Effective dose equivalent estimates in diagnostic radiology with single dosimetry

被引:8
|
作者
Michel, R
Perle, SC
机构
[1] Univ Calif San Diego, La Jolla, CA 92093 USA
[2] ICN Pharmaceut, Dosimetry Div, Costa Mesa, CA 92626 USA
来源
HEALTH PHYSICS | 2000年 / 79卷 / 02期
关键词
operational topics; effective nose; dosimetry; diagnostic radiology;
D O I
10.1097/00004032-200008001-00006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In many external exposure situations dose estimates obtained from personal monitors significantly overestimate the Effective Dose Equivalent (EDE). This occurs particularly when the body is not uniformly exposed due to the irradiation conditions or due to protective shielding (i.e., lead apron) of portions of the body (NCRP 1995). Many numerical relationships between monitoring data and EDE have been proposed to perform more accurate dose estimates (Gill et al. 1980; Faulkner and Harrison 1988; Webster 1989; Niklason et al. 1994; Berger et al. 1995). Also, organizations such as the Conference of Radiation Control Program Directors (CRCPD) the National Council on Radiation Protection and Measurements (NCRP) and the Electric Power Research Institute (EPRT) have published recommendations on this subject (CRCPD 1995; NCRP 1995; EPRI 1998). Before implementing the use of any of the proposed relationships, they should be thoroughly reviewed so that proper practices ale chosen and monitoring data are properly evaluated. It is also important for each facility to be aware of the regulatory requirements in their state such as if the methodology is approved for use, which method and for whom can the EDE be applied. The United States Nuclear Regulatory Agency (NRC) does not currently permit dose weighting for any of its licensees. The EPRI study performed in 1997 was initiated by the NRC to determine how viable dose weighting would be, and for which NRC licensee population. This paper discusses numerical relationships for external exposure in diagnostic radiology for estimating EDE in a single-monitor program.
引用
收藏
页码:S17 / S19
页数:3
相关论文
共 50 条
  • [31] Thermoluminescent dosimetry in veterinary diagnostic radiology
    Hernandez-Ruiz, L.
    Jimenez-Flores, Y.
    Rivera-Montalvo, T.
    Arias-Cisneros, L.
    Mendez-Aguilar, R. E.
    Uribe-Izquierdo, P.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 44 - 47
  • [32] Diagnostic radiology dosimetry: Status and trends
    Rivera-Montalvo, T.
    APPLIED RADIATION AND ISOTOPES, 2016, 117 : 74 - 81
  • [33] Patient dosimetry in paediatric diagnostic radiology
    Borisova, R.
    Ingilizova, Ch.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 155 - 159
  • [34] Equivalent dose to the fetus from occupational exposure of pregnant staff in diagnostic radiology
    Osei, EK
    Kotre, CJ
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883): : 629 - 637
  • [35] Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures
    Osei, Ernest K.
    Barnett, Rob
    JOURNAL OF RADIOLOGICAL PROTECTION, 2009, 29 (03) : 361 - 376
  • [36] Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures
    Osei, E. K.
    Barnett, R.
    MEDICAL PHYSICS, 2009, 36 (09) : 4305 - 4305
  • [37] EVALUATION OF EFFECTIVE DOSE EQUIVALENT FROM DIAGNOSTIC SPECIAL PROCEDURES
    SADAGOPAN, G
    SUPE, SJ
    HEALTH PHYSICS, 1985, 48 (06): : 824 - 825
  • [38] ESTIMATES OF THE EFFECTIVE DOSE EQUIVALENT, HE, IN POSITRON EMISSION TOMOGRAPHY STUDIES
    HUDA, W
    SANDISON, GA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 17 (3-4): : 116 - 120
  • [39] The effect of single grain luminescence characteristics on single aliquot equivalent dose estimates
    Stone, A. E. C.
    Bailey, R. M.
    QUATERNARY GEOCHRONOLOGY, 2012, 11 : 68 - 78
  • [40] THE ESTIMATION OF OCCUPATIONAL EFFECTIVE DOSE IN DIAGNOSTIC-RADIOLOGY WITH 2 DOSIMETERS
    NIKLASON, LT
    MARX, MV
    CHAN, HP
    HEALTH PHYSICS, 1994, 67 (06): : 611 - 615