Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

被引:12
|
作者
Takahashi, Yutaka [1 ]
Vagge, Stefano [8 ,9 ]
Agostinelli, Stefano [8 ,9 ]
Han, Eunyoung [10 ]
Matulewicz, Lukasz [11 ,12 ]
Schubert, Kai [13 ]
Chityala, Ravishankar [2 ,3 ]
Ratanatharathorn, Vaneerat [10 ]
Tournel, Koen [14 ]
Penagaricano, Jose A. [10 ]
Florian, Sterzing [13 ]
Mahe, Marc-Andre [15 ]
Verneris, Michael R. [4 ,5 ,6 ]
Weisdorf, Daniel J. [7 ]
Corvo, Renzo [8 ,9 ]
Dusenbery, Kathryn E. [2 ]
Storme, Guy [14 ]
Hui, Susanta K. [1 ,2 ]
机构
[1] Univ Minnesota, Masonic Canc Ctr, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Therapeut Radiol, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Minnesota Super Comp Inst, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Div Hematol, Dept Pediat, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Div Oncol, Dept Pediat, Minneapolis, MN 55455 USA
[6] Univ Minnesota, Div Bone Marrow Transplantat, Dept Pediat, Minneapolis, MN 55455 USA
[7] Univ Minnesota, Dept Med, Minneapolis, MN 55455 USA
[8] Natl Inst Canc Res, Dept Radiat Oncol, Genoa, Italy
[9] Univ Genoa, Genoa, Italy
[10] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
[11] Maria Sklodowska Curie Mem Canc Ctr, Dept Radiat Oncol, Gliwice, Poland
[12] Inst Oncol, Gliwice, Poland
[13] Heidelberg Univ, Dept Radiat Oncol, Heidelberg, Germany
[14] Univ Ziekenhuis Brussel, Dept Radiotherapy, Brussels, Belgium
[15] Integrated Ctr Oncol Rene Gauducheau, Dept Radiat Oncol, St Herblain, France
关键词
TOTAL-BODY IRRADIATION; GUIDED TOTAL-MARROW; HEMATOPOIETIC-CELL TRANSPLANTATION; BONE-MARROW; MULTIPLE-MYELOMA; RANDOMIZED-TRIAL; LEUKEMIA; EXPERIENCE; REGIMENS; PHASE;
D O I
10.1016/j.ijrobp.2014.09.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranialecaudal, and vertical directions were 2.2 +/- 1.7 mm, 2.6 +/- 1.4 mm, and 2.7 +/- 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with >= 15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization. (C) 2015 Elsevier Inc.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [31] Deep learning promoted target volumes delineation of total marrow and total lymphoid irradiation for accelerated radiotherapy: A multi-institutional study
    Xue, Xudong
    Shi, Jun
    Zeng, Hui
    Yan, Bing
    Liu, Lei
    Jiang, Dazhen
    Wang, Xiaoyong
    Liu, Hui
    Jiang, Man
    Shen, Jianjun
    An, Hong
    Liu, An
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 123
  • [32] Implementing safe and robust Total Marrow Irradiation using Helical Tomotherapy - A practical guide
    Haraldsson, Andre
    Engellau, Jacob
    Lenhoff, Stig
    Engelholm, Silke
    Back, Sven
    Engstrom, Per E.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 162 - 167
  • [33] Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy
    Yutaka Takahashi
    Susanta K Hui
    Radiation Oncology, 8
  • [34] Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy
    Takahashi, Yutaka
    Hui, Susanta K.
    RADIATION ONCOLOGY, 2013, 8
  • [35] Dosimetric verification of dose calculation algorithm in the lung during total marrow irradiation using helical tomotherapy
    Konstanty, Ewelina
    Malicki, Julian
    Lagodowska, Katarzyna
    Kowalik, Anna
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (01) : 33 - 37
  • [36] Advances in the implementation of helical tomotherapy- based total marrow irradiation with a novel field junction technique
    Zeverino, Michele
    Agostinelli, Stefano
    Taccini, Gianni
    Cavagnetto, Francesca
    Garelli, Stefania
    Gusinu, Marco
    Vagge, Stefano
    Barra, Salvina
    Corvo, Renzo
    MEDICAL DOSIMETRY, 2012, 37 (03) : 314 - 320
  • [37] Implementation of Total Marrow Irradiation With Helical Tomotherapy; Clinical Experiences and Report on Organ Sparing in Pediatric Patients
    Engellau, Jacob
    Haraldsson, Andre
    Engstrom, Per
    Lenhoff, Stig
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 101 (04): : 1006 - 1007
  • [38] Helical Tomotherapy for Craniospinal Irradiation: What We Have Learned from a Multi-Institutional Study
    Du, D.
    Han, C.
    Chen, J.
    Perez-Andujar, A.
    Lee, B.
    Kaprealian, T.
    Low, D.
    Qi, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3563 - 3563
  • [39] Feasibility Study of a Novel and Efficient Treatment Planning Technique for Total Body Irradiation and Total Marrow Irradiation On Conventional Linacs
    Han, C.
    Dandapani, S.
    Wong, J.
    Liu, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Evaluation and improvement the safety of total marrow irradiation with helical tomotherapy using repeat failure mode and effects analysis
    Jiuling Shen
    Xiaoyong Wang
    Di Deng
    Jian Gong
    Kang Tan
    Hongli Zhao
    Zhirong Bao
    Jinping Xiao
    An Liu
    Yunfeng Zhou
    Hui Liu
    Conghua Xie
    Radiation Oncology, 14