Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

被引:7
|
作者
Kim, Ho Chul [1 ]
Kim, Hee-Joung [2 ]
Kim, Kyuseok [2 ]
Lee, Min-Hee [3 ]
Lee, Youngjin [1 ]
机构
[1] Eulji Univ, Dept Radiol Sci, 553 Sanseong Daero, Seongnam Si 13135, Gyeonggi Do, South Korea
[2] Yonsei Univ, Dept Radiol Sci, 1 Yonseidae Gil, Wonju 26493, South Korea
[3] Yonsei Univ, Dept Biomed Engn, 1 Yonseidae Gil, Wonju 26493, South Korea
关键词
Medical Application; Monte Carlo Simulation; Nuclear Medicine; Photon Counting Detector; Scintillation Detector; Single-Photon Emission Computed Tomography System; PARALLEL-HOLE COLLIMATOR; GAMMA-CAMERA; PERFORMANCE EVALUATION; SPECT; RESOLUTION; DETECTORS; CDTE;
D O I
10.1016/j.net.2016.12.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a Tc-99m gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector. (C) 2017 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:776 / 780
页数:5
相关论文
共 50 条
  • [41] Single-photon emission computed tomography and developmental disorders of the neocortex
    Spalice, A
    Raucci, U
    Atzei, G
    Boemi, S
    Iannetti, P
    ANNALS OF NEUROLOGY, 1996, 40 (02) : 52 - 52
  • [42] Single-Photon Emission Computed Tomography (SPECT) and Intractable Epilepsy
    Tikkakoski, Tapani
    ACTA RADIOLOGICA, 2009, 50 (10) : 1094 - 1094
  • [43] Single-photon emission computed tomography in a proportional scattering medium
    S. A. Tereshchenko
    Technical Physics, 2017, 62 : 1293 - 1299
  • [44] Radiopharmaceuticals for single-photon emission computed tomography brain imaging
    Kung, HF
    Kung, MP
    Choi, SR
    SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (01) : 2 - 13
  • [45] PET and Single-Photon Emission Computed Tomography in Brain Concussion
    Raji, Cyrus A.
    Henderson, Theodore A.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2018, 28 (01) : 67 - +
  • [46] Advances in Single-Photon Emission Computed Tomography Hardware and Software
    Piccinelli, Marina
    Garcia, Ernest V.
    CARDIOLOGY CLINICS, 2016, 34 (01) : 1 - +
  • [47] IMAGE FUSION OF SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY AND COMPUTED TOMOGRAPHY SCAN IN CANINE INSULIMONA: 10 CASES
    Pineiro, Isabel Rodriguez
    Delisle, F.
    Devauchelle, Patrick
    Rosenberg, Dan
    de Fornel-Thibaud, Pauline
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (03) : 680 - 680
  • [48] PHOTON PROPAGATION AND DETECTION IN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - AN ANALYTICAL APPROACH
    RIAUKA, TA
    GORTEL, ZW
    MEDICAL PHYSICS, 1994, 21 (08) : 1311 - 1321
  • [49] Positron emission tomography and single-photon emission computed tomography in central nervous system drug development
    Brooks D.J.
    NeuroRX, 2005, 2 (2): : 226 - 236
  • [50] Monte Carlo simulation and implementation of photon counting image based on APD
    Yin, Li-Ju
    Chen, Qian
    Gu, Guo-Hua
    Gong, Si-Xia
    Nanjing Li Gong Daxue Xuebao/Journal of Nanjing University of Science and Technology, 2010, 34 (05): : 649 - 652