Application of selected fundamental parameters in x-ray fluorescence analysis

被引:1
|
作者
Zhuo, SJ [1 ]
Tao, GY [1 ]
Ji, A [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
关键词
D O I
10.1002/xrs.611
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The effectiveness of selected fundamental parameters in x-ray fluorescence analysis previously proposed by the authors was examined with a few examples. Some synthetic fused binary disks were prepared and measured to obtain the measured binary coefficients. The theoretical influence coefficients were also calculated based on the synthetic specimens and measuring conditions using those selected fundamental parameters and compared with the measured values. It was found that the theoretical influence coefficients calculated with selected fundamental parameters agreed better with measured values than those calculated with original parameters. The synthetic fused disks, some Au-Ag-Cu alloys and some Chinese rock reference materials were measured and quantitatively calculated with the program NRLXRF, that uses original parameters, and with NRL301, that uses selected fundamental parameters, using only one calibration standard for fused disks and only pure elements for alloys. The relative errors of the results from NRL301 are much smaller than those from NRLXRF. Data for the example of pressed powders of cement published in an NBS Technical Note were also calculated with NRL301 with one calibration standard. The results are comparable to those from NBSGSC obtained with seven calibration standards. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [41] Application of X-Ray Fluorescence Analysis in Investigations of Historical Monuments
    Cechak, T.
    Musilek, L.
    Trojek, T.
    Kopecka, I.
    ACTA POLYTECHNICA, 2005, 45 (05) : 48 - 51
  • [42] Forensic application of synchrotron radiation X-ray fluorescence analysis
    Nakai, I
    Terada, Y
    Ninomiya, T
    16TH MEETING OF THE INTERNATIONAL ASSOCIATION OF FORENSIC SCIENCES, 2002, : 29 - 34
  • [43] An Application of Lucy Richardson Iterative in X-Ray Fluorescence Analysis
    Zhu Yu-xuan
    Lu Jing-bin
    Zhao Xiao-fan
    Liu Xiao-yan
    Cui Wei-wei
    Li Wei
    Wang Yu-sa
    Lu Zhong-hua
    Chen Yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (09) : 2823 - 2828
  • [44] X-RAY FLUORESCENCE ANALYSIS AND ITS APPLICATION TO COPPER ALLOYS
    BAREHAM, FR
    FOX, JGM
    JOURNAL OF THE INSTITUTE OF METALS, 1960, 88 (08): : 344 - 351
  • [45] Measurements of K x-ray fluorescence parameters
    Bennal, AS
    Shidling, PD
    Badiger, NM
    Thontadarya, SR
    Hanumaiah, B
    AMERICAN JOURNAL OF PHYSICS, 2005, 73 (09) : 883 - 887
  • [46] Study of the monolithic x-ray focusing lens and its application in microbeam x-ray fluorescence analysis
    Xie, JD
    Yan, YM
    Ding, XL
    He, YJ
    Pan, QL
    X-RAY SPECTROMETRY, 2000, 29 (04) : 305 - 309
  • [47] Indirect method for the determination of x-ray tube primary spectra: application to x-ray fluorescence analysis
    Delgado, V
    X-RAY SPECTROMETRY, 2002, 31 (05) : 353 - 357
  • [48] USE OF INDIRECTLY MEASURED SPECTRA IN FUNDAMENTAL PARAMETERS X-RAY-FLUORESCENCE ANALYSIS
    RUBIO, M
    MAINARDI, RT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (1-2): : 403 - 410
  • [49] VERSATILE X-RAY ANALYSIS PROGRAM COMBINING FUNDAMENTAL PARAMETERS AND EMPIRICAL COEFFICIENTS
    CRISS, JW
    BIRKS, LS
    GILFRICH, JV
    ANALYTICAL CHEMISTRY, 1978, 50 (01) : 33 - 37
  • [50] Glancing angle X-ray fluorescence and its application in X-ray technic
    Dudchik, YI
    Komarov, FF
    Konstantinov, YA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 298 - 306