Applicability of ISNT Rule Using BMO-MRW to Differentiate Between Healthy and Glaucomatous Eyes

被引:12
|
作者
Park, Do Young [1 ]
Lee, Eun Jung [1 ]
Han, Jong Chul [1 ]
Kee, Changwon [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Ophthalmol, 81 Irwon Ro, Seoul 06351, South Korea
关键词
ISNT rule; Bruch's membrane opening minimum rim width (BMO-MRW); diagnostic ability; normal tension glaucoma; myopia; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; NERVE-FIBER LAYER; SCANNING LASER TOMOGRAPHY; NORMAL-TENSION GLAUCOMA; NEURORETINAL RIM; TILTED DISCS; MYOPIC EYES; BEIJING EYE; POPULATION;
D O I
10.1097/IJG.0000000000000970
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:We evaluated the applicability of the ISNT rule using Bruch's membrane opening minimum rim width (BMO-MRW) in healthy eyes and eyes with normal tension glaucoma (NTG).Materials and Methods:In total, 124 healthy eyes and 136 NTG eyes were analyzed. Using 2-dimensional disc photographs, neuroretinal rim (NRR) thickness was measured at the superior, inferior, nasal, and temporal sides of the optic disc. Using spectral domain-optical coherence tomography, BMO-MRW was measured at the same regions. We compared the applicability of the ISNT rule in healthy and NTG eyes between these 2 methods. If the NRR was not clearly distinguished on disc photographs, the eye was classified into the indistinguishable NRR group and we only tested applicability of the ISNT rule using BMO-MRW.Results:The specificity of violation of the ISNT rule for the diagnosis of glaucoma was higher when BMO-MRW was used (66.3%) than using disc photographs (42.2%), whereas the sensitivity did not show a significant difference between the 2 methods (91.7% vs. 86.5%). Compared with eyes with distinguishable NRR (179 eyes), eyes with indistinguishable NRR (81 eyes) had higher axial length, more negative refractive error, and higher tilt ratio (P<0.001). The diagnostic ability of violation of ISNT rule using BMO-MRW was not significantly different between eyes with indistinguishable NRR and those with distinguishable NRR (P>0.05).Conclusions:Application of the ISNT rule using BMO-MRW shows superiority in distinguishing between healthy and glaucomatous optic discs compared with disc photographs. The ISNT rule can be applied using BMO-MRW even when NRR is indistinguishable on disc photographs, such as in myopic tilted discs.
引用
收藏
页码:610 / 616
页数:7
相关论文
共 50 条
  • [21] Assessment of Choroidal Thickness in Healthy and Glaucomatous Eyes Using Swept Source Optical Coherence Tomography
    Zhang, Chunwei
    Tatham, Andrew J.
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Yang, Zhiyong
    Weinreb, Robert N.
    PLOS ONE, 2014, 9 (10):
  • [22] Comparisons of Nerve Fiber Layer Thickness Measurements between Stratus, Cirrus, and RTVue OCTs in Healthy and Glaucomatous Eyes
    Lee, Eun Suk
    Kang, Sung Yong
    Choi, Eun Hee
    Kim, Ji Hyun
    Kim, Na Rae
    Seong, Gong Je
    Kim, Chan Yun
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (06) : 751 - 758
  • [23] Preliminary study on differentiation between glaucomatous and non-glaucomatous eyes on stereo fundus images using cup gradient models
    Muramatsu, Chisako
    Hatanaka, Yuji
    Ishida, Kyoko
    Sawada, Akira
    Yamamoto, Tetsuya
    Fujita, Hiroshi
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [24] Pointwise correlations between different intraretinal layer thicknesses and retinal sensitivity as assessed by OCT and microperimetry in healthy and glaucomatous eyes
    Javier Garcia-Medina, Jose
    Lopez-Canovas, Lorena
    Zanon-Moreno, Vicente
    Pinazo-Duran, Maria D.
    Del-Rio-Vellosillo, Monica
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [25] Perimetry Instrument Comparison Study: Between Test Variability of Four Threshold Perimetry Tests in Healthy and 'Glaucomatous' Eyes (Interim Analysis)
    Sinapis, A.
    Bergin, C.
    Sinapis, D.
    Russell, R. A.
    Moosavi, R.
    Balian, C.
    Verdon-Roe, G. M.
    Flanagan, J.
    Crabb, D. P.
    Garway-Heath, D. F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [26] Comparison between peripapillary choroidal thickness and retinal nerve fiber layer (RNFL) damage in healthy, ocular hypertension and glaucomatous eyes
    Gerace, Emanuele
    Cutini, Alessandro
    Fragiotta, Serena
    Marenco, Marco
    Verboschi, Francesca
    Carnevale, Carmela
    Vingolo, Enzo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [27] Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects
    Hsin-Yi Chen
    Mei-Ling Huang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 894 - 902
  • [28] Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects
    Chen, HY
    Huang, ML
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (09) : 894 - 902
  • [29] Quantification fi cation and Predictors of Visual Field Variability in Healthy, Glaucoma Suspect, and Glaucomatous Eyes Using SITA-Faster
    Tan, Jeremy C. K.
    Agar, Ashish
    Kalloniatis, Michael
    Phu, Jack
    OPHTHALMOLOGY, 2024, 131 (06) : 658 - 666
  • [30] Perimetry Instrument Comparison Study: Comparing the 'Screening' Strategies of Three Perimetry Devices to Discriminate Between Healthy and 'Glaucomatous' Eyes (Interim Results)
    Bergin, C.
    Sinapis, D.
    Sinapis, A.
    Moosavi, R.
    Verdon-Roe, G. M.
    Crabb, D. P.
    Garway-Heath, D. F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)