How Precise Is Computer-navigated Gap Assessment in TKA?

被引:14
|
作者
Stiehl, James B. [1 ]
Heck, David A. [2 ]
机构
[1] St Marys Hosp, Dept Surg, Centralia, IL 62801 USA
[2] Methodist Dallas Med Ctr, Dept Orthopaed Surg, Dallas, TX USA
关键词
TOTAL KNEE ARTHROPLASTY; SOFT-TISSUE BALANCE; REGISTRATION PROCESS; JOINT; ANTERIOR; ERRORS;
D O I
10.1007/s11999-014-3785-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Methods to improve gap balancing in total knee arthroplasty (TKA) include the development of calibrated distractors and various devices to determine the distances of the gaps. However, few studies have validated the accuracy or precision of computer navigation to determine these measurements, especially gaps created after bone cuts have been made; doing so would be important, because optimal surgical technique relies on appropriate gap spacing. We investigated the ability of a new image-free computer navigation surface registration protocol to measure gap distances in TKA. Eight embalmed cadaveric specimens of the lower extremity were used. A surface registration software protocol defined the most distal and posterior surface points of the femoral condyles and the navigation system measured the distance of the most distal femoral condyle point to the surface of the tibia after tibial resection. The tibial resection was perpendicular to the mechanical axis and was cut with a 7A degrees posterior slope. The navigation system measured gaps spaced by modular spacing blocks at 5A degrees intervals from full extension to 120A degrees of flexion. Repeatability assessed repeated measures by one surgeon. Reproducibility was assessed by performing the same measurements after complete reregistration of the computer protocol to the cadaver bones. The gaps measured by the computer were statistically the same as those assessed with the use of blocks with a maximum measurement error of 1 mm. Reregistration did introduce error into the measurement. The gaps changed with position of knee flexion, and there was gradual and significant stretching of the gaps with repeated measurements. Preliminary testing shows that computer navigation can reproduce static measurements reliably and with equal accuracy as spacer blocks. We have not demonstrated that this could be applied in a dynamic setting. This computer navigation system has sufficient precision to warrant investigation in the clinical setting for measuring gaps created during the surgical procedure.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 50 条
  • [1] Conventional versus computer-navigated TKA: a prospective randomized study
    Alessandro Todesca
    Luca Garro
    Massimo Penna
    Jacques Bejui-Hugues
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1778 - 1783
  • [2] Conventional versus computer-navigated TKA: a prospective randomized study
    Todesca, Alessandro
    Garro, Luca
    Penna, Massimo
    Bejui-Hugues, Jacques
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) : 1778 - 1783
  • [3] Computer-navigated TKA for the Treatment of Osteoarthritis Associated With Extra-articular Femoral Deformity
    Shao, Junjie
    Zhang, Wen
    Jiang, Yao
    Wang, Qi
    Chen, Yunsu
    Shen, Hao
    Zhang, Xianlong
    ORTHOPEDICS, 2012, 35 (06) : E794 - E799
  • [4] Positioning tasks in multimodal computer-navigated surgery
    Brell, Melina
    Hein, Andreas
    IEEE MULTIMEDIA, 2007, 14 (04) : 42 - 51
  • [5] Is TKA with computer-assisted navigation associated with less blood loss? A comparative study between computer-navigated and conventional method
    Mitsiou, Diamantis
    Pakos, Emilios E.
    Papadopoulos, Dimitrios, V
    Georgiadis, Giorgos
    Gelalis, Ioannis D.
    Tsantes, Andreas G.
    Gkiatas, Ioannis
    Kalos, Nikos
    Xenakis, Theodoros A.
    JOURNAL OF ORTHOPAEDICS, 2020, 20 : 50 - 53
  • [6] Accuracy of Computer-Navigated Total Hip Arthroplasty
    Snyder, Garrett M.
    Calderon, Santiago A. Lozano
    Lucas, Paul A.
    Russinoll, Scott
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03): : 415 - 420
  • [7] Computer-Navigated Total Knee Arthroplasty Utilization
    Bala, Abiram
    Penrose, Colin Thomas
    Seyler, Thorsten Markus
    Mather, Richard Chad, III
    Wellman, Samuel Secord
    Bolognesi, Michael Paul
    JOURNAL OF KNEE SURGERY, 2016, 29 (05) : 430 - 435
  • [8] Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation
    Decking, R
    Markmann, Y
    Fuchs, J
    Puhl, W
    Scharf, HP
    JOURNAL OF ARTHROPLASTY, 2005, 20 (03): : 282 - 288
  • [9] Minimally Invasive Computer-Navigated Total Knee Arthroplasty
    Biasca, Nicola
    Schneider, Thomas-Oliver
    Bungartz, Matthias
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (04) : 537 - +
  • [10] Computer-Navigated Versus Conventional Total Knee Arthroplasty
    Kim, Young-Hoo
    Park, Jang-Won
    Kim, Jun-Shik
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (22): : 2017 - 2024