplasty in haemophilic arthropathy
    Cho, K. -Y.
    Kim, K. -I.
    Khurana, S.
    Cho, S. -W.
    Kang, D. -G.
    HAEMOPHILIA, 2013, 19 (02) : 259 - 266
  • [12] Systematic review of computer-navigated total knee arthroplasty
    Zamora, Luis A.
    Humphreys, Karen J.
    Watt, Amber M.
    Forel, Deanne
    Cameron, Alun L.
    ANZ JOURNAL OF SURGERY, 2013, 83 (1-2) : 22 - 30
  • [13] A Simple and Flexible Concept for Computer-Navigated Surgery of the Mandible
    Luebbers, Heinz-Theo
    Obwegeser, Joachim A.
    Matthews, Felix
    Eyrich, Gerold
    Graetz, Klaus Wilhelm
    Kruse, Astrid
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (03) : 924 - 930
  • [14] Minimally invasive imageless computer-navigated knee surgery
    Chandrasekaran, Sivashankar
    Molnar, Robert B.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 441 - 445
  • [15] Fractures associated with computer-navigated total knee arthroplasty
    Jung, Ho-Joong
    Jung, Young-Bok
    Song, Kwang-Sup
    Park, Se-Jin
    Lee, Jong-Seok
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10): : 2280 - 2284
  • [16] Accuracy of CT based computer-navigated total hip arthroplasty
    Steppacher, S. D.
    Tannast, M.
    Zheng, G.
    Zhang, X.
    Kowal, J.
    Siebenrock, K. A.
    Murphy, S. B.
    SWISS MEDICAL WEEKLY, 2009, 139 (23-24) : 44S - 44S
  • [17] Total Knee Arthroplasty With a Computer-navigated Saw: A Pilot Study
    Garvin, Kevin L.
    Barrera, Andres
    Mahoney, Craig R.
    Hartman, Curtis W.
    Haider, Hani
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (01) : 155 - 161
  • [18] Ultrasound, a new tool for surface matching in computer-navigated surgery
    Liener, UC
    Krivonos, O
    Männer, R
    Hesser, J
    Kinzl, L
    Gebhard, F
    MILITARY MEDICINE, 2002, 167 (02) : 151 - 154
  • [19] Computer-Navigated Contouring of Craniofacial Fibrous Dysplasia Involving the Orbit
    Nowinski, Daniel
    Messo, Elias
    Hedlund, Anders
    Hirsch, Jan-Michael
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (02) : 469 - 472
  • [20] Principles and new concepts in computer-navigated total hip arthroplasty
    Renkawitz, T.
    Woerner, M.
    Sendtner, E.
    Weber, M.
    Lechler, P.
    Grifka, J.
    ORTHOPADE, 2011, 40 (12): : 1095 - +