INDOOR AIR QUALITY RELATED TO TOTAL MINIMUM AIR VENTILATION RATE, AIR QUALITY AND CFD SIMULATIONS OF POLLUTION DISTRIBUTION

被引:0
|
作者
Nagy, Richard [1 ]
Kosicanova, Danica [1 ]
机构
[1] Tech Univ Kosice, Inst Bldg & Environm Engn, Fac Civil Engn, Kosice, Slovakia
关键词
Air ventilation rate; infiltration; mechanical ventilation; CFD simulations; experimental measurements; ventilation system; air distribution scheme; mixing ventilation; displacement ventilation; confluent ventilation; personal ventilation; air distribution index; carbon dioxide;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The air ventilation rates defined in Standard STN EN 15 251: 2007 present air change rate in which the objective benefit of proper selection of ventilation system and air distribution scheme is lost (erased) in relation to IAQ [1,2]. With help of sensory evaluation in research the total minimum ventilation rate was estimated. It was reason how to determine major boundary condition (air quantity = air ventilation rate) for minimizing of responsibility size of air quantity (quantitative component of ventilation) and maximize the impact of the choice of distribution scheme and the distribution element (qualitative component of ventilation) for transfer and distribution of pollutants in research. The total air ventilation rate for next experimental measurements was established as the intersection of three air ventilation rates according to research harmonogram. This air ventilation rate was necessary to supply to occupant to experimental classroom and also as input value to CFD simulations. Within the frame of air infiltration measurements (Description: older research, air infiltration quantification, 500 measurements for 6 categories of building types) that is presented in this paper, this value of air infiltration was determinated for an experimental classroom (Type of Buildings - Schools) at value level n(INF)=0,3[1/h] respectively q(INF)=16[litre/s]. It is average air infiltration value for Schools Buildings [3,4]. It was necessary to ensured increased air ventilation rate n(MECH)=1,0[1/h] respectively q(MECH)=53,3[litre/s] by mechanical ventilation system. These values were used and reflected in the experimental measurements and CFD simulations.
引用
下载
收藏
页码:529 / 536
页数:8
相关论文
共 50 条
  • [21] Indoor Air Pollution, Related Human Diseases, and Recent Trends in the Control and Improvement of Indoor Air Quality
    Vinh Van Tran
    Park, Duckshin
    Lee, Young-Chul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (08)
  • [22] CFD simulations of effects of recirculation mode and fresh air mode on vehicle cabin indoor air quality
    Chang, Tong-Bou
    Lin, Yu-Sheng
    Hsu, Yi-Tian
    ATMOSPHERIC ENVIRONMENT, 2023, 293
  • [23] THE EFFECT OF VENTILATION AND AIR-POLLUTION ON PERCEIVED INDOOR AIR-QUALITY IN 5 TOWN HALLS
    ZWEERS, T
    SKOV, P
    VALBJORN, O
    MOLHAVE, L
    ENERGY AND BUILDINGS, 1990, 14 (03) : 175 - 181
  • [24] THE EFFECT OF VENTILATION AND AIR-POLLUTION ON PERCEIVED INDOOR AIR-QUALITY IN 5 TOWN HALLS
    ZWEERS, T
    SKOV, P
    VALBJORN, O
    MOLHAVE, L
    ENERGY AND BUILDINGS, 1991, 17 (03) : 255 - 255
  • [25] EFFECTIVENESS OF INDOOR AIR QUALITY IMPROVEMENT WITH OUTDOOR AIR FOR BUILDING VENTILATION
    Wang, J.
    Zhang, X.
    Zhou, X.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 417 - 421
  • [26] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [27] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [28] BUILDING VENTILATION AND INDOOR AIR-QUALITY
    BERK, JV
    AMERICAN CERAMIC SOCIETY BULLETIN, 1980, 59 (03): : 327 - 327
  • [29] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [30] Ventilation strategies to improve indoor air quality
    Luo, Q
    Tang, G
    Huang, W
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3313 - 3317