Applicability of ISNT Rule Using BMO-MRW to Differentiate Between Healthy and Glaucomatous Eyes

被引:12
|
作者
Park, Do Young [1 ]
Lee, Eun Jung [1 ]
Han, Jong Chul [1 ]
Kee, Changwon [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Ophthalmol, 81 Irwon Ro, Seoul 06351, South Korea
关键词
ISNT rule; Bruch's membrane opening minimum rim width (BMO-MRW); diagnostic ability; normal tension glaucoma; myopia; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; NERVE-FIBER LAYER; SCANNING LASER TOMOGRAPHY; NORMAL-TENSION GLAUCOMA; NEURORETINAL RIM; TILTED DISCS; MYOPIC EYES; BEIJING EYE; POPULATION;
D O I
10.1097/IJG.0000000000000970
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:We evaluated the applicability of the ISNT rule using Bruch's membrane opening minimum rim width (BMO-MRW) in healthy eyes and eyes with normal tension glaucoma (NTG).Materials and Methods:In total, 124 healthy eyes and 136 NTG eyes were analyzed. Using 2-dimensional disc photographs, neuroretinal rim (NRR) thickness was measured at the superior, inferior, nasal, and temporal sides of the optic disc. Using spectral domain-optical coherence tomography, BMO-MRW was measured at the same regions. We compared the applicability of the ISNT rule in healthy and NTG eyes between these 2 methods. If the NRR was not clearly distinguished on disc photographs, the eye was classified into the indistinguishable NRR group and we only tested applicability of the ISNT rule using BMO-MRW.Results:The specificity of violation of the ISNT rule for the diagnosis of glaucoma was higher when BMO-MRW was used (66.3%) than using disc photographs (42.2%), whereas the sensitivity did not show a significant difference between the 2 methods (91.7% vs. 86.5%). Compared with eyes with distinguishable NRR (179 eyes), eyes with indistinguishable NRR (81 eyes) had higher axial length, more negative refractive error, and higher tilt ratio (P<0.001). The diagnostic ability of violation of ISNT rule using BMO-MRW was not significantly different between eyes with indistinguishable NRR and those with distinguishable NRR (P>0.05).Conclusions:Application of the ISNT rule using BMO-MRW shows superiority in distinguishing between healthy and glaucomatous optic discs compared with disc photographs. The ISNT rule can be applied using BMO-MRW even when NRR is indistinguishable on disc photographs, such as in myopic tilted discs.
引用
收藏
页码:610 / 616
页数:7
相关论文
共 50 条
  • [41] Discrimination Between Healthy Eyes and Those With Mild Glaucoma Damage Using Hemoglobin Measurements of the Optic Nerve Head
    de Meneses, Livia Studart
    Ciarlini, Lorena Ribeiro
    Ayub, Gabriel
    Vasconcellos, Jose Paulo C.
    Costa, Vital Paulino
    JOURNAL OF GLAUCOMA, 2022, 31 (07) : 567 - 573
  • [42] Using functional Magnetic Resonance Imaging to differentiate between healthy aging subjects, Mild Cognitive Impairment, and Alzheimer's patients
    Oghabian, Mohammad Ali
    Batouli, Seyed Amir Hossein
    Norouzian, Maryam
    Ziaei, Maryam
    Sikaroodi, Hajir
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2010, 15 (02): : 84 - 93
  • [43] Advanced Analysis of OCT/OCTA Images for Accurately Differentiating Between Glaucoma and Healthy Eyes Using Deep Learning Techniques
    Pourjavan, Sayeh
    Gouverneur, Francois
    Macq, Benoit
    Van Drooghenbroeck, Thomas
    De Potter, Patrick
    Boschi, Antonella
    El Maftouhi, Adil
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3493 - 3502
  • [44] Distance between the center of the FAZ measured automatically and the highest foveal bulge using OCT-angiography in elderly healthy eyes
    Shoji, Takuhei
    Ishii, Hirokazu
    Kanno, Junji
    Sasaki, Takanori
    Yoshikawa, Yuji
    Ibuki, Hisashi
    Shinoda, Kei
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [45] Distance between the center of the FAZ measured automatically and the highest foveal bulge using OCT-angiography in elderly healthy eyes
    Takuhei Shoji
    Hirokazu Ishii
    Junji Kanno
    Takanori Sasaki
    Yuji Yoshikawa
    Hisashi Ibuki
    Kei Shinoda
    Scientific Reports, 11
  • [46] Comparison of diagnosis accuracy of the ganglion cell complex thickness in the 7-degree inclined versus horizontalized 8x8 grid of the posterior pole algorithm to distinguish between healthy and glaucomatous eyes
    Del-Rio-Vellosillo, Monica
    Alvarez-Sarrion, Aurora
    Dolores Lopez-Bernal, Maria
    Rubio-Velazquez, Elena
    Pinazo-Duran, Maria D.
    Javier Garcia-Medina, Jose
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [47] Discrimination between glaucomatous and non-glaucomatous eyes of black and white subjects using quantitative optic disc topography (OCT III and HRT II), retinal nerve fiber layer analysis (OCT III and GDx-VCC), and subjective optic disc assessment
    Girkin, CA
    Xie, A
    McGwin, G
    Ortega, JD
    Monhiet, B
    Arthur, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [49] The applicability limits of using the additivity rule for Gibbs energy increments of functional groups in describing and predicting the distribution of organic nonelectrolytes between n-octane and water
    Leshchev, SM
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2002, 76 (10): : 1597 - 1603
  • [50] Quantifizierung der retinalen Nervenfaserschichtdicke — gemessen mit dem Nerve Fiber Analyzer (NFA) bei gesunden und glaukomkranken AugenQuantitative assessment of the retinal nerve fiber layer in glaucomatous versus healthy eyes using the Nerve Fiber Analyzer
    Maren Klemm
    E. Rumberger
    G. Richard
    Spektrum der Augenheilkunde, 2000, 14 (3) : 146 - 151