Application of selected fundamental parameters in x-ray fluorescence analysis

被引:1
|
作者
Zhuo, SJ [1 ]
Tao, GY [1 ]
Ji, A [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
关键词
D O I
10.1002/xrs.611
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The effectiveness of selected fundamental parameters in x-ray fluorescence analysis previously proposed by the authors was examined with a few examples. Some synthetic fused binary disks were prepared and measured to obtain the measured binary coefficients. The theoretical influence coefficients were also calculated based on the synthetic specimens and measuring conditions using those selected fundamental parameters and compared with the measured values. It was found that the theoretical influence coefficients calculated with selected fundamental parameters agreed better with measured values than those calculated with original parameters. The synthetic fused disks, some Au-Ag-Cu alloys and some Chinese rock reference materials were measured and quantitatively calculated with the program NRLXRF, that uses original parameters, and with NRL301, that uses selected fundamental parameters, using only one calibration standard for fused disks and only pure elements for alloys. The relative errors of the results from NRL301 are much smaller than those from NRLXRF. Data for the example of pressed powders of cement published in an NBS Technical Note were also calculated with NRL301 with one calibration standard. The results are comparable to those from NBSGSC obtained with seven calibration standards. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [21] X-ray fluorescence analysis by the fundamental parameters method without explicit knowledge of the excitation beam spectrum
    Martínez, VD
    Hidalgo, CM
    Barrea, RA
    X-RAY SPECTROMETRY, 2000, 29 (03) : 245 - 248
  • [22] Development and Applications of a Fundamental Parameter Method for X-ray Fluorescence Analysis
    Kataoka, Yoshiyuki
    Kohno, Hisayuki
    Kawahara, Naoki
    Ochi, Hirotomo
    Nishino, Makoto
    Nakamura, Hideki
    BUNSEKI KAGAKU, 2020, 69 (7-8) : 363 - 371
  • [23] Accuracy of the fundamental parameter method for x-ray fluorescence analysis of rocks
    Borkhodoev, VY
    X-RAY SPECTROMETRY, 2002, 31 (03) : 209 - 218
  • [24] APPLICATION OF METHOD OF ADDITIONS IN X-RAY FLUORESCENCE ANALYSIS
    BRODKORB, E
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1969, 246 (05): : 289 - &
  • [25] FLINT X-RAY FLUORESCENCE ANALYSIS FOR GEOARCHAEOLOGICAL APPLICATION
    Zarina, Liga
    Kostjukovs, Juris
    Seglins, Valdis
    Burlakovs, Juris
    GEOCONFERENCE ON SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, VOL I, 2014, : 79 - 86
  • [26] Cryogenic detectors and their application to x-ray fluorescence analysis
    Frank, Matthias
    Friedrich, Stephan
    Hoehne, Jens
    Jochum, Josef
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2003, 11 (02) : 83 - 112
  • [27] APPLICATION OF X-RAY FLUORESCENCE METHODS TO THE ANALYSIS OF ZIRCALOY
    ASHLEY, RW
    JONES, RW
    ANALYTICAL CHEMISTRY, 1959, 31 (10) : 1632 - 1635
  • [28] Application of X-ray fluorescence spectrometry to metallurgical analysis
    Gao, X.H.
    Ding, Z.Q.
    Kang T'ieh/Iron and Steel (Peking), 2001, 36 (03): : 64 - 68
  • [29] X-ray fluorescence analysis in archaeometry: Application and expectation
    Zhu Jian
    Mao Zhen-wei
    Zhang Shi-ding
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (12) : 2341 - 2345
  • [30] The present and future of microcalorimeter X-ray detectors for fundamental X-ray parameters
    Jach, Terrence
    Thurgate, Stephen
    Beckhoff, Burkhard