Intraoperative Correction of Cochlear Implant Electrode Translocation

被引:2
|
作者
Morrel, William G. [1 ]
Manzoor, Nauman F. [1 ]
Dawant, Benoit M. [2 ]
Noble, Jack H. [2 ]
Labadie, Robert F. [1 ,3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Otolaryngol Head & Neck Surg, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Elect Engn & Comp Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
关键词
Cochlear implantation; Translocation; Precurved electrodes; CI532;
D O I
10.1159/000515684
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Translocation of precurved cochlear implant (CI) electrodes reduces hearing outcomes, but it is not known whether it is possible to correct scalar translocation such that all electrodes reside fully in the scala tympani (ST). Methods: Six cadaveric temporal bones were scanned with CT and segmented to delineate intracochlear anatomy. Mastoidectomy with facial recess was performed. Precurved CI electrodes (CI532; Cochlear Limited) were implanted until scalar translocation was confirmed with postoperative CT. Then, electrodes were removed and replaced. CT scan was repeated to assess for translocation correction. Scalar position of electrode contacts, angular insertion depth (AID) of the electrode array, and M- (average distance between each electrode contact and the modiolus) were measured. An in vivo case is reported in which intraoperative translocation detection led to removal and replacement of the electrode. Results: Five of 6 cadaveric translocations (83%) were corrected with 1 attempt, resulting in full ST insertions. AID averaged 285 +/- 77 degrees for translocated electrodes compared to 344 +/- 28 degrees for nontranslocated electrodes (p = 0.109). M- averaged 0.75 +/- 0.18 mm for translocated electrodes and 0.45 +/- 0.11 mm for nontranslocated electrodes (p = 0.016). Reduction in M- with translocation correction averaged 38%. In the in vivo case, translocation was successfully corrected in a single attempt. Conclusion: Scalar translocation of precurved CI electrodes can be corrected by removal and reinsertion. This significantly improves the perimodiolar positioning of these electrodes. There was a high rate of success (83%) in this cadaveric model as well as a successful in vivo attempt.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [41] MULTIPLE-ELECTRODE ARRAY FOR A COCHLEAR IMPLANT
    CLARK, GM
    HALLWORTH, RJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1976, 90 (07): : 623 - 627
  • [42] Electrode Interaction in Pediatric Cochlear Implant Subjects
    Marc D. Eisen
    Kevin H. Franck
    Journal of the Association for Research in Otolaryngology, 2005, 6 : 160 - 170
  • [43] Hidden Electrode Failure in a Cochlear Implant User
    Gaertner, Lutz
    Buechner, Andreas
    Illg, Angelika
    Lenarz, Thomas
    LARYNGOSCOPE, 2021, 131 (04): : E1275 - E1278
  • [44] Cochlear Implant Electrode Placement and Music Perception
    Berg, Katelyn A.
    Noble, Jack H.
    Dawant, Benoit M.
    Sunderhaus, Linsey W.
    Defreese, Andrea J.
    Labadie, Robert F.
    Gifford, Rene H.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2025, 151 (03) : 220 - 227
  • [45] Advances to Electrode Pullback in Cochlear Implant Surgery
    Todt, Ingo
    Basta, Dietmar
    Seidl, Rainer
    Ernst, Arne
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [46] COCHLEAR IMPLANT ROUND WINDOW ELECTRODE ARRAY
    CLARK, GM
    PATRICK, JF
    BAILEY, Q
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1979, 93 (02): : 107 - 109
  • [47] Devellopment of a steerable cochlear implant electrode array
    Chen, B. K.
    Kha, H. N.
    Clark, G. M.
    3RD KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2006, 2007, 15 : 607 - +
  • [48] Electrode interaction in pediatric cochlear implant subjects
    Eisen, MD
    Franck, KH
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2005, 6 (02): : 160 - 170
  • [49] The Influence of Cochlear Implant Electrode Position on Performance
    van der Marel, Kim S.
    Briaire, Jeroen J.
    Verbist, Berit M.
    Muurling, Tjeerd J.
    Frijns, Johan H. M.
    AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (03) : 202 - 211
  • [50] Measuring the cochlea and cochlear implant electrode depth
    Jeffrey P. Guenette
    European Radiology, 2021, 31 : 1257 - 1259