Aortic Root Enlargement in Patients With Small Aortic Annulus Undergoing Double Valve Replacement: A Retrospective Comparative Cohort Study

被引:2
|
作者
Mubarak, Yasser Shaban [1 ,2 ]
Jawad, Ahmed Abdel Rahman Abdel [3 ,4 ]
机构
[1] Menia Univ, Dept Cardiothorac Surg, Al Minya, Egypt
[2] King Fahad Cent Hosp, Madinah Cardiac Ctr, Dammam, Saudi Arabia
[3] Cairo Univ, Dept Cardiothorac Surg, Cairo, Egypt
[4] Stadt Klinikum Braunschweig, Clin Cardiothorac & Vasc Surg, Braunschweig, Germany
来源
HEART SURGERY FORUM | 2021年 / 24卷 / 02期
关键词
Aortic Root Enlargement; Small Aortic Annulus; Double Valve Replacement; Patient-Prosthesis Mismatch; Nick's / Manouguian procedure; RISK;
D O I
10.1532/hsf.3401
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Small aortic annulus (AA) is a big issue during aortic valve replacement (AVR), necessitating replacement of an undersized prosthetic valve especially with double valve replacement (DVR). Despite the fact that small aortic valve prostheses can lead to prosthesis-patient mismatch (PPM), there remains reluctance to perform aortic root enlargement (ARE) procedures, fearing morbidity and mortality. Objective: To evaluate clinical and echocardiographic outcomes in patients with small aortic annulus (<18 mm) undergoing double valve replacement. Methods: The study included 100 consecutive patients who underwent DVR for combined rheumatic aortic and mitral valve diseases, between January 2016 and September 2020. Only 50 patients had ARE with DVR. ARE was performed using an autologous or bovine pericardium or Dacron patch by Nick's or Manouguian procedures. The estimated postoperative endpoints were mortality, effective orifice areas (EOA), mean aortic pressure gradient (PG), and valve-related complications. The shortest postoperative follow-up period was 6 months. Results: The study included 30 male and 70 female patients with mean age of 35 +/- 20 years, body surface area (BSA) of 1.7 +/- 0.3 m(2), aortic annulus diameter was 1.4 +/- 0.4 mm, aortic orifice area was 0.8 +/- 0.1 cm(2), and mean pressure gradient 85 +/- 2.5 mmHg. During the follow-up period, there was a mild to moderate paravalvular leak (1%) with 1% heart block and residual gradient on prosthetic aortic valve; this was all in DVR alone. Conclusion: Enlargement of the aortic root by Nick's or Manouguian technique is safe and effective in patients with small aortic annulus undergoing double valve replacements.
引用
收藏
页码:E239 / E242
页数:4
相关论文
共 50 条
  • [41] Loss of Independent Living in Patients Undergoing Transcatheter or Surgical Aortic Valve Replacement: A Retrospective Cohort Study
    Blank, Michael
    Robitaille, Mark J. J.
    Wachtendorf, Luca J. J.
    Linhardt, Felix C. C.
    Ahrens, Elena
    Strom, Jordan B. B.
    Azimaraghi, Omid
    Schaefer, Maximilian S. S.
    Chu, Louis M. M.
    Moon, Jee-Young
    Tarantino, Nicola
    Nair, Singh R. R.
    Thalappilil, Richard
    Tam, Christopher W. W.
    Leff, Jonathan
    Di Biase, Luigi
    Eikermann, Matthias
    ANESTHESIA AND ANALGESIA, 2023, 137 (03): : 618 - 628
  • [42] Aortic valve replacement in the calcified small aortic root by hemitranslocation of the valve
    Endo, M
    Nishida, H
    Chikazawa, G
    Tomizawa, Y
    ARTIFICIAL ORGANS, 2002, 26 (05) : 483 - 486
  • [43] POSTERIOR ENLARGEMENT OF THE SMALL ANNULUS DURING AORTIC-VALVE REPLACEMENT VERSUS IMPLANTATION OF A SMALL PROSTHESIS
    PUGLIESE, P
    BERNABEI, M
    SANTI, C
    PASQUE, A
    EUFRATE, S
    ANNALS OF THORACIC SURGERY, 1984, 38 (01): : 31 - 36
  • [44] Complicated Aortic Root Enlargement in a Patient Who Underwent Aortic Valve Replacement
    Shojaeifard, Maryam
    Salehi, Pegah
    Akbarian, Mahsa
    Mohebbi, Somayeh
    Alavi, Maryam
    Aliabadi, Leyla
    Shemshadi, Sara
    Hosseini, Saied
    RESEARCH IN CARDIOVASCULAR MEDICINE, 2023, 12 (03) : 98 - 101
  • [45] Aortic annulus rupture during transcatheter aortic valve implantation: safe aortic root replacement
    Eker, Armand
    Sozzi, Fabiola B.
    Civaia, Filippo
    Bourlon, Francois
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (05) : 1205 - 1205
  • [46] Aortic Valve Replacement in Elderly Patients With Small Aortic Annulus: Results With Three Different Bioprostheses
    Chiariello, Giovanni A.
    Bruno, Piergiorgio
    Villa, Emmanuel
    Pasquini, Annalisa
    Pavone, Natalia
    Cammertoni, Federico
    Mazza, Andrea
    Colizzi, Christian
    Nesta, Marialisa
    Iafrancesco, Mauro
    Perri, Gianluigi
    Messina, Antonio
    Troise, Giovanni
    Massetti, Massimo
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (01) : 27 - 36
  • [47] Aortic Root Dimensions Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement
    Buellesfeld, Lutz
    Stortecky, Stefan
    Kalesan, Bindu
    Gloekler, Steffen
    Khattab, Ahmed A.
    Nietlispach, Fabian
    Delfine, Valentina
    Huber, Christoph
    Eberle, Balthasar
    Meier, Bernhard
    Wenaweser, Peter
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) : 72 - 83
  • [48] Enlargement of the aortic annulus with glutaraldehyde-fixed bovine pericardium during aortic valve replacement
    Bortolotti, U
    Scioti, G
    Milano, A
    Nardi, C
    Tartarini, G
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (03): : 299 - 304
  • [49] Small aortic root. Challenge for aortic valve replacement
    Misfeld, M.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2019, 33 (02): : 84 - 88
  • [50] Transcatheter Aortic Valve Replacement versus Sutureless Aortic Valve Replacement: A Single Center Retrospective Cohort Study
    Chung, Young Hak
    Lee, Seung Hyun
    Ko, Young-Guk
    Lee, Sak
    Shim, Chi-Young
    Ahn, Chul-Min
    Hong, Geu-Ru
    Shim, Jae-Kwang
    Kwak, Young-Lan
    Hong, Myeong-Ki
    YONSEI MEDICAL JOURNAL, 2021, 62 (10) : 885 - 894