Ventilation performance and indoor air quality in workstations under different supply air systems: A numerical approach

被引:6
|
作者
Jiang, Z
Haghighat, F
Chen, Q
机构
[1] Building Technology, Department of Architecture, Massachusetts Inst. of Technology, Cambridge, MA
[2] Centre for Building Studies, Concordia University, Montreal, Que.
[3] Centre for Building Studies, Concordia University, 1455 de Maisonneuve Blvd. W, Montreal
关键词
ventilation; indoor air quality; computational fluid dynamics; numerical approach; workstation;
D O I
10.1177/1420326X9700600306
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes the results of a computational fluid dynamics study to assess the air freshness and percentage of dissatisfied people due to air quality in a partitioned office with different supply air diffusers. The numerical model involves the finite-volume approach of solving governing equations for mass and momentum, assuming that the buoyancy effects are negligibly small in comparison to the inertial effects. The IC-E two-equation model of turbulence is used to predict the turbulence transport of flow properties. Two typical layouts that provide six individual workstations are studied. The results show that for displacement ventilation and wall jet diffusers, with the exhaust opening placed on the wall opposite to the supply opening, arranging chambers in the central area of the office may be better. When the exhaust opening is placed on the same wall as the supply diffuser, arranging chambers near side walls may be more favourable. The ceiling-mounted four-way diffuser is found to be more suitable for a partitioned office than the wall jet and displacement diffusers.
引用
收藏
页码:160 / 167
页数:8
相关论文
共 50 条
  • [21] Indoor Air Stratification in Warm Air Supply Systems
    Prozuments, Aleksejs
    Borodinecs, Anatolijs
    ASHRAE JOURNAL, 2017, 59 (11) : 54 - 65
  • [22] An Air Terminal Device with a Changing Geometry to Improve Indoor Air Quality for VAV Ventilation Systems
    Szczepanik-Scislo, Nina
    Schnotale, Jacek
    ENERGIES, 2020, 13 (18)
  • [23] PERCEIVED INDOOR AIR QUALITY RELATED TO VENTILATION RATES AND SCHOOL PERFORMANCE
    Badida, Miroslav
    Senitkov, Ingrid
    GEOCONFERENCE ON ENERGY AND CLEAN TECHNOLOGIES, 2013, : 733 - 740
  • [24] A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS
    Saheb, Hussien Aziz
    Mahdi, Ala'a Abbas
    Al-amir, Qusay Rasheed
    FRONTIERS IN HEAT AND MASS TRANSFER, 2021, 16
  • [25] Effect of quality and maintenance of the ventilation to the indoor air quality
    Niskanen, J
    Valkeapää, A
    Anttonen, H
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 168 - 171
  • [26] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [27] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [28] BUILDING VENTILATION AND INDOOR AIR-QUALITY
    BERK, JV
    AMERICAN CERAMIC SOCIETY BULLETIN, 1980, 59 (03): : 327 - 327
  • [29] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [30] Indoor air quality and the effects of displacement ventilation
    Fläkt Woods, Tufnell Way, Colchester CO4 5AR, United Kingdom
    Build. Eng., 2006, 1 (22-23):