Intraoperative Correction of Cochlear Implant Electrode Translocation

被引:2
|
作者
Morrel, William G. [1 ]
Manzoor, Nauman F. [1 ]
Dawant, Benoit M. [2 ]
Noble, Jack H. [2 ]
Labadie, Robert F. [1 ,3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Otolaryngol Head & Neck Surg, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Elect Engn & Comp Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
关键词
Cochlear implantation; Translocation; Precurved electrodes; CI532;
D O I
10.1159/000515684
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Translocation of precurved cochlear implant (CI) electrodes reduces hearing outcomes, but it is not known whether it is possible to correct scalar translocation such that all electrodes reside fully in the scala tympani (ST). Methods: Six cadaveric temporal bones were scanned with CT and segmented to delineate intracochlear anatomy. Mastoidectomy with facial recess was performed. Precurved CI electrodes (CI532; Cochlear Limited) were implanted until scalar translocation was confirmed with postoperative CT. Then, electrodes were removed and replaced. CT scan was repeated to assess for translocation correction. Scalar position of electrode contacts, angular insertion depth (AID) of the electrode array, and M- (average distance between each electrode contact and the modiolus) were measured. An in vivo case is reported in which intraoperative translocation detection led to removal and replacement of the electrode. Results: Five of 6 cadaveric translocations (83%) were corrected with 1 attempt, resulting in full ST insertions. AID averaged 285 +/- 77 degrees for translocated electrodes compared to 344 +/- 28 degrees for nontranslocated electrodes (p = 0.109). M- averaged 0.75 +/- 0.18 mm for translocated electrodes and 0.45 +/- 0.11 mm for nontranslocated electrodes (p = 0.016). Reduction in M- with translocation correction averaged 38%. In the in vivo case, translocation was successfully corrected in a single attempt. Conclusion: Scalar translocation of precurved CI electrodes can be corrected by removal and reinsertion. This significantly improves the perimodiolar positioning of these electrodes. There was a high rate of success (83%) in this cadaveric model as well as a successful in vivo attempt.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [1] Intraoperative Cochlear Implant Reinsertion Effects Evaluated by Electrode Impedance
    Toner, Fearghal M.
    Sanli, Halit
    Hall, Andrew C.
    Birman, Catherine S.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : E695 - E699
  • [2] Speech Performance Following Intraoperative Correction of Cochlear Implant Electrode Array Tip Fold-Overs
    Smetak, Miriam R.
    Shew, Matthew A.
    Varghese, Jordan
    Durakovic, Nedim
    Wick, Cameron C.
    Buchman, Craig A.
    Herzog, Jacques A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2025,
  • [3] Detection of Translocation of Cochlear Implant Electrode Arrays by Intracochlear Impedance Measurements
    Dong, Yu
    Briaire, Jeroen J.
    Siebrecht, Michael
    Stronks, H. Christiaan
    Frijns, Johan H. M.
    EAR AND HEARING, 2021, 42 (05): : 1397 - 1404
  • [4] Voltage Matrix Algorithm for Intraoperative Detection of Cochlear Implant Electrode Misplacement
    Franke-Trieger, Annett
    Lailach, Susen
    Strahl, Stefan B.
    Murrmann, Katrin
    Schebsdat, Erik
    Neudert, Marcus
    Zahnert, Thomas
    AUDIOLOGY AND NEUROTOLOGY, 2024,
  • [5] COCHLEAR IMPLANT ELECTRODE
    CLARK, GM
    HALLWORTH, RJ
    ZDANIUS, K
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1975, 89 (08): : 787 - 792
  • [6] Temporal Bone Histopathology of First-Generation Cochlear Implant Electrode Translocation
    Ishiyama, Akira
    Ishiyama, Gail
    Lopez, Ivan A.
    Linthicum, Fred H., Jr.
    OTOLOGY & NEUROTOLOGY, 2019, 40 (06) : E581 - E591
  • [7] Accuracy of intraoperative electrophysiological testing in confirming correct cochlear implant electrode positions
    Al Omari, Ahmad
    Nuseir, Amjad
    Ata, Majid Bani
    Khasawneh, Laith
    Alhowary, Ala A.
    Alzoubi, Firas
    COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (06) : 324 - 330
  • [8] Design of a Cochlear Implant Electrode
    Dhanasingh, Anandhan
    ENT UPDATES, 2022, 12 (02): : 97 - 109
  • [9] MULTIPLE ELECTRODE COCHLEAR IMPLANT
    CLARK, GM
    TONG, YC
    BLACK, R
    FORSTER, IC
    PATRICK, JF
    DEWHURST, DJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1977, 91 (11): : 935 - 945
  • [10] Cochlear Implant Insertion Axis Into the Basal Turn: A Critical Factor in Electrode Array Translocation
    Torres, Renato
    Drouillard, Mylene
    De Seta, Daniele
    Bensimon, Jean-Loup
    Ferrary, Evelyne
    Sterkers, Olivier
    Bernardeschi, Daniele
    Nguyen, Yann
    OTOLOGY & NEUROTOLOGY, 2018, 39 (02) : 168 - 176