Aortic Root Enlargement in Patients With Small Aortic Annulus Undergoing Double Valve Replacement: A Retrospective Comparative Cohort Study

被引:2
|
作者
Mubarak, Yasser Shaban [1 ,2 ]
Jawad, Ahmed Abdel Rahman Abdel [3 ,4 ]
机构
[1] Menia Univ, Dept Cardiothorac Surg, Al Minya, Egypt
[2] King Fahad Cent Hosp, Madinah Cardiac Ctr, Dammam, Saudi Arabia
[3] Cairo Univ, Dept Cardiothorac Surg, Cairo, Egypt
[4] Stadt Klinikum Braunschweig, Clin Cardiothorac & Vasc Surg, Braunschweig, Germany
来源
HEART SURGERY FORUM | 2021年 / 24卷 / 02期
关键词
Aortic Root Enlargement; Small Aortic Annulus; Double Valve Replacement; Patient-Prosthesis Mismatch; Nick's / Manouguian procedure; RISK;
D O I
10.1532/hsf.3401
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Small aortic annulus (AA) is a big issue during aortic valve replacement (AVR), necessitating replacement of an undersized prosthetic valve especially with double valve replacement (DVR). Despite the fact that small aortic valve prostheses can lead to prosthesis-patient mismatch (PPM), there remains reluctance to perform aortic root enlargement (ARE) procedures, fearing morbidity and mortality. Objective: To evaluate clinical and echocardiographic outcomes in patients with small aortic annulus (<18 mm) undergoing double valve replacement. Methods: The study included 100 consecutive patients who underwent DVR for combined rheumatic aortic and mitral valve diseases, between January 2016 and September 2020. Only 50 patients had ARE with DVR. ARE was performed using an autologous or bovine pericardium or Dacron patch by Nick's or Manouguian procedures. The estimated postoperative endpoints were mortality, effective orifice areas (EOA), mean aortic pressure gradient (PG), and valve-related complications. The shortest postoperative follow-up period was 6 months. Results: The study included 30 male and 70 female patients with mean age of 35 +/- 20 years, body surface area (BSA) of 1.7 +/- 0.3 m(2), aortic annulus diameter was 1.4 +/- 0.4 mm, aortic orifice area was 0.8 +/- 0.1 cm(2), and mean pressure gradient 85 +/- 2.5 mmHg. During the follow-up period, there was a mild to moderate paravalvular leak (1%) with 1% heart block and residual gradient on prosthetic aortic valve; this was all in DVR alone. Conclusion: Enlargement of the aortic root by Nick's or Manouguian technique is safe and effective in patients with small aortic annulus undergoing double valve replacements.
引用
收藏
页码:E239 / E242
页数:4
相关论文
共 50 条
  • [31] Comparative Safety and Effectiveness of Transcatheter Aortic Valve Replacement and Surgical Aortic Valve Replacement in Patients With a Small Aortic Annulus: A Systematic Review and Meta-Analysis
    Madanat, Luai
    Ayyad, Mohammed
    Al-Abdouh, Ahmad
    Mhanna, Mohammed
    Alhuneafat, Laith
    Obeidat, Liyan
    Alqarqaz, Mohammad
    Hanson, Ivan
    Abbas, Amr
    Frisoli, Tiberio
    Villablanca, Pedro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B365 - B366
  • [32] Postoperative Inflammation and Fever After Elective Aortic Valve and Aortic Root Replacement: A Retrospective Cohort Study
    Keijmel, Stephan P.
    Zwartkruis, Iris M. M.
    Jongenotter, Jochem
    Geuzebroek, Guillaume S. C.
    Kouijzer, Ilse J. E.
    OPEN FORUM INFECTIOUS DISEASES, 2023, 10 (01):
  • [33] Outcomes of aortic root enlargement during isolated aortic valve replacement
    Shih, Emily
    DiMaio, J. Michael
    Squiers, John J.
    Rahimighazikalayeh, Gelareh
    Meidan, Talia C.
    Brinkman, William T.
    Harrington, Katherine B.
    Schaffer, Justin M.
    Ryan, William H.
    Mack, Michael J.
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (08) : 2389 - 2394
  • [34] Impact of Aortic Annulus Enlargement on the Outcomes of Aortic Valve Replacement: A Meta-analysis
    Pompeu, Michel
    Zhigalov, Konstantin
    Cavalcanti, Luiz Rafael P.
    Escorel Neto, Antonio C.
    Rayol, Sergio C.
    Weymann, Alexander
    Ruhparwar, Arjang
    Lima, Ricardo C.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (02) : 316 - 325
  • [35] Annulus root enlargement during redo aortic valve replacement: Perioperative results and hemodynamic impact
    Chauvette, Vincent
    Senechal, Mario
    Barrette, Vincent
    Dagenais, Francois
    Mohammadi, Siamak
    Kalavrouziotis, Dimitri
    Voisine, Pierre
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (09) : 2158 - 2164
  • [36] SIMPLE INTERRUPTED SUTURING FOR AORTIC VALVE REPLACEMENT IN A SMALL AORTIC ANNULUS
    Kim, Jong Hun
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (06): : 2001 - 2001
  • [37] Sutureless Versus Stented Valve in Aortic Valve Replacement in Patients With Small Annulus
    Shalabi, Amjad
    Spiegelstein, Dan
    Sternik, Leonid
    Feinberg, Micha S.
    Kogan, Alexander
    Levin, Shany
    Orlov, Boris
    Nachum, Eyal
    Lipey, Alexander
    Raanani, Ehud
    Hicks, George L., Jr.
    ANNALS OF THORACIC SURGERY, 2016, 102 (01): : 118 - 123
  • [38] Surgical aortic valve replacement optimizing the small aortic annulus size
    Bortolotti, Uberto
    Vendramin, Igor
    Livi, Ugolino
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (03)
  • [39] MANAGEMENT OF SMALL AORTIC ANNULUS IN THE ERA OF SUTURELESS AORTIC VALVE REPLACEMENT
    Ghoneim, A.
    Mazine, A.
    Bouhout, I.
    Bouchard, D.
    Pellerin, M.
    Perrault, L. P.
    Cattier, R.
    Demers, P.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S223 - S223
  • [40] Transcatheter Aortic Valve Replacement in Patients With a Small Aortic Annulus: Results From Two Prospective Cohort Studies in China
    Hu, Xiangming
    Wang, Moyang
    Zhang, Hongliang
    Chen, Yang
    Niu, Guannan
    Ye, Yunqing
    Zhou, Zheng
    Feng, Dejing
    Wu, Yongjian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B369 - B370