X-ray tomography using a CMOS area detector

被引:1
|
作者
Brunetti, A.
Cesareo, R.
机构
[1] Univ Sassari, Dept Math & Phys, I-07100 Sassari, Italy
[2] Ist Nazl Fis Nucl, Sez Cagliari, Cagliari, Italy
关键词
flat panel; imaging; tomography;
D O I
10.1016/j.nimb.2007.02.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flat panel based on CMOS technology represents a valid alternative to other kinds of flat panels and to ccd detectors for X-ray imaging. Although the spatial resolution of the ccd sensors is better than that of a CMOS sensor, the last has a larger sensitive-area and it can work at room temperature reaching a dynamic performance comparable to that of a cooled ccd sensor. Other kinds of flat panels, such as TFT screen are much more expensive and they have lower spatial resolution and higher noise than the CMOS detector. In this paper, an application of the CMOS sensor to X-ray tomography is described. Preliminary results are reported and discussed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 50 条
  • [31] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [32] Assessment of parameters of digital X-ray detectors using the method of exposure of the working area of the detector to uniform X-ray radiation
    Mazurov A.I.
    Biomedical Engineering, 2007, 41 (5) : 218 - 219
  • [33] Conebeam X-ray computed tomography with an offset detector array
    Gregor, J
    Gleason, SS
    Paulus, MJ
    2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 803 - 806
  • [34] MicroComputed tomography with a photon-counting X-ray detector
    Frey, Ec.
    Taguchi, K.
    Kapusta, M.
    Xu, J.
    Orskaug, T.
    Ninive, I.
    Wagenaar, D.
    Patt, B.
    Tsui, B. M. W.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [35] A Vacuum Photoemission Detector for X-ray Tomography on the ITER Facility
    I. A. Barykov
    Yu. V. Gott
    M. M. Stepanenko
    Instruments and Experimental Techniques, 2004, 47 : 242 - 246
  • [36] Monolithically integrated X-ray detector arrays for computed tomography
    Sudharsanan, R
    Yoganathan, M
    Vakerlis, G
    Ferekides, CS
    McCandless, B
    Birkmire, R
    Deych, R
    Luhta, R
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 573 - 578
  • [37] Characterization of a spectroscopic detector for application in x-ray computed tomography
    Dooraghi, Alex A.
    Fix, Brian J.
    Smith, Jerel A.
    Brown, William D.
    Azevedo, Stephen G.
    Martz, Harry E.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [38] Bragg magnifier:: A detector for submicrometer x-ray computer tomography
    Stampanoni, M
    Borchert, G
    Abela, R
    Rüegsegger, P
    JOURNAL OF APPLIED PHYSICS, 2002, 92 (12) : 7630 - 7635
  • [39] A vacuum photoemission detector for X-ray tomography on the ITER facility
    Barykov, IA
    Gott, YV
    Stepanenko, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2004, 47 (02) : 242 - 246
  • [40] Characteristics of a silicon detector for industrial X-ray computed tomography
    Nucl Instrum Methods Phys Res Sect A, 1-3 (97):