INDOOR AIR QUALITY RELATED TO TOTAL MINIMUM AIR VENTILATION RATE, AIR QUALITY AND CFD SIMULATIONS OF POLLUTION DISTRIBUTION

被引:0
|
作者
Nagy, Richard [1 ]
Kosicanova, Danica [1 ]
机构
[1] Tech Univ Kosice, Inst Bldg & Environm Engn, Fac Civil Engn, Kosice, Slovakia
关键词
Air ventilation rate; infiltration; mechanical ventilation; CFD simulations; experimental measurements; ventilation system; air distribution scheme; mixing ventilation; displacement ventilation; confluent ventilation; personal ventilation; air distribution index; carbon dioxide;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The air ventilation rates defined in Standard STN EN 15 251: 2007 present air change rate in which the objective benefit of proper selection of ventilation system and air distribution scheme is lost (erased) in relation to IAQ [1,2]. With help of sensory evaluation in research the total minimum ventilation rate was estimated. It was reason how to determine major boundary condition (air quantity = air ventilation rate) for minimizing of responsibility size of air quantity (quantitative component of ventilation) and maximize the impact of the choice of distribution scheme and the distribution element (qualitative component of ventilation) for transfer and distribution of pollutants in research. The total air ventilation rate for next experimental measurements was established as the intersection of three air ventilation rates according to research harmonogram. This air ventilation rate was necessary to supply to occupant to experimental classroom and also as input value to CFD simulations. Within the frame of air infiltration measurements (Description: older research, air infiltration quantification, 500 measurements for 6 categories of building types) that is presented in this paper, this value of air infiltration was determinated for an experimental classroom (Type of Buildings - Schools) at value level n(INF)=0,3[1/h] respectively q(INF)=16[litre/s]. It is average air infiltration value for Schools Buildings [3,4]. It was necessary to ensured increased air ventilation rate n(MECH)=1,0[1/h] respectively q(MECH)=53,3[litre/s] by mechanical ventilation system. These values were used and reflected in the experimental measurements and CFD simulations.
引用
收藏
页码:529 / 536
页数:8
相关论文
共 50 条
  • [1] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1983, 177 (06): : 571 - 571
  • [2] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    [J]. ENVIRONMENT INTERNATIONAL, 1983, 9 (02) : 153 - 156
  • [3] On indoor air pollution and indoor air quality control
    Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Chongqing University, Chongqing 400045, China
    不详
    [J]. Chongqing Jianzhu Daxue Xuebao, 2007, 6 (108-112):
  • [4] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    [J]. ATMOSPHERE, 2022, 13 (10)
  • [5] Indoor air pollution: How to improve the quality of that air?
    Lavaud, F.
    Dutau, G.
    [J]. REVUE FRANCAISE D ALLERGOLOGIE, 2016, 56 (04): : 341 - 343
  • [6] Indoor air quality, distribution systems and energy simulations
    Nagy, R.
    Senitkova, I.
    [J]. CHALLENGES, OPPORTUNITIES AND SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2010, : 873 - 878
  • [7] Indoor air quality test and air distribution CFD simulation in hospital consulting room
    Yao, Jiali
    Zhong, Jiachen
    Yang, Ning
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 33 - 37
  • [8] Ventilation for acceptable indoor air quality
    [J]. ASHRAE Standard, 2007, (62.1-2007): : 1 - 41
  • [9] Effect of ventilation on indoor air quality
    Chen Jin-hua
    Duan Sheng-hui
    Zheng Ping
    Zhao Wen-jiang
    Zi Li-mei
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 48 - 52
  • [10] INDOOR AIR-QUALITY AND VENTILATION
    BERGLUND, MB
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (02): : 47 - 47