INDOOR AIR QUALITY RELATED TO TOTAL MINIMUM AIR VENTILATION RATE, AIR QUALITY AND CFD SIMULATIONS OF POLLUTION DISTRIBUTION

被引:0
|
作者
Nagy, Richard [1 ]
Kosicanova, Danica [1 ]
机构
[1] Tech Univ Kosice, Inst Bldg & Environm Engn, Fac Civil Engn, Kosice, Slovakia
关键词
Air ventilation rate; infiltration; mechanical ventilation; CFD simulations; experimental measurements; ventilation system; air distribution scheme; mixing ventilation; displacement ventilation; confluent ventilation; personal ventilation; air distribution index; carbon dioxide;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The air ventilation rates defined in Standard STN EN 15 251: 2007 present air change rate in which the objective benefit of proper selection of ventilation system and air distribution scheme is lost (erased) in relation to IAQ [1,2]. With help of sensory evaluation in research the total minimum ventilation rate was estimated. It was reason how to determine major boundary condition (air quantity = air ventilation rate) for minimizing of responsibility size of air quantity (quantitative component of ventilation) and maximize the impact of the choice of distribution scheme and the distribution element (qualitative component of ventilation) for transfer and distribution of pollutants in research. The total air ventilation rate for next experimental measurements was established as the intersection of three air ventilation rates according to research harmonogram. This air ventilation rate was necessary to supply to occupant to experimental classroom and also as input value to CFD simulations. Within the frame of air infiltration measurements (Description: older research, air infiltration quantification, 500 measurements for 6 categories of building types) that is presented in this paper, this value of air infiltration was determinated for an experimental classroom (Type of Buildings - Schools) at value level n(INF)=0,3[1/h] respectively q(INF)=16[litre/s]. It is average air infiltration value for Schools Buildings [3,4]. It was necessary to ensured increased air ventilation rate n(MECH)=1,0[1/h] respectively q(MECH)=53,3[litre/s] by mechanical ventilation system. These values were used and reflected in the experimental measurements and CFD simulations.
引用
收藏
页码:529 / 536
页数:8
相关论文
共 50 条
  • [41] Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building
    Tong, Zheming
    Chen, Yujiao
    Malkawi, Ali
    Adamkiewicz, Gary
    Spengler, John D.
    ENVIRONMENT INTERNATIONAL, 2016, 89-90 : 138 - 146
  • [42] Ventilation for better indoor air quality - Selected papers from the Indoor Air 2005 Conference
    Department of Mechanical Engineering, The University of Hongkong, Hongkong, Hong Kong
    不详
    Int. J. Vent., 2006, 3 (273):
  • [43] Indoor air quality
    1998, (71):
  • [44] Indoor air quality
    Youakim, Sami
    BRITISH COLUMBIA MEDICAL JOURNAL, 2019, 61 (03): : 131 - 131
  • [45] Indoor air quality
    Ding, T.
    Liu, Z.
    Livestock Environment VII, Proceedings, 2005, : 257 - 262
  • [46] INDOOR AIR QUALITY
    DUNHAM, SB
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1976, 26 (02): : 105 - 105
  • [47] Numerical Simulation of Air Distribution's Impact on Indoor Air Quality
    Zhang, Min
    Zhao, Bin
    3RD INTERNATIONAL CONFERENCE ON APPLIED ENGINEERING, 2016, 51 : 1 - 6
  • [48] Editorial - Ventilation and indoor air quality in residential dwellings
    Zhang, Tengfei
    Pei, Jingjing
    BUILDING AND ENVIRONMENT, 2019, 148 : 198 - 199
  • [49] Ventilation for good indoor air quality and energy efficiency
    Awbi, Hazim B.
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 277 - 286
  • [50] Improving indoor air quality by increased ventilation effectiveness
    Rojeski, Jr., Peter
    Journal of Architectural Engineering, 1999, 5 (01) : 25 - 29