Influence of bone architecture on the primary stability of different mini-implant designs

被引:21
|
作者
da Cunha, Amanda Carneiro [1 ]
Marquezan, Mariana [1 ]
Lima, Inaya [2 ]
Lopes, Ricardo Tadeu [2 ]
Nojima, Lincoln Issamu [1 ]
Sant'Anna, Eduardo Franzotti [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Pedodont & Orthodont, BR-21941617 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Nucl Instrumentat Lab, Nucl Engn Program, BR-21941617 Rio De Janeiro, RJ, Brazil
关键词
MINISCREW IMPLANTS; ORTHODONTIC ANCHORAGE; COMPUTED-TOMOGRAPHY; DENSITY; SCREWS; STRENGTH; QUALITY; TORQUE; IMPACT;
D O I
10.1016/j.ajodo.2014.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Mechanical interlocking between a mini-implant (MI) and the bone substrate reflects directly on the primary stability achieved. The purposes of this study were to evaluate MI design performance in distinct bone substrates and correlate geometric characteristics with insertion site quality. Methods: Two types of self-drilling MIs (1.6 x 8 mm) were allocated to 2 groups according to their geometric designs: Tomas system (Dentaurum, Ispringen, Germany) and Dual-Top (Rocky Mountain Orthodontics, Denver, Colo). Forty sections (8 x 10 mm) were taken from bovine pelvic ilium and pubic bone. Geometric design characteristics were evaluated using scanning electron microscope imaging and Image-Pro Insight software (Media Cybernetics, Rockville, Md). Bone quality parameters were assessed with a microcomputed tomography system, and primary stability was evaluated by insertion torque and pull-out strength. Intergroup comparisons were performed with analysis of variance and Tukey tests, and the Pearson correlation test was carried out (P < 0.05). Results: No significant difference was observed in the comparisons of the groups (Tomas: insertion torque, 12.87 N.cm; pull-out strength, 181 N; and Dual-Top: insertion torque, 9.95 N.cm; pull-out strength, 172.5 N) in the ilium. However, the Tomas group had a marked increase in insertion torque (25.08 N.cm; P < 0.05) in the pubic bone. Conclusions: MI mechanical performance differed according to bone quality parameters, indicating that certain geometric parameters may be set depending on the insertion substrate.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [21] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [22] Primary migration of a mini-implant under a functional orthodontic loading
    Joseph W. Pittman
    Anand Navalgund
    Steve H. Byun
    Hechang Huang
    Albert H. Kim
    Do-Gyoon Kim
    Clinical Oral Investigations, 2014, 18 : 721 - 728
  • [23] Biomechanical and histomorphometric properties of four different mini-implant surfaces
    Yadav, Sumit
    Upadhyay, Madhur
    Roberts, Wilbur Eugene
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (06) : 627 - 635
  • [24] Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
    Bilhan, Hakan
    Bilmenoglu, Caglar
    Urgun, Aliye Ceren
    Ates, Gokcen
    Bural, Canan
    Cilingir, Altug
    Geckili, Onur
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1036 - 1040
  • [25] Comparison of histomorphometry and microradiography of different implant designs to assess primary implant stability
    Romanos, Georgios
    Damouras, Michael
    Veis, Alexander A.
    Hess, Pablo
    Schwarz, Frank
    Brandt, Silvia
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 373 - 379
  • [26] Effects of Drilling Technology on Mini-Implant Primary Stability: A Comparison of the Mechanical Drilling and Femtosecond Laser Ablation
    Zhang, Wenbin
    Alghannam, Fahad
    Zhu, Yingchao
    Zhang, Jianfei
    Wohl, Gregory R.
    Haugen, Harold K.
    Qin, Zhipeng
    Xie, Guoqiang
    Fang, Qiyin
    Shen, Steve Guofang
    FRONTIERS IN PHYSICS, 2021, 9
  • [27] Finite element analysis of mono- and bicortical mini-implant stability
    Holberg, Christof
    Winterhalder, Philipp
    Rudzki-Janson, Ingrid
    Wichelhaus, Andrea
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (05) : 550 - 556
  • [28] Bone density at interradicular sites: implications for orthodontic mini-implant placement
    Chun, Y. S.
    Lim, W. H.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2009, 12 (01) : 25 - 32
  • [29] Effect of zoledronic acid on bone healing subsequent to mini-implant insertion
    Huja, Sarandeep S.
    Kaya, Burcak
    Mo, X.
    D'Atri, Andrew M.
    Fernandez, Soledad A.
    ANGLE ORTHODONTIST, 2011, 81 (03) : 363 - 369
  • [30] Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading
    Lee, Yang-Ku
    Kim, Jong-Wan
    Baek, Seung-Hak
    Kim, Tae-Woo
    Chang, Young-Il
    ANGLE ORTHODONTIST, 2010, 80 (03) : 452 - 458