THE ESTIMATION OF OCCUPATIONAL EFFECTIVE DOSE IN DIAGNOSTIC-RADIOLOGY WITH 2 DOSIMETERS

被引:95
|
作者
NIKLASON, LT
MARX, MV
CHAN, HP
机构
[1] HARVARD UNIV, SCH MED, DEPT RADIOL, BOSTON, MA 02114 USA
[2] UNIV MICHIGAN HOSP, DEPT RADIOL, ANN ARBOR, MI 48109 USA
来源
HEALTH PHYSICS | 1994年 / 67卷 / 06期
关键词
DOSIMETRY; EXPOSURE; OCCUPATIONAL; RADIATION; IONIZING; RADIATION PROTECTION;
D O I
10.1097/00004032-199412000-00003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield.
引用
收藏
页码:611 / 615
页数:5
相关论文
共 50 条
  • [1] ESTIMATION OF EFFECTIVE DOSE IN DIAGNOSTIC-RADIOLOGY
    HISWARA, E
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 51 (02) : 141 - 142
  • [2] ESTIMATION OF EFFECTIVE DOSE EQUIVALENT TO STAFF IN DIAGNOSTIC-RADIOLOGY
    FAULKNER, K
    HARRISON, RM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 83 - 91
  • [3] EFFECTIVE DOSE EQUIVALENTS, HE, IN DIAGNOSTIC-RADIOLOGY
    HUDA, W
    BISSESSUR, K
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 998 - 1003
  • [4] REQUIREMENTS FOR DOSIMETERS USED IN DIAGNOSTIC-RADIOLOGY
    SELBACH, HJ
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 25 - 29
  • [5] MEASUREMENT OF EFFECTIVE DOSE EQUIVALENT IN DIAGNOSTIC-RADIOLOGY
    FAULKNER, K
    HARRISON, RM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 792 - 793
  • [6] EXPOSURE AND ORGAN DOSE ESTIMATION IN DIAGNOSTIC-RADIOLOGY
    MCGUIRE, EL
    DICKSON, PA
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 913 - 916
  • [7] Effective dose estimation in diagnostic radiology with two dosimeters: Impact of the 2007 recommendations of the ICRP
    von Boetticher, Heiner
    Lachmund, J.
    Hoffmann, W.
    [J]. HEALTH PHYSICS, 2008, 95 (03): : 337 - 340
  • [8] THE EFFECTIVE USE OF DIAGNOSTIC-RADIOLOGY
    ROBERTS, CJ
    [J]. JOURNAL OF THE ROYAL COLLEGE OF PHYSICIANS OF LONDON, 1984, 18 (01): : 62 - 65
  • [9] DOSE REDUCTION IN DIAGNOSTIC-RADIOLOGY
    WIATROWSKI, WA
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 24 - 25
  • [10] ORGAN DOSE IN PEDIATRIC DIAGNOSTIC-RADIOLOGY
    FEARON, T
    VUCICH, J
    ECKERMAN, K
    YALCINTAS, G
    CRISTY, M
    [J]. MEDICAL PHYSICS, 1986, 13 (05) : 782 - 782