Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

被引:7
|
作者
Kim, Ho Chul [1 ]
Kim, Hee-Joung [2 ]
Kim, Kyuseok [2 ]
Lee, Min-Hee [3 ]
Lee, Youngjin [1 ]
机构
[1] Eulji Univ, Dept Radiol Sci, 553 Sanseong Daero, Seongnam Si 13135, Gyeonggi Do, South Korea
[2] Yonsei Univ, Dept Radiol Sci, 1 Yonseidae Gil, Wonju 26493, South Korea
[3] Yonsei Univ, Dept Biomed Engn, 1 Yonseidae Gil, Wonju 26493, South Korea
关键词
Medical Application; Monte Carlo Simulation; Nuclear Medicine; Photon Counting Detector; Scintillation Detector; Single-Photon Emission Computed Tomography System; PARALLEL-HOLE COLLIMATOR; GAMMA-CAMERA; PERFORMANCE EVALUATION; SPECT; RESOLUTION; DETECTORS; CDTE;
D O I
10.1016/j.net.2016.12.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a Tc-99m gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector. (C) 2017 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:776 / 780
页数:5
相关论文
共 50 条
  • [21] Single-photon emission computed tomography findings in schizophrenia
    Catafau, AM
    Lomena, FJ
    Parellada, E
    Bernardo, M
    IMMUNOLOGICAL ALTERATIONS IN PSYCHIATRIC DISEASES, 1997, 18 : 90 - 95
  • [22] BRAIN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    MASDEU, JC
    BRASS, LM
    HOLMAN, BL
    KUSHNER, MJ
    NEUROLOGY, 1994, 44 (10) : 1970 - 1977
  • [23] Quantitative single-photon emission computed tomography imaging
    Germano G.
    Berman D.S.
    Current Cardiology Reports, 2005, 7 (2) : 136 - 142
  • [24] Energy window and collimator optimization in lutetium-177 single-photon emission computed tomography imaging using Monte Carlo simulation
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    Douama, Sanae
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 35 (01): : 36 - 39
  • [25] Numerical Simulation of Single-Photon Emission Computed Tomography in a Proportional Scattering Medium
    Lysenko, A. Yu
    Tereshchenko, S. A.
    XIV RUSSIAN-GERMANY CONFERENCE ON BIOMEDICAL ENGINEERING (RGC-2019), 2019, 2140
  • [26] Myocardial Perfusion Single-Photon Emission Computed Tomography (SPECT) Image Denoising: A Comparative Study
    Rahimian, Abdurrahim
    Etehadtavakol, Mahanaz
    Moslehi, Masoud
    Ng, Eddie Y. K.
    DIAGNOSTICS, 2023, 13 (04)
  • [27] Study of novel deformable image registration in myocardial perfusion single-photon emission computed tomography
    Ito, Toshimune
    Onoguchi, Masahisa
    Okuda, Koichi
    Shibutani, Takayuki
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (03) : 196 - 205
  • [28] Single-photon emission computed tomography/computed tomography: Basic instrumentation and innovations
    O'Connor, Michael K.
    Kemp, Brad J.
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 258 - 266
  • [29] Single-photon emission computed tomography-computed tomography in imaging infection
    Navalkissoor, Shaunak
    Nowosinska, Ewa
    Gnanasegaran, Gopinath
    Buscombe, John R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (04) : 283 - 290
  • [30] Technological development and advances in single-photon emission computed tomography/computed tomography
    Seo, Youngho
    Mari, Carina
    Hasegawa, Bruce H.
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 177 - 198