Investigation of the EMG-angle relationship in the upper-limb muscles during isometric contraction

被引:0
|
作者
Rabbi, Mohammad Fazle [1 ]
Ahamed, Nizam Uddin [2 ]
Alqahtani, Mahdi [3 ]
Altwijri, Omar [3 ]
Ghazali, Kamarul Hawari [1 ]
Sundaraj, K. [4 ]
机构
[1] Univ Malaysia Pahang, Fac Elect & Elect Engn, Pekan 26600, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Mfg Engn, Dept Mechatron Engn, Pekan 26600, Pahang, Malaysia
[3] King Saud Univ, Coll Appl Med Sci, Dept Biomed Technol, Riyadh 11472, Saudi Arabia
[4] Univ Tekn Malaysia Malaka, Dept Elect & Comp Engn, Melaka 75450, Malaysia
来源
BIOMEDICAL RESEARCH-INDIA | 2017年 / 28卷 / 06期
关键词
Electromyography; Elbow angle; Rehabilitation; ELECTROMYOGRAPHY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The relationship between EMG and elbow angle was investigated to identify the signal characteristics of upper-limb muscles during isometric contraction. The study would improve the current understanding of electrophysiological activities of the human upper limbs, which would aid the development of prosthetic arms for rehabilitation research. Subjects and methods: Ten subjects aged 22.4(+/- 1.5) years participated in this study. The electromyography signals from the biceps brachii muscle were recorded during isometric contraction. The root mean square and mean absolute value of the EMG signals were calculated and evaluated to assess the relationship between the signals and elbow angles. In addition, the force exerted by the upper limb was recorded using a dynamometer to identify more features of the relationship. Results: The results revealed that both the RMS and MAV of the EMG signals are not significantly related with the elbow angle (r(2)=0.70 and 0.21; p=0.075 and 0.43, respectively). In contrast, the force is strongly related to the elbow angle (r(2)=0.88, p=0.017). Conclusion: A stronger electrical signal was generated by the upper-limb muscles with an increase in the angle of the elbow joint, whereas a lower force was obtained with an increase in the elbow joint angle.
引用
收藏
页码:2393 / 2397
页数:5
相关论文
共 50 条
  • [31] A Robust Constrained Control of Upper-Limb Exoskeleton for Isometric Rehabilitation Exercises
    Pavia, Matteo
    Murakami, Toshiyuki
    2024 33RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, ISIE 2024, 2024,
  • [32] Adaptive weight compensation in Assistive Upper-Limb Exoskeletons: an EMG Analysis
    Salman, Nada
    Benali, Abderraouf
    2024 33RD IEEE INTERNATIONAL CONFERENCE ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION, ROMAN 2024, 2024, : 387 - 392
  • [33] Arm Abduction Angle and Contraction Intensity Effects on EMG Median Frequency During Abduction Isometric Contractions
    Timmons, Mark K.
    Stevens, Stacy M.
    Pincivero, Danny M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S268 - S268
  • [34] The Effect of Shoulder Flexion Angles on the Recruitment of Upper-extremity Muscles during Isometric Contraction
    Moon, Jeheon
    Shin, Insik
    Kang, Myoungsoo
    Kim, Yeonghun
    Lee, Kunwoo
    Park, Jaewoo
    Kim, Kyungnam
    Hong, Daehie
    Koo, Dohoon
    O'Sullivan, David
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2013, 25 (10) : 1299 - 1301
  • [35] EMG CHANGES IN RESPIRATORY AND SKELETAL-MUSCLES DURING ISOMETRIC CONTRACTION UNDER NORMOXIC, HYPOXEMIC, OR ISCHEMIC CONDITIONS
    BADIER, M
    GUILLOT, C
    LAGIERTESSONNIER, F
    JAMMES, Y
    MUSCLE & NERVE, 1994, 17 (05) : 500 - 508
  • [36] DATA REDUCTION BY PREPROCESSING OF EMG DURING DYNAMIC ISOMETRIC CONTRACTION
    KLEISSEN, RFM
    HARLAAR, RFM
    DEKREEK, JA
    ELECTROPHYSIOLOGICAL KINESIOLOGY /, 1988, 804 : 523 - 526
  • [37] A Study of EMG and EEG during Perception-Assist with an Upper-Limb Power-Assist Robot
    Kiguchi, Kazuo
    Hayashi, Yoshiaki
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 2711 - 2716
  • [38] THE PRECISION OF MOTOR CONTROL IN HUMAN JAW AND LIMB MUSCLES DURING ISOMETRIC CONTRACTION IN THE PRESENCE OF VISUAL FEEDBACK
    VANSTEENBERGHE, D
    BONTE, B
    SCHOLS, H
    JACOBS, R
    SCHOTTE, A
    ARCHIVES OF ORAL BIOLOGY, 1991, 36 (07) : 545 - 547
  • [39] Fatiguing effects of indirect vibration stimulation in upper limb muscles: pre, post and during isometric contractions superimposed on upper limb vibration
    Pujari, Amit N.
    Neilson, Richard D.
    Cardinale, Marco
    ROYAL SOCIETY OPEN SCIENCE, 2019, 6 (10):
  • [40] Masticatory and Neck Muscles' Isometric Endurance and Their Relation to Upper Limb Isometric Grip Strength in Sport Climbers-Preliminary Investigation
    Baszczowski, Michal
    Dolina, Aleksandra
    Zawadka, Magdalena
    Ginszt, Michal
    Czarnecki, Adam
    Ginszt, Agata
    Gawda, Piotr
    MEDICINA-LITHUANIA, 2024, 60 (12):