Influence of bone architecture on the primary stability of different mini-implant designs

被引:21
|
作者
da Cunha, Amanda Carneiro [1 ]
Marquezan, Mariana [1 ]
Lima, Inaya [2 ]
Lopes, Ricardo Tadeu [2 ]
Nojima, Lincoln Issamu [1 ]
Sant'Anna, Eduardo Franzotti [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Pedodont & Orthodont, BR-21941617 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Nucl Instrumentat Lab, Nucl Engn Program, BR-21941617 Rio De Janeiro, RJ, Brazil
关键词
MINISCREW IMPLANTS; ORTHODONTIC ANCHORAGE; COMPUTED-TOMOGRAPHY; DENSITY; SCREWS; STRENGTH; QUALITY; TORQUE; IMPACT;
D O I
10.1016/j.ajodo.2014.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Mechanical interlocking between a mini-implant (MI) and the bone substrate reflects directly on the primary stability achieved. The purposes of this study were to evaluate MI design performance in distinct bone substrates and correlate geometric characteristics with insertion site quality. Methods: Two types of self-drilling MIs (1.6 x 8 mm) were allocated to 2 groups according to their geometric designs: Tomas system (Dentaurum, Ispringen, Germany) and Dual-Top (Rocky Mountain Orthodontics, Denver, Colo). Forty sections (8 x 10 mm) were taken from bovine pelvic ilium and pubic bone. Geometric design characteristics were evaluated using scanning electron microscope imaging and Image-Pro Insight software (Media Cybernetics, Rockville, Md). Bone quality parameters were assessed with a microcomputed tomography system, and primary stability was evaluated by insertion torque and pull-out strength. Intergroup comparisons were performed with analysis of variance and Tukey tests, and the Pearson correlation test was carried out (P < 0.05). Results: No significant difference was observed in the comparisons of the groups (Tomas: insertion torque, 12.87 N.cm; pull-out strength, 181 N; and Dual-Top: insertion torque, 9.95 N.cm; pull-out strength, 172.5 N) in the ilium. However, the Tomas group had a marked increase in insertion torque (25.08 N.cm; P < 0.05) in the pubic bone. Conclusions: MI mechanical performance differed according to bone quality parameters, indicating that certain geometric parameters may be set depending on the insertion substrate.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [41] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495
  • [42] Orthodontic mini-implant stability in different healing times before loading: A microscopic computerized tomographic and biomechanical analysis
    Zhao, Lixing
    Xu, Zhenrui
    Yang, Zhi
    Wei, Xing
    Tang, Tian
    Zhao, Zhihe
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02): : 196 - 202
  • [43] Gender and growth variation in palatal bone thickness and density for mini-implant placement
    Sumit Yadav
    Emily Sachs
    Meenakshi Vishwanath
    Kristen Knecht
    Madhur Upadhyay
    Ravindra Nanda
    Aditya Tadinada
    Progress in Orthodontics, 19
  • [44] Determination of Palatal Bone Density to Aid in Oral Mini-Implant Surgical Success
    Flores, Alicia
    Reed, James Christopher
    FASEB JOURNAL, 2016, 30
  • [45] Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults
    Baumgaertel, Sebastian
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 104 - 108
  • [46] Influence of bone density, screw size and surgical procedure on orthodontic mini-implant placement - part A: temperature development
    Moehlhenrich, S. C.
    Heussen, N.
    Modabber, A.
    Kniha, K.
    Hoelzle, F.
    Wilmes, B.
    Danesh, G.
    Szalma, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (04) : 555 - 564
  • [47] Two Different Implant Designs and Impact of Related Drilling Protocols on Primary Stability in Different Bone Densities: An In Vitro Comparison Study
    Sennerby, Lars
    Pagliani, Luca
    Petersson, Anders
    Verrocchi, Damiano
    Volpe, Stefano
    Andersson, Peter
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) : 564 - 568
  • [48] Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits
    Park, Jea-Beom
    Kim, Eun-Young
    Paek, Janghyun
    Kook, Yoon-Ah
    Jeong, Do-Min
    Cho, Il-Sik
    Nelson, Gerald
    INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014
  • [49] Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region
    Jia, Xueting
    Chen, Xing
    Huang, Xiaofeng
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (05) : 656 - 661
  • [50] A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device
    Hosein, Yara K.
    Dixon, S. Jeffrey
    Rizkalla, Amin S.
    Tassi, Ali