Development of a CFD model for simulating vehicle cabin indoor air quality

被引:49
|
作者
Chang, Tong-Bou [1 ]
Sheu, Jer-Jia [2 ]
Huang, Jhong-Wei [2 ]
Lin, Yu-Sheng [1 ]
Chang, Che-Cheng [1 ]
机构
[1] Natl Chiayi Univ, Dept Mech & Energy Engn, Chiayi, Taiwan
[2] Southern Taiwan Univ Sci & Technol, Dept Mech Engn, Tainan, Taiwan
关键词
IAQ; Air leakage ventilation; Vehicle HVAC; THERMAL COMFORT; HUMID CLIMATE; VENTILATION; ENVIRONMENT; HOT;
D O I
10.1016/j.trd.2018.03.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As the level of CO2 within the vehicle cabin increases, the risk of accidents as a result of driver drowsiness and a slowing of the reactions also increases. Accordingly, a CFD simulation model was developed in this study to explore the effects of outdoor air ventilation rate on vehicle cabin indoor air quality and the amount of outdoor air required for each person in a vehicle. The results show that using the outdoor air supply rate recommendations of ASHRAE Standard 62.1 (i.e. 2.5 1/s per person) the mean CO2 concentrations in the cabin are around 2850 ppm. The results also show that using the outdoor air supply rate recommendations of 4.01/s per person for improved human wellbeing, the corresponding mean CO2 concentrations in the cabin are around 1810 ppm. Moreover, the present study found that an outdoor fresh air flow rate of 9.21/s per passenger was sufficient to reduce the carbon dioxide concentration within the cabin to a safe value of 1000 ppm. Furthermore, an outdoor fresh air flow rate of 3.61/s per passenger resulted in a carbon dioxide concentration of around 2000 ppm.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [21] Grey model of indoor air quality
    Zhu, C
    Li, N
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2807 - 2812
  • [22] AN INDOOR AIR-QUALITY MODEL
    KUMAR, A
    KOTHARI, AM
    ENVIRONMENTAL PROGRESS, 1990, 9 (03): : A8 - A9
  • [23] CAD-CFD Analysis for Power Cabin of Vehicle
    Lv, Liangdong
    Bi, Xiaoping
    Zhou, Guoyin
    2010 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS 1-3, 2010, : 282 - 285
  • [24] Air Quality Monitoring and Detection System in Vehicle Cabin Based on Internet of Things
    Waworundeng, Jacquline
    Adrian, Priana Sari
    3RD INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (ICORIS 2021), 2021, : 716 - 721
  • [25] Vehicle cabin air quality monitor using gas sensors for improved safety
    Galatsis, K
    Wlodarski, W
    Li, YX
    Kalantar-zadeh, K
    COMMAD 2000 PROCEEDINGS, 2000, : 65 - 68
  • [26] Indoor air quality test and air distribution CFD simulation in hospital consulting room
    Yao, Jiali
    Zhong, Jiachen
    Yang, Ning
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 33 - 37
  • [27] Assessment of Indoor Air Quality in Buildings using CFD: A Brief Review
    Shree, Venu
    Marwaha, Bhanu M.
    Awasthi, Pamita
    INTERNATIONAL JOURNAL OF MATHEMATICAL ENGINEERING AND MANAGEMENT SCIENCES, 2019, 4 (05) : 1154 - 1168
  • [28] Cabin air quality: An overview
    Rayman, RB
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2002, 73 (03): : 211 - 215
  • [29] Aircraft cabin air quality
    Cox, JE
    Miro, CR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1997, 39 (04): : 22 - 22
  • [30] INDOOR AIR QUALITY RELATED TO TOTAL MINIMUM AIR VENTILATION RATE, AIR QUALITY AND CFD SIMULATIONS OF POLLUTION DISTRIBUTION
    Nagy, Richard
    Kosicanova, Danica
    12th International Multidisciplinary Scientific Geoconference, SGEM 2012, Vol. IV, 2012, : 529 - 536